• 제목/요약/키워드: Milking

검색결과 237건 처리시간 0.025초

젖소 사양기술의 자동화를 위한 연구 II. 체온 측정 방법을 통한 질병자동 진단 시스템 (Studies on Automatization of Dairy Cattle Farming II. Automatic System for Detection of Diseased Cattle by Taking Body Temperature)

  • 김용준;유일정;정길도;한병성;김동원;김명순
    • 한국임상수의학회지
    • /
    • 제15권2호
    • /
    • pp.450-454
    • /
    • 1998
  • These studies were performed to find out the possibility of automatic detection of the diseased animal with fever by farmers themselves. Firstly, the body temperature of 331 dairy cows was investigated according to major disease symptoms manifested. Secondly, AD 590 thermometer was used to take the teat temperature of the milking cows to determine the possibility of automatic taking of body temperature while milking. The temperatures of scapha of ear and coccygeal artery part were also taken fur the non-milking dairy cows and Korean native cowl 1. The average body temperature of dairy cows associated with respiratory diseases puerperal disease, or mastitis was higher than normal temperature denoting respectively 39.8,39.6, and $39.3{\circ}C.2.$ The teat temperaure of the milking dairy cows with fever($39.5~39.6{\circ}C$) and the cows with mastitis was respectively 1.02 and 0.56${\circ}C$ higher than that of normal cows. 3. The average teat temperature taken by AD 590 was 33.91, 34.93, and 34.50${\circ}C$ in normal milking dairy cows, cows with fever(39.5~39.6${\circ}C$), and cows with mastitis, respectively. 4. The mean temperatures at scapha and coccygeal part of non-milking dairy cows and Korean native cows were 35.62 and 36.63${\circ}C$, respectively. It was concluded that AD 590 thermometer would be usable for the farmers to automatirally detect the body temperature of dairy cows while milking and subsquently to find the diseased cow with fever and that the scapha of ear and coccygeal artery part of the cattle could be the body parts of simply detecting body temperature of non-milking cattle.

  • PDF

홀스타인 착유우의 착유시간, 착유속도 및 착유량에 대한 유전모수 추정 (Genetic Parameters for Milking Duration, Milk Flow and Milk Yield Per Milking in Holstein Dairy Cattle)

  • 안병석;주종철;전병순;박성재;백광수;박수봉
    • Journal of Animal Science and Technology
    • /
    • 제48권4호
    • /
    • pp.487-492
    • /
    • 2006
  • 본 연구는 우군의 일일 유량에 대한 비유형질의 특성을 분석하고자 하였으며 공시된 젖소는 농촌진흥청 축산연구소에서 사육된 착유우로서 2005년 11월부터 2006년 4월까지 1일 2회 착유를 하는 우군의 자료를 이용하였다. 시험축은 하나의 우군으로 동일한 사양조건에 의하여 관리된 종모우 66두를 가지는 착유우 154두에서 수집된 기록 12,561개를 분석하였다. 공시축의 평균유기는 139.7일, 평균산차는 1.9산, 착유당 평균유량 13kg을 나타내었다. 평균 비유속도는 최고 비유속도의 64% 수준으로 측정되었다. 비유지속시간, 최고비유속도, 평균비유속도, 착유당 평균유량에 대하여 오후 착유 보다 오전 착유가 높게 나타났고, 산차간에서는 비유지속시간을 제외하고 산차증가와 함께 증가하는 경향이었다. 비유지속시간, 최고비유속도, 평균비유속도 및 착유당 평균 유량에 대한 유전력은 각 0.49, 0.70, 0.58, 0.36으로 비교적 높게 추정되었다. 한편 비유지속시간과 비유속도간에는 부의 유전상관이, 비유지속시간과 착유당 유량간에는 정의 상관이, 최고비유속도에 대한 평균비유 속도(0.87)와 착유당 유량(0.23)은 정의 상관을 보였고, 평균비유속도와 착유당 유량간(0.30)에도 정의 유전상관을 보였다. 결론적으로 비유속도는 유량과 함께 증가하였으나 비유지속시간과는 부의 관계를 보였으나 보다 의미 있는 유전적 특성을 파악하기 위하여 더 많은 두수를 이용한 연구가 필요할 것으로 사료된다.

일반목장과 로봇착유 목장에서 분리한 세균과 Staphylococcus aureus의 항생제 감수성 비교 (Comparison of pathogens and antimicrobial susceptibility of Staphylococcus aureus isolated from conventional and robotic milking herds)

  • 이성환;김두
    • 대한수의학회지
    • /
    • 제54권1호
    • /
    • pp.49-52
    • /
    • 2014
  • This study was conducted to compare the patterns of mastitic pathogens and the antimicrobial susceptibility of Staphylococcus (S.) aureus from conventional milking (CM) and robotic milking (RM) dairy herds. To accomplish this, the minimum inhibitory concentrations of 14 antimicrobial agents were tested against S. aureus by the microdilution method. Regardless of the milking system, S. aureus, coagulase negative staphylococcus, and Streptococcus uberis were isolated. Additionally, significant differences in the antimicrobial susceptibility of S. aureus isolates between RM and CM farms were only observed in response to tetracycline.

Treatment of milking parlor wastewater containing tetracycline by magnetic activated sludge and contact oxidation process

  • Gaowa, Gaowa;Sakai, Yasuzo;Xie, Xiaonan;Saha, Mihir Lal;Ihara, Ikko
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.32-36
    • /
    • 2021
  • Milking parlor wastewater contains not only high concentrations of organic compounds, but often animal antibiotics. To discharge the antibiotics to public water area cause problem of antibiotics resistant bacteria. Magnetic separation was applied into improvement of milking parlor wastewater treatment process. A new process, composed of a magnetic activated sludge (MAS) process and a contact oxidation (CO) process, was proposed in this study. This process was evaluated by the simulated milking parlor wastewater (4500 mg/L CODCr and 10 mg/L tetracycline) using a bench scale experimental setup. As a result, the process was able to removed 97% CODCr as well as 94% tetracycline. The MLVSS (mixed liquor volatile suspended solids) concentration of MAS was maintained at 12000 mg/L without excess sludge drawing. This process was considered to be useful as treatment process for milking parlor wastewater in which waste-milk including antibiotics is often discharged.

Characteristics of milk fever and mastitis following different milking method and preventive calcium injection performed during the colostrum period in dairy cattle

  • Jeon, Ryounghoon
    • 한국동물생명공학회지
    • /
    • 제35권3호
    • /
    • pp.273-278
    • /
    • 2020
  • The milk fever and mastitis that occur during the colostrum period in dairy cattle cause great damage in the dairy industry by causing a rapid decline in the cattle's health and decreasing milk production. In order to prevent this, gradual milking (GM), calcium injection with gradual milking (CG), and calcium injection with complete milking (CC) methods are used. However, differences in effectiveness between these methods have not been established. Therefore, this study was conducted to determine the effects of each preventive method on milk fever and mastitis. The results of this study showed that while there was a significant negative correlation of GM with milk fever and mastitis (r = -0.657, p < 0.05), there was no correlation of CG and CC with milk fever and mastitis. The incidence of milk fever was significantly lower in CG and CC than in GM (p < 0.05) but no differences in the incidence of mastitis were observed between the three groups. No significant differences in the rate of recovery from milk fever and mastitis were observed between the three groups. The recurrence rate of milk fever was significantly higher in CG and CC than in GM (p < 0.05), though no differences in the recurrence rate of mastitis were observed. This study showed an inverse relationship between the incidence rates of milk fever and mastitis when calcium injection was not used during the colostrum period. When calcium injections were used, the incidence of milk fever was reduced without affecting the incidence of mastitis regardless of the milking method, but the recurrence rate of milk fever was increased. The results of this study would be useful for controlling blood calcium concentrations and establishing efficient milking strategy in order to effectively prevent milk fever and mastitis in dairy cattle during the colostrum period.

로봇 착유기의 착유컵 자동착탈을 위한 착유우의 유두위치 조사분석 (Position Analysis of Cow Teats for Teat-cup Attachment System on Robotic Milking System)

  • 권두중;김웅;이대원
    • 한국축산시설환경학회지
    • /
    • 제8권3호
    • /
    • pp.159-164
    • /
    • 2002
  • The distance between teats of each head on twenty heads of holstein was measured in Nation Livestock Research Institute of Rural Development Administration to find design variables on the teat-cup attachment system of the auto-milking system before milking. The distance between teats was tested by the steps for milk producing in the morning and evening. The results from this study is summarized as follow. 1 The maximum and minimum length between front teats were 297mm and 112mm respectively, the maximum and minimum length between rear teats were 231mm and 36mm and the maximum and minimum length between left front and left rear were 220 and 84mm. And the maximum length of right front and right rear were 205mm and 90mm. A relative position of the each teats was asymmetric. 2. The size of teats, the length between front teats, and the length between rear teats by lactating period were very much changed for its milking. 3. The design variables on the teat-cup attachment system was found by the length between each teats tested. Since the position of teat-cup is changed by milking environment for a cow to milk, the design variables should be considered to be asymmetric area between four teat of COW.

  • PDF

로봇 착유시스템을 위한 착유컵 착탈모듈 개발 (Development of Teat-cups Attachment Module for Robot Milking System)

  • 김웅;이대원
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.179-184
    • /
    • 2005
  • The purpose of this study was the development of teat-cup attachment module for robot milking system. The teat-cups attachment module was controlled on the two dimensional space independently, Each teat cup of an end effector was independently controlled via two axis control based on the position information data obtained from the image processing system. This system was developed install of all 4 teat cups at the same time after adjusting positions of each teat sequentially. The individual motion system was operated using two servo motors for the high speed of teat position adjustment. The errors fur the individual motion system of teat cups were maximum 1.0mm, minimum 0.0mm, and average 0.6mm. The operating time for adjusting the teat cups position required about 1.0 second. It is envisaged that teat cups attachment module can be applicate to milking robot being developed in consideration of the experiment results for the teat cups operation accuracy and the actuation speed of servo motors.

로봇 착유시스템을 위한 다관절 매니퓰레이터 개발 (Development of a Multi-joint Robot Manipulator for Robot Milking System)

  • 김웅;이대원
    • Journal of Biosystems Engineering
    • /
    • 제30권5호
    • /
    • pp.293-298
    • /
    • 2005
  • The purpose of this study was the development of a multi-joint robot manipulator for milking robot system. The multi-joint robot manipulator was controlled by 5 drivers with driver controller through the position information obtained from the image processing system. The robot manipulator to automatically attach each teat cup to the teats of a milking cow was developed and it's motion was accurately measured with error rate. Results were as follows. 1. Maximum errors in position accuracy were 4mm along X-axis, 4.5mm along Y-axis and 0.9mm along Z-axis. Absolute distance errors were maximum 4.8mm, minimum 2.7mm, and average 3.6mm. 2. Errors of repeatability were maximum 3.0mm along X-axis, 3.0mm along Y-axis, and 0.5mm along Z-axis. Distance error values were maximum 3.2mm, minimum 2.2mm, and average 2.5mm. It is envisaged that multi-joint robot manipulator can be applicate to milking robot system being developed in consideration of the experiment results.

SOME MECHANICAL FACTORS AFFECTING MACHINE MILKING CHARACTERISTICS UNDER SEMI-ARID CONDITION

  • Ali, A.K.A.;Farah, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권3호
    • /
    • pp.475-480
    • /
    • 1992
  • The effect of mechanical factors and season of the year on milking characteristics (milk yield, time of milking, rate of milk flow, stripping time and tripping milk) were studied on 26 Holstein Friesian cows, raised under Saudi Arabia environmental conditions. Cows were in the third and fourth lactation and reached the peak. Cows milked twice a day with equal intervals. Three vacuum levels (34, 38 and 42 cfm) and two pulsation ratios were used to form six vacuum-pulsation combinations. The study was carried during two seasons Autumn-Winter (S1) and Spring-Summer (S2). After absorbing the cow equations least square analysis was used to analyze the data. Vacuum level 38 cfm and pulsation ratio 70:30 was the best among all combinations of vacuum level-pulsation ratio. No significant effect (p < .01) for season, up to the seventh half minute, on the rate of milk flow. However, season of the year has a significant effect on total milk yield, stripping time and stripping milk.

RESULTS AND FURTHER DEVELOPMENT OF AN AUTOMATIC MILKING SYSTEM

  • Toth, L.;Bak, J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.779-790
    • /
    • 1993
  • A prototype of the feeding-milking robot was developed in the Hungarian Institute of Agricultural Engineering in 1988-89. Before starting with the operation tests the cleaning system had to be elaborated . The cleaning system has two parts. Those are the complete cleaning of the system, producing a practically sterile state, as well as flushing through the milking device between milking of two cows. Separate electronic sensor development was necessary for both system which can connect to the control system of the robot. To clean the system pneumatic air input was applied. As an effect of the local adjustment of the electronic control system optimal flow conditions can be formed what is more favourable comparing to the earlier solutions of cleaning due to the mechanical effect. In the flushing through overpressure air is applied. The air and the cleaning liquid input duration can be adjusted to the local conditions. The electronic control unit can be connected to the electric ircuits of robot.

  • PDF