• 제목/요약/키워드: Microscopic test

검색결과 529건 처리시간 0.027초

치과 보철용 금속 합금의 마찰 마멸 특성 (Tribological Characteristics of Dental Metal Alloys)

  • 김종훈;최원식
    • Tribology and Lubricants
    • /
    • 제29권4호
    • /
    • pp.235-241
    • /
    • 2013
  • The tribological characteristics of dental metal alloys and zirconia were studied by carrying out a friction and wear performance test. In this study, a pin-on-disk-type tester was used and dead weight was employed as the normal load applied to the test specimen. The friction coefficient of dental metal alloys was investigated in terms of their weight and sliding velocity. Microscopic observations were carried out on worn surfaces of specimens. The results indicated that among all metal alloys, Super-A had the highest friction coefficient. Super-A had the lowest amount of wear among all metal alloys, and the amount of wear increased in the following order: Crown & Bridge, Porcelain, and Partial. Crown & Bridge had the best friction coefficient, but the hardness of Crown & Bridge was lower than that of Porcelain and Partial. Experimental measurement results indicated that the disk weight before and after the experiment was the same.

캐모마일 추출액 염색직물의 염색성 및 항균성 (The Dyeing Properties and Antibacterial Activity of Fabrics Dyed with Camomile Extract)

  • 박영희
    • 한국의류학회지
    • /
    • 제29권8호
    • /
    • pp.1188-1195
    • /
    • 2005
  • The effects on the dyeing properties and antibacterial activity of fabrics dyed with camomile extract were analyzed. As the results obtained, the surface color of all the dyed fabric was tinged with the yellow of the bright color tone. In the test results of durability, the durability to sunlight of the dyed fabric of both cotton and silk showed from 2nd grade to 3rd grade. The durability to laundry of the dyed fabric of both cotton and silk showed relatively higher grade of 4th-5th. The durability to synthetic sweat of all the fabrics except fer the dyed fabric mordanted with $CuSO_4{\cdot}5H_2O$ showed the relatively good result of 3rd- 5th grade. The durability to friction and dry cleaning of all the dyed fabrics showed the excellent result of 4th-5th grade. In the test results of antibiosis, the dyed fabric of cotton showed the decrease rate of $50\%$ to Staphylococcus aureus and the decrease rate of $70\%$ to Klebsiella pneumoniae. The dyed fabric of silk showed the significant effect with Microscopic growth to the mold bacillus Aspergillus niger.

Corrosion Inhibition of Steel for Water Pipe Line by Adding a Non-Toxic Spearmint Extracts

  • Farooq, Hina;Kim, Jae-Yeon;Lee, Do-Il;Byeon, Jai-Won
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권2호
    • /
    • pp.122-128
    • /
    • 2017
  • Purpose: To investigate the corrosion inhibition effect of the natural spearmint oil extracted from Mentha Spicata plants on 304 stainless steel in different concentrations of hydrochloric acid. Method: The anti-corrosive effect has been investigated in 0.5m, 1m and 2m HCl using weight loss test and electrochemical polarization method as a function of inhibitor concentration and immersion time in strong chloride environment. The surface morphology was analysed by scanning electron microscopy (SEM). Results: The corrosion rate of steel decreased and inhibition efficiency increased with the increase in inhibitor concentration. Microscopic evaluation revealed significant corrosion in the specimens immersed in uninhibited conditions. Potentiodynamic polarization test results showed an increase in corrosion potential (Ecorr) and decrease in corrosion current (icorr) value with increasing concentration of inhibitor. Conclusions: Immersion of steel in higher concentration of inhibitor resulted in greater surface coverage value and hence lesser number of surface corrosion sites/pores were formed; thus lowering the corrosion rate.

양극 산화 임플란트 표면 구조에 대한 염산 테트라싸이클린의 영향 (Micromorphometric Influence of Anodic oxidation surface implant conditioned with tetracycline-HCI)

  • 임정택;정종혁;권영혁;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.767-777
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Anodic oxidation surface were utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for ${\frac{1}{2}}min.$, 1min., $1{\frac{1}{2}}min.$, 2min., $2{\frac{1}{2}}min.$, and 3min. respectively in the test group. Then, specimens were processed for Ra Value test and scanning electron microscopic observation. The results of this study were as follows. 1. The anodic oxidation surface roughness tests don't show significant difference on conditioning with saline and Tetracycline-HCI. 2. The anodic oxidized surfaces showed the craterous structures. The surface conditioning with Tetracycline-HCI didn't influence on its micro-morphology. In conclusion, Anodic oxidation implant surface is stable to detoxificate with 50mg/ml Tetracycline-HCI of implant surface.

파주 금릉리 출토복식의 섬유외 성분 연구 -KS 시험규격의 활용을 중심으로- (Analysis of Nonfibrous Matters in the Textiles Exhumed from Keumreung-Ri, Pajoo Application of KS Test Method)

  • 안춘순;조한국
    • 한국의류학회지
    • /
    • 제22권6호
    • /
    • pp.772-780
    • /
    • 1998
  • The purpose of this research was to investigate the fiber content of and the characteristics of non-fibrous matters within the textiles exhumed from Keumreung-Ri, Pajoo of Kyunggi-do. Various microscopic methods' and the IR spectroscopy were used for the identification of fibers. The KS K 0251 Test Method as well as the IR spectroscopy and the SEM were used for the analysis of econ-fibrous matters. Fiber identification showed that each of the Pajoo samples were composed either of silk, cotton, or ramie. The results of the analysis of non-fibrous matters were as follows. The amount of water-extracted compound exceeded that of chloroform-extracted compound in both Pajoo 2 and Pajoo 5 samples. In Pajoo 5 sample which have already been dry cleaned using the mixed solution of n-hexane and n-dacane, the amount of chloroform extracted compound was 0% of the total extracted matter. The enzyme and HCI disintegration steps further removed the soils those were nonsoluble in water or chloroform. The most extraction was achieved at the HCI extraction stage.

  • PDF

미소경도 측정에 의한 590DP강 Subsurface Zone 내 수소취성 평가 (Hydrogen Embrittlement Evaluation of Subsurface Zone in 590DP Steel by Micro-Vickers Hardness Measurement)

  • 최종운;박재우;강계명
    • 한국재료학회지
    • /
    • 제21권11호
    • /
    • pp.581-586
    • /
    • 2011
  • This study describes a hydrogen embrittlement evaluation of the subsurface zone in 590DP steel by micro-Vickers hardness measurement. The 590DP steel was designed to use in high-strength thin steel sheets as automotive materials. The test specimens were fabricated to 5 series varying the chemical composition through the process of casting and rolling. Electrochemical hydrogen charging was conducted on each specimen with varying current densities and charging times. The relationship between the embrittlement and hydrogen charging conditions was established by investigating the metallography. The micro-Vickers hardness was measured to evaluate the hydrogen embrittlement of the subsurface zone in addition to the microscopic investigation. The micro-Vickers hardness increased with the charging time at the surface. However, the changing ratio and maximum variation of hardness with depth were nearly the same value for each test specimen under the current density of 150 mA/$cm^2$ and charging time of 50 hours. Consequently, it appears that hydrogen embrittlement in 590DP steel can be evaluated by micro-Vickers hardness measurement.

분사압력 변이에 따른 70 N급 액체로켓엔진 인젝터의 분무성능특성 (Effects of Injection Pressure on the Spray Performance Characteristics of the 70 N-class Liquid-rocket Engine Injector)

  • 정훈;김종현;김정수;박정;이재원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.180-186
    • /
    • 2012
  • 본 연구팀에서 개발 중인 70 N급 액체로켓엔진의 설계성능 검증에 앞서 요소부품인 비충돌형 인젝터에 대한 인수시험 및 수류시험을 수행하였다. 인젝터 오리피스 인수시험 결과 미시적 관점에서의 가공오차가 확인되었으며, 그로 인해 각각의 오리피스에서 발현되는 분무거동에 차이를 보였다. 순간 분무이미지를 통해 액주(혹은 액적) 표면에 나타나는 파동과 유동의 주기적 흘림현상을 관찰하였다.

  • PDF

A new burn-up module for application in fuel performance calculations targeting the helium production rate in (U,Pu)O2 for fast reactors

  • Cechet, A.;Altieri, S.;Barani, T.;Cognini, L.;Lorenzi, S.;Magni, A.;Pizzocri, D.;Luzzi, L.
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1893-1908
    • /
    • 2021
  • In light of the importance of helium production in influencing the behaviour of fast reactor fuels, in this work we present a burn-up module with the objective to calculate the production of helium in both in-pile and out-of-pile conditions tracking the evolution of 23 alpha-decaying actinides. This burn-up module relies on average microscopic cross-section look-up tables generated via SERPENT high-fidelity calculations and involves the solution of the system of Bateman equations for the selected set of actinide nuclides. The results of the burn-up module are verified in terms of evolution of actinide and helium concentrations by comparing them with the high-fidelity ones from SERPENT, considering two representative test cases of (U,Pu)O2 fuel in fast reactor conditions. In addition, a code-to-code comparison is made with the independent state-of-the-art module TUBRNP (implemented in the TRANSURANUS fuel performance code) for the same test cases. The herein presented burn-up module is available in the SCIANTIX code, designed for coupling with fuel performance codes.

Experimental study on damage and debonding of the frozen soil-concrete interface under freeze-thaw cycles

  • Liyun Tang;Yang Du;Liujun Yang;Xin Wang;Long Jin;Miaomiao Bai
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.663-671
    • /
    • 2023
  • Freeze-thaw cycles induce strength loss at the frozen soil-concrete interface and deterioration of bonding, which causes construction engineering problems. To clarify the deterioration characteristics of the interface under the freeze-thaw cycle, a frozen soil-concrete sample was used as the research object, an interface scanning electron microscope test under the freeze-thaw cycle was carried out to identify the micro index information, and an interface shear test was carried out to explore the loss law of interface shear strength under the freeze-thaw cycle. The results showed that the integrity of the interface was destroyed, and the pore number and pore size of the interface increased significantly with the number of freeze-thaw cycles. The connection form gradually deteriorates from surface-to-surface contact to point-to-surface contact and point-to-point contact, and the interfacial shear strength decreases the most at 0-3 freeze-thaw cycles, with small decreases from to 3-8 cycles. After 12 freeze-thaw cycles, the interfacial shear strength tends to be stable, and shear the failure occurs internally in the soil.

광섬유 FBG센서를 이용한 원주형 구조물의 2차원 상대변위 모니터링기법 개발 (Development of a Convergence Monitoring Method for Cylindrical Structures by Optical Fiber Bragg Grating Sensor)

  • 노병철;김종우;강석화
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.160-166
    • /
    • 2006
  • 본 연구에서는 광섬유 FBG 센서를 이용, 곡률반경을 고려한 이 방향 변위(Two-Way Displacement)를 측정하여 변형각을 환산함으로써 상대좌표를 구하는 알고리즘을 정립하였으며 이를 이용하면 작은 변형에 대해서도 매우정확하게 상대변위를 구할 수 있음을 알 수 있었다. 이를 확인하기 위해 4.5m높이의 H형강에 고안된 이 방향 광섬유센서를 부착하여 횡 방향으로 외력을 가해서 발생한 변위를 수준측량과 일반적인 전자식 변위계로 동시에 측정하여 각각의 측정성능을 비교분석하였다. 그 결과, 광섬유센서의 분해능은 다른 센서시스템에 비해 월등하였으며 이차원 상대좌표의 측정이 가능함을 확인하였다.