• Title/Summary/Keyword: Microwave process

Search Result 539, Processing Time 0.031 seconds

Treatment Cost Comparison and Development of Sustainability Indices for Microwave Soil Remediation of TPHs(Total Petroleum Hydrocarbons)

  • Kim, Dong Uk;Koo, Ja-Kong
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.5
    • /
    • pp.11-15
    • /
    • 2015
  • The three processes of 1) high- & low-temperature microwave heatings, 2) the soil washing, and 3) the thermal desorption processes in soil remediation are analysed on the treatment cost data for 2003-2012 years. The cost of microwave heating method with at temperature 500-700℃, for 30 minutes, and at 4-6 kW is approximately 10 $/ton (13,000 ₩) due to the deep through heating of micro-wave, the soil washing with chemicals is about 80 $/ton (85,000 ₩) due to the chemicals & duration, and the thermal desorption process is around 40 $/ton (41,000 ₩) from the less efficiency. Furthermore the sustainability has been assessed, and suggestions are made. 1) Green; the minimal environmental footprint, 2) Growth; the least cost, 3) Shared; the social & environmental justice, 4) Smart; the microwave characteristics of deep through irradiation & heating, and 5) Mutuality; the flexibility of the technology. More additives including water, the government support, and public relation are suggested realizing the microwave in this condition is not harmful to human beings.

Effective Thermal Inactivation of the Spores of Bacillus cereus Biofilms Using Microwave

  • Park, Hyong Seok;Yang, Jungwoo;Choi, Hee Jung;Kim, Kyoung Heon
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.7
    • /
    • pp.1209-1215
    • /
    • 2017
  • Microwave sterilization was performed to inactivate the spores of biofilms of Bacillus cereus involved in foodborne illness. The sterilization conditions, such as the amount of water and the operating temperature and treatment time, were optimized using statistical analysis based on 15 runs of experimental results designed by the Box-Behnken method. Statistical analysis showed that the optimal conditions for the inactivation of B. cereus biofilms were 14 ml of water, $108^{\circ}C$ of temperature, and 15 min of treatment time. Interestingly, response surface plots showed that the amount of water is the most important factor for microwave sterilization under the present conditions. Complete inactivation by microwaves was achieved in 5 min, and the inactivation efficiency by microwave was obviously higher than that by conventional steam autoclave. Finally, confocal laser scanning microscopy images showed that the principal effect of microwave treatment was cell membrane disruption. Thus, this study can contribute to the development of a process to control food-associated pathogens.

Analysis of Energy Consumption for Microwave Drying in PC Pellet (PC 펠렛의 마이크로웨이브 건조를 위한 에너지 효율 분석)

  • Lee, Hyun Min;Kim, Jae Kyung;Jeon, Euy Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.44-48
    • /
    • 2021
  • Semiconductor inspection equipment makes components using materials with insulating properties for functional inspection including current and voltage of semiconductor parts. A representative insulating material is plastic, and plastic is made of a component through an injection process using plastic pellet. When plastic pellets contain excessive moisture, problems such as performance degradation and product surface defects occur. To prevent this, pre-drying is essential, and the heat convective type is the most applied. However, the heat convective type has a problem of low consumption efficiency and a long drying time. Recently, many studies have been conducted on a drying method using microwaves due to high energy efficiency. In this paper, drying was performed using a microwave for drying PC pellets. Energy consumption and drying efficiency analyzed by set up an experimental apparatus of heat convective, microwave, and hybrid(heat convective + microwave) types. It was confirmed that energy consumption and drying efficiency were high when drying using microwaves, and it was confirmed that the hybrid method improved drying performance compared to the heat convective method. It is expected that the research results of this paper can be used as basic data for drying plastic pellets using microwave.

Microwave-Assisted Extraction of Effective Constituents from Ginseng (마이크로파를 이용한 인삼으로부터 유효성분의 추출)

  • Lee, Dong-Won;Park, Young-Sin;Kim, Dok-Chan
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.427-433
    • /
    • 2005
  • The use of the microwave-assisted process for the extraction of effective constituents from ginseng was investigated at various operating conditions. The influence of solvent (ethanol-water, 50% v/v) to ginseng ratio, particle size and applied microwave power on the efficiency of extraction was examined. The microwave extraction system used was custom manufactured so that the intensity of microwave may be varied by using anode-voltage controller. It was found that the ratio of 6 : 1 (vol/mass) gave a good extraction efficiency. Small particle size gave high yield but it caused difficulties in the separation of solvent from the sludge. The higher power was no guarantee of the efficient extraction yield. The more important factor than the employed power was the adequate temperature under sufficient contact time. Using deionized-water as swelling agent, the degree of swelling of ginseng by microwave heating and conventional heating in water-bath was also studied. It was observed that the microwave heating enhanced the swelling much more than the conventional heating. It is believed that this enhanced swelling was responsible for the rapid microwave-assisted extraction rate.

Comparative Study on Microwave Probes for Plasma Density Measurement by FDTD Simulations

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.218.1-218.1
    • /
    • 2014
  • In order to measure the absolute plasma density, various probes are proposed and investigated and microwave probes are widely used for its advantages (Insensitivity to thin non-conducting material deposited by processing plasmas, High reliability, Simple process for determination of plasma density, no complicate assumptions and so forth). There are representative microwave probes such as the cutoff probe, the hairpin probe, the impedance probe, the absorption probe and the plasma transmission probe. These probes utilize the microwave interactions with the plasma-sheath and inserted structure (probe), but frequency range used by each probe and specific mechanisms for determining the plasma density for each probe are different. In the recent studies, behaviors of each microwave probe with respect to the plasma parameters of the plasma density, the pressure (the collision frequency), and the sheath width is abundant and reasonably investigated, whereas relative diagnostic characteristics of the probes by a comparative study is insufficient in spite of importance for comprehensive applications of the probes. However, experimental comparative study suffers from spatially different plasma characteristics in the same discharge chamber, a low-reproducibility of ignited plasma for an uncertainty in external discharge parameters (the power, the pressure, the flow rate and so forth), impossibility of independently control of the density, the pressure, and the sheath width as well as expensive and complicate experimental setup. In this paper, various microwave probes are simulated by finite-different time-domain simulation and the error between the input plasma density in FDTD simulations and the measured that by the unique microwave spectrums of each probe is obtained under possible conditions of plasma density, pressure, and sheath width for general low-temperature plasmas. This result shows that the each probe has an optimum applicable plasma condition and reliability of plasma density measurement using the microwave probes can be improved by the complementary use of each probe.

  • PDF

Drying Characteristics of Soil by Microwave (Microwave에 의한 흙의 건조 특성 고찰)

  • Cho, Doohwan;Oh, Myounghak;Park, Junboum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.5
    • /
    • pp.5-12
    • /
    • 2011
  • Water content is one of the significant engineering properties of soil for predicting the behavior of soil matrix. Conventional drying oven can be widely used to obtain the values by drying the soil specimens for 16 to 24 hours at $105^{\circ}C$. Although a number of experimental data has been accumulated for the conventional method of drying soil for water contents, shortcomings of the method are still hard to overcome such as long drying time for in situ use and the difficulty of taking prompt actions against emergency cases. Recently, ASTM and JGS have established microwave oven drying techniques for obtaining water contents to cope with those problems. And the reliability evaluation study has been also performed on the microwave oven drying for water contents. Feasibility study of the microwave oven drying was performed to confirm the process of the technique with Jumunjin sand, kaolinite, bentonite, weathered granite soil, and organic soil. Investigation was also conducted on the factors affecting and enhancing the reliability of the technique.

Direct Microwave Sintering of Poorly Coupled Ceramics in Electrochemical Devices

  • Amiri, Taghi;Etsell, Thomas H.;Sarkar, Partha
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.390-397
    • /
    • 2022
  • The use of microwaves as the energy source for synthesis and sintering of ceramics offers substantial advantages compared to conventional gas-fired and electric resistance furnaces. Benefits include much shorter processing times and reaching the sintering temperature more quickly, resulting in superior final product quality. Most oxide ceramics poorly interact with microwave irradiation at low temperatures; thus, a more complex setup including a susceptor is needed, which makes the whole process very complicated. This investigation pursued a new approach, which enabled us to use microwave irradiation directly in poorly coupled oxides. In many solid-state electrochemical devices, the support is either metal or can be reduced to metal. Metal powders in the support can act as an internal susceptor and heat the entire cell. Then sufficient interaction of microwave irradiation and ceramic material can occur as the sample temperature increases. This microwave heating and exothermic reaction of oxidation of the support can sinter the ceramic very efficiently without any external susceptor. In this study, yttria stabilized zirconia (YSZ) and a Ni-YSZ cermet support were used as an example. The cermet was used as the support, and a YSZ electrolyte was coated and sintered directly using microwave irradiation without the use of any susceptor. The results were compared to a similar cell prepared using a conventional electric furnace. The leakage test and full cell power measurement results revealed a fully leak-free electrolyte. Scanning electron microscopy and density measurements show that microwave sintered samples have lower open porosity in the electrode support than conventional heat treatment. This technique offers an efficient way to directly use microwave irradiation to sinter thin film ceramics without a susceptor.

A Method for Determining the Sandstone Porosity by Using a Microwave Oven (마이크로웨이브 오븐을 이용한 사암의 공극률 산출 방법)

  • Woo, Seulgi;Kim, Jinhoo
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.150-160
    • /
    • 2017
  • In order to determine the porosity of rock, the 'standard test method for porosity and density of rock' proposed by the Korean Society for Rock Mechanics is commonly used. However, the standard test method, which uses a drying oven, takes 8 to 24 hours to complete the test in taking samples out of the oven every four hours and measuring the weight of the specimen. To complement these disadvantages, we devised a method for measuring rock porosity by using a microwave oven. The devised method reduced the cause of errors and the inconvenience occurred in the process of weighing samples by constructing a weight monitoring system, which monitors the drying process. A suitable heating/pause time was set up to maintain the temperature of sample below $105{\pm}3^{\circ}C$ in drying process, and an alarm system was implemented in order to stop drying process when the weight change of the rock sample is within 0.1% of the initial weight. The porosity was determined from the dry weight of the sample, which was obtained by the curve fitting of weight monitoring data. Then, the porosities obtained by using the microwave oven were compared with those obtained by the standard test method. Test results using sandstone samples showed that the porosities obtained by a microwave oven was similar to those obtained by the standard method and the porosity difference between two methods was as large as 0.4%. In addition, repeated porosity measurement using the same specimen showed that the standard deviation of the porosity, which reflects the precision of the measurement was as good as 0.23%. Therefore, a microwave oven porosity measurement system can give the porosity of rock samples with high reliability.

Analysis of the Causes of Deformation of Packaging Materials Used for Ready-to-Eat Foods after Microwave Heating (즉석편의 식품용 포장재의 전자레인지 가열에 의한 변형 원인 분석)

  • Yoon, Chan Suk;Hong, Seung In;Cho, Ah Reum;Lee, Hwa Shin;Park, Hyun Woo;Lee, Keun Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.63-69
    • /
    • 2015
  • The aim of this study was to investigate the deformation of packaging materials used for ready-to-eat (RTE) foods after the retort process and microwave heating. From the multilayer films consisting of polyethylene terephthalate (PET), polyamide (PA), and cast polypropylene (CPP) in a stand-up pouch form used for RTE foods, some deformation of the CPP layer, which was in direct contact with the food, was observed after the retort process and microwave heating. The damage was more severely caused by microwave heating than by the retort process. This may be attributed to diverse factors including the non-uniform heating in a microwave oven, the sorption of oil into the packaging film, and the different characteristics of food components such as viscosity, salt and water content. The development of heat-resistant packaging materials and systems suitable for microwave heating of RTE foods is required for the safety of consumers.

Study on characteristics of board prepared by microwave drying process of coal bottom ash and vermiculite (바텀애쉬를 이용한 흡음 내장재 개발에 관한 연구)

  • Jun, Hyun Chul;Kim, Geug Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.3
    • /
    • pp.135-142
    • /
    • 2017
  • In this study, we prepared the board of vermiculite materials utilizing coal bottom ash from the Western thermal power stations in Korea and obtained experimental data in applications for building interior materials with the characteristics of sound absorption. To produce the mixture materials of vermiculite and coal bottom ash, we used a microwave drying process. In addition, a ball milling process was used to produce particles of coal bottom ash with a uniform size of $65{\mu}m$. When the board made from mixture materials of vermiculite and coal bottom ash were produced with bottom ash sulfur concentrations of 5, 10 wt%, maximum bending loads were analyzed. These experimental results would contribute much to fundamental data essential to the recycling technology of coal bottom ash.