• Title/Summary/Keyword: Microsensor Packaging

Search Result 2, Processing Time 0.019 seconds

A Magnetic Microsensor based on the Hall Effect in an AC Microplasma (극미세 교류 플라즈마 내에서의 홀 효과를 이용한 마이크로 자기센서)

  • Seo, Young-Ho;Han, Ki-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1266-1272
    • /
    • 2003
  • This paper presents a new class of magnetic microsensors based on the Hall effect in AC microplasma. In the theoretical study, we develop a simple model of the plasma Hall sensor and express the plasma Hall voltage as a function of magnetic field, plasma discharge field, pressure, and electrode geometry. On this basis, we have designed and fabricated magnetic microsensors using AC neon plasma. In the experiment, we have measured the Hall voltage output of the plasma microsensors for varying five different conditions, including the frequency and the magnitude of magnetic field, the frequency and the magnitude of plasma discharge voltage, and the neon pressure. The fabricated magnetic microsensors show a magnetic field sensitivity of 8.87${\pm}$0.18㎷/G with 4.48% nonlinearity.

Development of Battery-free SAW Integrated Microsensor for Real Time Simultaneous Measurement of Humidity and $CO_2$ component (습도와 $CO_2$ 농도의 실시간 동시감지를 위한 무전원 SAW 기반 집적 센서 개발)

  • Lim, Chun-Bae;Lee, Kee-Keun;Wang, Wen;Yang, Sang-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • A 440MHz wireless and passive surface acoustic wave (SAW) based chemical sensor was developed on a $41^{\circ}YX\;LiNbO_3$ piezoelectric substrate for simultaneous measurement of $CO_2$ gas and relative humidity (RH) using a reflective delay line pattern as the sensor element. The reflective delay line is composed of an interdigital transducer (IDT) and several shorted grating reflectors. A Teflon AF 2400 and a hydrophilic $SiO_2$ layer were used as $CO_2$ and water vapor sensitive films. The coupling of mode (COM) modeling was conducted to determine optimal device parameters prior to fabrication. According to simulation results, the device was fabricated and then wirelessly measured using the network analyzer. The measured reflective coefficient $S_{11}$ in the time domain showed high signal/noise (S/N) ratio, small signal attenuation, and few spurious peaks. In the $CO_2$ and humidity testing, high sensitivity ($2^{\circ}/ppm$ for $CO_2$ detection and $7.45^{\circ}/%$RH for humidity sensing), good linearity and repeatability were observed in the $CO_2$ concentration ranges of $75{\sim}375ppm$ and humidity levels of $20{\sim}80%$RH. Temperature and humidity compensations were also investigated during the sensitivity evaluation process.

  • PDF