• 제목/요약/키워드: Mig6

검색결과 45건 처리시간 0.027초

모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구 (Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard)

  • 신용철;이광용;이나루;오세민;강성규;문영한;이기라
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF

An analysis of missed injuries in patients with severe trauma

  • EunGyu, Ju;Sun Young, Baek;Sung Soo, Hong;Younghwan, Kim;Seok Hwa, Youn
    • Journal of Trauma and Injury
    • /
    • 제35권4호
    • /
    • pp.248-254
    • /
    • 2022
  • Purpose: To analyze the data of trauma patients with undetected injuries at the time of initial resuscitation during the primary and secondary surveys. Methods: We retrospectively reviewed the medical records of 807 patients who were hospitalized at the National Trauma Center, Seoul, Korea from June 1, 2019 to June 30, 2021. Results: In trauma patients with an Injury Severity Score ≥16 accounted for 27.5% in the non-missed injury group (non-MIG), but this rate was considerably higher at 71.2% in MIG. The mean hospitalization longer in MIG (50.90±39.56) than in non-MIG (24.74±26.11). The proportion of patients with missed injuries detected through tertiary trauma survey (TTS) was 28 patients (23.5%) within 24 hours, 90 patients (75.6%) after 24 hours to before discharge. The majority of missed injuries were fractures (82.4%) and ligament tears (8.4%), which required consultation with the orthopedic department. The final diagnoses of missed injuries were confirmed by computed tomography (44.5%), magnetic resonance imaging (19.3%), X-ray (19.3%), bone scan (11.8%), and physical examination (5.0%). Conclusions: TTS is considered a useful process for detecting missed injuries that were not identified at the time of initial resuscitation in the primary and secondary surveys. In the future, to detect missed injuries quickly, it is necessary to develop a suitable TTS program for each trauma center. In addition, further research is needed to verify the effectiveness of the protocolized TTS and survey chart to improve the effectiveness of TTS.

Effects of Solution Treatment Temperatures on Microstructure and Mechanical Properties of TIG-MIG Hybrid Arc Additive Manufactured 5356 Aluminum Alloy

  • Zuo, Wei;Ma, Le;Lu, Yu;Li, Shu-yong;Ji, Zhiqiang;Ding, Min
    • Metals and materials international
    • /
    • 제24권6호
    • /
    • pp.1346-1358
    • /
    • 2018
  • A novel additive manufacturing method with TIG-MIG hybrid heat source was applied for fabricating 5356 aluminum alloy component. In this paper the microstructure evolution, mechanical properties and fracture morphologies of both as-deposited and heat-treated component were investigated, and how these were affected by different heat-treated temperature. The as-deposited microstructure showed dominant equiaxed grains with second phase, and the size of them is coarse in the bottom region, medium in the middle region and fine in the top region owing to different thermal cycling conditions. Compared with as-deposited microstructure, the size of grain becomes large and second phases gradually dissolve in the matrix as heat-treated temperature increase. Different microstructures determine the mechanical properties of component. Results show that average ultimate tensile strength enhances from 226 to 270 MPa and average microhardness increases from 64.2 to 75.3 HV0.1 but ductility decreases from 33 to 6.5% with heat-treated temperature increasing. For all components, the tensile properties are almost the same in the vertical direction (Z) and horizontal direction (Y) due to equiaxed grains, which exhibits isotropy, and the mechanisms of these are analyzed in detailed. In general, the results demonstrate that hybrid arc heat source has the potential to fabricate aluminum alloy component.

1.0Cr-1.0Mo-0.25V 터어빈 로터강의 열영향부 연화층이 크립 파단 특성에 미치는 영향 -Part I : 크립 파단 수명 - (Effect of HAZ Softening Zone on Creep Rupture Properties of 1.0Cr-1.0Mo-0.25V Turbine Rotor Steels - Part I : Creep Rupture Life-)

  • 오영근
    • Journal of Welding and Joining
    • /
    • 제15권1호
    • /
    • pp.92-100
    • /
    • 1997
  • 손상된 ASTM A-470 class 8 고압 증기 터어빈 로터강의 수명 연장을 위해 보수 용접이 행하여졌다. SAW 용접부의 미세경도 측정결과 모재의 경도는 VHN 253이었으나 모재에 근접한 열영향부의 경도는 VHN 227로 떨어졌다. 이와 같이 경도가 떨어진 영역을 "연화층"이라 정의하였으며 약 0.5-0.6mm의 크기를 나타내었다. 한편 크립 파단 시험시 파괴는 연화층 부근에서 일어났으며 593.deg. C와 19Ksi(132 Mpa)에서 파단시간은 772.4hr이었다. 연화층의 크기를 줄이기 위해서 MIG 및 TIG 용접이 행하여졌는데 연화층 크기는 MIG의 경우 0.3-0.4mm이고, TIG의 경우에는 입열량의 크기에 따라 0부터 0.4mm의 크기를 나타내었다. 그러나 크립 파단시간은 연화층 크기가 작아질수록 감소하였다. 특히 TIG 용접부의 경우 크립 파단시간은 입열량과 밀접한 관계를 나타내었는데 입열량이 클수록 파단시간은 길어졌다. 대부분의 파괴는 ICHAZ에서 발생되었으나 입열량이 감소함에 따라 파단부는 CGHAZ으로 이동하였다. 파단면은 tearing과 dimple을 갖는 입내파괴를 나타내었다.파괴를 나타내었다.

  • PDF

Mechanistic insights into differential requirement of receptor dimerization for oncogenic activation of mutant EGFR and its clinical perspective

  • Cho, Jeonghee
    • BMB Reports
    • /
    • 제53권3호
    • /
    • pp.133-141
    • /
    • 2020
  • The epidermal growth factor receptor (EGFR), a member of the ErbB family (EGFR, ErbB2, ErbB3 and ErbB4), plays a crucial role in regulating various cellular responses such as proliferation, differentiation, and survival. As a result, aberrant activation of EGFR, mostly mediated through different classes of genomic alterations occurring within EGFR, is closely associated with the pathogenesis of numerous human cancers including lung adenocarcinoma, glioblastoma, and colorectal cancer. Thus, specific suppression of oncogenic activity of mutant EGFR with its targeted drugs has been routinely used in the clinic as a very effective anti-cancer strategy in treating a subset of tumors driven by such oncogenic EGFR mutants. However, the clinical efficacy of EGFR-targeted therapy does not last long due to several resistance mechanisms that emerge in the patients following the drug treatment. Thus, there is an urgent need for the development of novel therapeutic tactics specifically targeting mutant EGFR with the focus on the unique biological features of various mutant EGFR. Regarding this point, our review specifically emphasizes the recent findings about distinct requirements of receptor dimerization and autophosphorylation, which are critical steps for enzymatic activation of EGFR and signaling cascades, respectively, among wildtype and mutant EGFR and further discuss their clinical significance. In addition, the molecular mechanisms regulating EGFR dimerization and enzymatic activity by a key negative feedback inhibitor Mig6 as well as the clinical use for developing potential novel drugs targeting it are described in this review.

MIG-WELDING OF MAGNESIUM ALLOYS WITH PARTICULAR CONSIDERATION OF DROP DETACHMENT

  • Wohlfahrt, H.;Rethmeier, M.;Wiesner, S.
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.94-100
    • /
    • 2002
  • During the last years, great progress has been made in the fields of welding power sources and filler materials for the MIG-welding of magnesium alloys. This advice resulted in a better welding process, md, therefore, in highly improved welding results. Furthermore the gap between short-circuiting- and spray-arc-trunsfer could be closed by the triggered short-circuiting- and the short-circuiting-arc with pulse overlay. A crucial contribution to the welding process is the energy input into the filler material. Many problems result from the physical properties of magnesium, for instance its narrow interval between melting point 600$^{\circ}C$ and vaporization point 1100$^{\circ}C$. The energy input into the filler material has to be regulated in such a way that the wire will melt but not vaporize. For th is reason, special characteristics of power sources hue been examined and optimized with the help of high-speed-photographs of the welding process with particular consideration of the drop detachment. An important improvement of the weld seam profile has been achieved by using filler material of only 1.2 mm in diameter. The experiments hue been made with 2.5 mm thick extruded profiles of AZ31 and AZ6l. The results of tensile testing showed strength values of 80 to 100% of the base metal. B ending angles up to 60$^{\circ}$ have been reached. The fatigue strength under reversed bending of the examined magnesium alloys after welding reaches 50% of the strength of the base metal. When the seam reinforcement is ground of the fatigue strength can be raised up to 75% of the base metal.

  • PDF

AL5083 합금에 대한 Plasma-GMA 용접에서 분산분석을 이용한 공정변수의 특성 평가 (Weldability Evaluation in Plasma-GMA Hybrid Welding for Al-5083 Using Analysis of Variance)

  • 정진수;이종중;이희근;박영환
    • Journal of Welding and Joining
    • /
    • 제32권1호
    • /
    • pp.28-33
    • /
    • 2014
  • In this paper, I-butt welding with 6mm thickness using Plasma-GMA welding was carried out. And weld characteristics of the Al-5083 aluminium alloy for Plasma-GMA hybrid welding was evaluated. The orthogonal experimental design was used to investigate the influence of plasma-MIG welding parameters such as plasma current, wire feeding rate, MIG-welding voltage and welding speed on the weld bead geometry and tensile strength using the ANOVA(Analysis of Variation). Then we conducted evaluation of contribution for process parameters. ANOVA results show that bead dimensions are affected by wire feeding speed, welding voltage and welding speed and tensile strength is mainly affected by welding speed and plasma arc current. Tensile strength was decreased by rise in plasma welding current because GMA welding current was decreased by plasma arc.

[논문 철회] 친환경 레져선박에 적용되는 Al 5083 합금의 인장특성 및 열응력에 미치는 용접조건의 영향 ([Retracted] The Effect of Welding Conditions on Tensile Characteristics and Thermal Stress of Al 5083 Alloy Applied to Co-environmental Leisure Ships)

  • 문병영;이기열;김규선
    • 대한조선학회논문집
    • /
    • 제51권6호
    • /
    • pp.548-555
    • /
    • 2014
  • As a considerable, experimental approach, an Auto-carriage type of $CO_2$ welding machine and a MIG(Metal Inert Gas) welding robot under inert gas atmosphere were utilized in order to realize Al 5083 welding applied to hull and relevant components of green Al leisure ships. This study aims at investigating the effect of welding conditions(current, voltage, welding speed, etc) on thermal deformation that occurs as welding operation and tensile characteristics after welding, by using Al 5083, non-ferrous material, applied to manufacturing of co-environmental Al leisure ships. With respect to welding condition to minimize the thermal deformation, 150A and 16V at the wire-feed rate of 6mm/sec were acquired in the process of welding Al 5083 through an auto carriage type of $CO_2$ welding feeder. As to tensile characteristics of Al 5083 welding through a MIG welding robot, most of tensile specimens showed the fracture behavior on HAZ(Heat Affected Zone) located at the area joined with weld metal, except for some cases. Especially, for the case of the Al specimen with 5mm thickness, 284.62MPa of tensile strength and 11.41% of elongation were obtained as an actual allowable tensile stress-strain value. Mostly, after acquiring the optimum welding condition, the relevant welding data and technical requirements might be provided for actual welding operation site and welding procedure specification(WPS).

새로운 풀-브리지 소프트 스위칭 PWM 인버터를 이용한 용접기용 DC-DC 컨버터의 개발 (Development of Arc Welding Machines DC-DC Converter using A Novel Full-Bridge Soft Switching PWM Inverter)

  • 권순걸;문상필
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.26-33
    • /
    • 2008
  • 본 연구에서는 일반적으로 용접기의 전원장치로 사용되어지는 풀-브리지 회로에 1개의 스위치와 1개의 무손실스너버 부분 공진 커패시터로 구성된 간단한 액티브 보조 부분 공진 스너버를 추가한 새로운 풀-브리지 소프트 스위칭 PWM DC-DC 컨버터를 제안하였다. 제안한 풀-브리지 소프트 스위칭 DC-DC 컨버터 회로는 각 액티브 스위치에 인가된 전압이 DC 버스 라인 전압의 1/2로 되기 때문에 AC 400(V)계 상용전원 라인에 적용할 경우에도 600(V)내압의 스위칭 소자(IGBT)가 적용 가능하며, 기존 회로의 DC버스 라인 스위치에 발생되는 도통 손실을 저감하여 고주파 변압기의 1차측의 전류가 2차측보다 작아지는 저 전압, 대전류 직류 출력을 얻어 수 있었다. 그리고 모든 영역에서 ZCS/ZVS 동작함으로써 저전압, 대전류 직류 출력의 스위칭 전원 장치에 있어 고주파, 고효율, 고출력을 실현할 수 있다. 이러한 모든 사항은 시뮬레이션과 실험 결과로부터 도출하였으며, 제안한 회로의 단점을 보완할 경우에는 차세대형 TIG MIG MAG 아크 용접기용 전원으로 용이할 것으로 판단된다.