• Title/Summary/Keyword: Microvascular

Search Result 446, Processing Time 0.024 seconds

Effect of 4-hexylresorcinol on Blood Coagulation and Healing of Injured Vessel in a Rat Model

  • Park, Yong-Tae;Park, Si-Yeok;Kim, Min-Keun;Kim, Seong-Gon;Park, Young-Wook;Kwon, Kwang-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.284-293
    • /
    • 2013
  • Purpose: For reconstruction of craniomaxillofacial defects caused by tumor, trauma, infection etc, free flap transplantation with microvascular surgery is a very useful method. Thrombus formation at the anastomosis site is the major cause of graft failure. 4-Hexylresorcinol (4-HR) is generally known as an antiseptic and antiparasitic agent. This study was conducted in order to evaluate the effect of 4-HR on blood coagulation in vitro. In addition, we investigated thrombus formation and endothelial repair of an injured vessel in an animal model. Methods: In the in vitro experiment, we compared blood coagulation time between the 4-HR treated group and normal blood. Thirty rats were used for in vivo animal experiments. After exposure of the right femoral vein, a micro vessel clamp was placed and the femoral vein was intentionally cut. Microvascular anastomosis was performed on all rats using 10-0 nylon under microscopy. The animals were divided into two groups. In the experimental group (n=15), 4-HR (250 mg/kg) mixed with olive oil (10 mL/kg) was administered per os daily. Animals in the control group (n=15) were given olive oil only. The animals were sacrificed at three days, seven days, and fourteen days after surgery and rat femoral vein samples were taken. Vascular patency and thrombus formation were investigated just before sacrifice. Histologic analysis was performed under a microscope. Results: Results of an in vitro blood coagulation test showed that coagulation time was delayed in the 4-HR treated group. The results obtained from an in vivo 4-HR administered rat model showed that the patency of all experimental groups was better at thirty minutes, seven days, and fourteen days after microvascular anastomosis than that of the control group at seven and fourteen days after anastomosis, and the amount of thrombus in the experimental groups was much less than that of the control group. Endothelial repair was observed in the histologic analysis. Conclusion: Findings of this study demonstrated that blood coagulation was delayed in the vitro 4-HR treated group. In addition, good vascular patency, anti-thrombotic effect, and repair of venous endothelial cells were observed in the vivo 4-HR administered rat group.

STUDY OF PATENCY RATE IN VARIABLE MICROVASCULAR ANASTOMOSIS (다양한 방법으로 적용한 미세혈관문합술간의 개존율연구)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.5
    • /
    • pp.349-357
    • /
    • 2003
  • Several microvascular anastomotic techniques have been described with methodical effectiveness, patency rates, healing state of microscopic findings. This experimental study presents the comparison of three types of arterial microvascular anastomotic techniques: end-to-end(ETE) anastomosis, end-in-end(EIE) anastomosis, and continuous technique. Sixty male Sprague-Dawley rats, 60 femoral arteries were used for this study. Twenty rats per each technique were used and sacrificed at post-operation 1 day, 3 days, a week, 2 weeks for scanning electromicroscopic findings. The patency was monitored by miniDoppler throughout total experimental periods. The anastomotic time on each method was measured to compare the technical effectiveness. The final results were as follows: 1. The anastomotic time for the end-in-end technique was significantly shorter than another techniques. The average time for each technique was measured as 15 minutes on EIE technique, 20 minutes on continuous technique and 25 minutes on ETE technique. 2. The patency rate for the end-in-end technique at 2 weeks also was superior to another techniques. The patency rate for each technique was demonstrated as 90 % on EIE technique, 85 % on ETE technique and 80 % on continuous technique. 3. The scanning electromicroscopic findings on healing condition of vessel endothelium during the observation period showed that the end results of EIE technique, ETE technique and continuous technique in sequence were good. The end-in-end technique proved to be the superior with regard to anastomotic time and patency rate when compared to end-to-end technuqe, so EIE techniqe might be well available for the case of large discrepancy of vessel size. The patency rate, microscopic healing findings in continuous technique were seen as the lowest level among the three anastomotic techniques, therefore the application of continuous technique was recommended only on the inevitable case.

EEFFECTS OF TOPICAL AND INTRAVENOUS HEPARIN ON THROMBOSIS OF MICROVASCULAR ANASTOMOSES (미세혈관문합시 헤파린의 국소 및 전신 투여가 혈전 형성에 미치는 영향)

  • Kim, Sung-Youl;Ryu, Seong-Hee;Park, Hong-Ju;Oh, Hee-Kyun;Ryu, Sun-Youl;Kim, Ok-Joon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.232-238
    • /
    • 2003
  • This study was performed to evaluate the effect of topical and intravenous heparin on thrombosis and patency in the microvascular anastomosis of the traumatized veins. Nine white rabbits weighing about 2 kg were used. After exposure of both femoral veins, the veins were crushed by the jaws of smooth needle holder in order to create a thrombosis model. Transectional incision was made in the vein. The animals were then divided into 3 groups based on the administration method of heparin: 1) Experimental Group I, topical irrigation of lumen with heparin saline solution (n=6); 2) Experimental Group 2, topical irrigation of lumen with heparin saline solution and intravenous injection of heparin (0.75 mg/kg) via the marginal ear vein for 3 days; 3) Control Group, topical irrigation of lumen with saline solution (n=6). The patency was evaluated with empty-and-refill test and thrombus formation was judged by surgical microscope. The results were as follows: 1. Thirty minutes after microvascular anastomosis, the patency of all Experimental Groups was better than Control group. However, there was no significant difference among groups. 2. Three days after anastomosis, the patency of all Experimental Groups was much more improved than that of Control Group (P<0.05). There was no significant difference between Experimental Group 1 and 2. 3. Three days after anastomosis, the amount of thrombus in all Experimental Groups was much less than that of Control Group (P<0.05). 4. In histologic findings a lot of luminal thrombus were observed around sutured area in Control Groups. Few luminal thrombus was observed in all Experimental Groups. Mild necrosis in the vessel wall was observed around sutured area in all specimens. These results indicate that topical irrigation of heparin may improve the patency and inhibit the formation thrombus in the microvascular anastomosis of the traumatized veins.

Evaluation of Anastomotic Strength and in-vitro Degradability with Microvascular Anastomosis Coupler Based on Injection Molding Condition made by Biodegradable Polycaprolactone(PCL) (생체분해성 폴리카프로락톤(PCL) 미세혈관 문합커플러의 사출성형조건에 따른 문합강도 및 in-vitro 분해능 평가)

  • Ahn, Geun-Seon;Han, Gig-Bong;Oh, Seung-Hyun;Park, Jong-Woong;Kim, Cheol-Woong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.167-177
    • /
    • 2013
  • The use of mechanical anastomosis coupler instead of sutures has been increasing in microvascular anastomosis surgery. However, non-biodegradable anastomosis coupler has problems such as not only inflammatory reaction but also remaining permanently in operation wound. Therefore, we fabricated biodegradable anastomosis coupler using injection molding process to overcome the limitation of non-biodegradable anastomosis coupler. In various injection molding process conditions, the shrinkage was calculated with different cylinder temperatures and injection molding pressures and anastomotic strength was measured. As a result, changes in shrinkage hole part larger than the pin part. In addition, the shrinkage in the cylinder at higher temperatures increase. However, the higher the injection pressure, shrinkage tends to decrease, respectively. In-vitro degradation behavior of PCL anastomotic coupler evaluated for 12 weeks, water uptake was increased and molecular weight was accompanied by a reduction in mass of the biological degradation and reduction of anastomotic strength was confirmed. However, decreased levels of anastomotic strength enough to exceed the requirements of preclinical surgery, PCL microvascular anastomosis coupler suitable candidate materials that could identify.