• Title/Summary/Keyword: Micropile angle

Search Result 15, Processing Time 0.026 seconds

Bearing Characteristics of Micropile-raft by Failure Mode of Soil (지반파괴거동에 따른 마이크로파일-기초의 지지특성)

  • Hwang, Tae-Hyun;Shin, Jong-Ho;Huh, In-Goo;Kwon, Oh-Yeob
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.13-25
    • /
    • 2015
  • With the increasing usages of micropile, several researchers have been studying the bearing characteristics of micropile or micropile-raft system. But most cases of research were focused on the bearing capacity of micropile-raft system on sand layer. And it was not considered that the bearing capacity of micropile-raft system was affected by the failure mode of soil and pile installation conditions. Thereby this study conducted the numerical analysis to estimate the bearing capacity of micropile-raft system on sand or silt layer with different shear failure mode. It was found that the bearing capacity of micropile-raft system installed in positive or negative angle was larger than that of the system installed in vertical angle, in the case of the sand layer undergoing the general shear failure. In the case of silt layer undergoing the punching shear failure, the bearing capacity of micropile-raft system installed only in negative angle was larger than that installed in vertical or positive angle. And the bearing capacity of foundation system in positive angle was similar to the vertical micropile-raft system.

Variations of Lateral Bearing Capacity of 2-row Micropile with Installation Conditions by Model Test (모형시험을 통한 복열 마이크로파일의 설치조건에 따른 수평 지지력 변화)

  • Hwang, Tae-Hyun;Kim, Mu-Yeun;Lee, Yeong-Saeng
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.35-49
    • /
    • 2020
  • The lateral bearing capacity of the micropile depends on the installed conditions such as number, installation angle and spacing of the pile. Existing research on micropile has been limited to the evaluation of vertical bearing characteristics and suggestion of effective installation methods, and there are few studies on failure mechanisms such as failure mode. And most of the studies on the lateral bearing capacity of micropile are also on the 1-row micropile. Therefore, in this study, a model test was performed to evaluate the behavior and lateral bearing characteristics of a 2-row micropile when the installed conditions such as the installation length, angle, and spacing of the pile were different. As a result of the model test, when the installation angle is θ > 0° (Not cross installation), the lateral bearing capacity of 2-row micropile depends on the spacing of the piles, and the installation angle θ = +30° was the most effective for increasing the bearing capacity. In addition, when the installation angle is θ < 0° (Overlap installation), it depends on the spacing and angle of the pile, and the condition of installation angle θ = -15° was found to be the most effective for increasing the bearing capacity.

Horizontal Bearing Characteristics of Micropiles with the Length Ratio and Installation Angle of Pile (파일길이비와 파일설치각도에 따른 마이크로파일 수평지지특성)

  • Oh, Joung-Bae;Hwang, Tae-Hyun;Huh, In-Goo;Shin, Jong-Ho;Kwon, Oh-Yeob
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.6
    • /
    • pp.5-13
    • /
    • 2015
  • Micropile was mainly used as one of underpinnig methods, and recently has been used for the various purposes such as foundation for new structure or slope stability etc. However, despite of the increase of the usage of micropile, studies about the horizontal bearing characteristic of micropile are insufficient. Thus the model test has been conducted to investigate the horizontal bearing characteristics of micropile with the length ratio and installation angle of pile. Consequently, micropiles at the installation angle of $+30^{\circ}$ and $-30^{\circ}$ effectively increase the horizontal bearing capacity, respectively for L/d ${\leq}25$ and L/d > 50.

Numerical Assessment of Load Sharing Behavior on Capped Micropile Foundation Systems (캡으로 연결된 마이크로파일 기초시스템의 하중분담거동에 관한 수치해석 평가)

  • Jung, Dong-Jin;Park, Seong-Wan;Cho, Kook-Hwan;Sim, Young-Jong
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.17-26
    • /
    • 2009
  • The concrete cap, which was established on the top of the micropile, usually considered as an important structural component in micropile supported foundation systems. However, relatively few studies have been made on the load sharing behavior of the capped micropile foundation systems. The primary objective of this study is to assess the load sharing behavior of the capped micropile foundation systems. Therefore, a full-scale test on an instrumented capped micropile is conducted for establishing the load-displacement responses. Nonlinear numerical method was used to quantify the load sharing behavior of the pile cap and micropile respectively. As a result, it was found that the pile cap shares about 50% load from final loading steps in the case of 2 by 1 micropile foundation systems. In the case of 2 by 2, the pile cap shares about 30% load from final loading steps. In addition, the load sharing behavior of the micropile cap becomes larger with an increase in spacing and the battered angle of micropile respectively.

Numerical Evaluation of Behavior on Bridge Foundation Reinforced by Battered Micropiles (경사진 마이크로파일로 보강된 교량기초의 거동에 관한 수치 해석적 연구)

  • Jung, Dong-Jin;Park, Seong-Wan;Kwak, Ki-Seok;Lee, Ju-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.514-519
    • /
    • 2006
  • The purpose of this study is to evaluate the performance of existing bridge foundation reinforced by battered micropiles. In order to do numerical method using a Finite element program was used to predict the micropile behavior and quantify their reinforcing effect to existing bridge foundations. In addition, effect of battered micropiles on existing foundations was compared with vertically reinforced bridge foundations. Based on the study performed, it was found that the use of battered micropile is more efficiently reducing displacement of existing foundation than vertically installed micropiles under vertical and horizontal loadings respectively. The batter angle of micropile was also found effective about $15^{\circ}\sim20^{\circ}$ to reduce the vortical displacement. The horizontal reinforcement effect is continuously larger with an increase in batter angle. So, it is believed that the results presented could give an idea to enhance in-service performance of existing bridge foundations reinforced by micropiles.

  • PDF

Uplift Behavior of Group Micropile according to Embedded Pile Condition in Sand (사질토지반에서 그룹 마이크로파일의 설치조건에 따른 인발거동특성)

  • Kyung, Doo-Hyun;Kim, Ga-Ram;Park, Dae-Sung;Kim, Dae-Hong;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.27-37
    • /
    • 2015
  • The micropile is small diameter pile foundation of which diameter is below 300 mm. This system has been applied to reinforce the foundation structure. In the present study, the effects of embedded conditions of group micropiles were investigated from a series of uplift load tests. For the study, uplift load tests were performed using group micropiles in various pile spacing and installation angle. The increase of uplift resistance and the reduction of uplift displacement were investigated in the tests. As the result, the resistances were principally changed by embedded pile angle, the resistance increase were 33%, 59% and 5% for $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of embedded pile angle. The uplift displacement reduction increases with lower pile spacing condition and the reduction ratios of uplift displacements in the same spacing condition were 50%, 53%, -45% for $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of embedded pile angle.

Compressive Behavior of Micropile According to Pile Spacing and Embedded Pile Angle in Sand (사질토 지반에 설치된 마이크로파일의 설치간격 및 설치각도에 따른 압축거동특성)

  • Kyung, Doo-Hyun;Kim, Ga-Ram;Kim, Dae-Hong;Shin, Ju-Ho;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.57-67
    • /
    • 2013
  • Micropile technology has evolved continuously since its instruction by Fernando Lizzi in the 1950s. The effects of group micropile have been researched by many researchers. The effects of group micropile differ and change with pile length, pile spacing (S), pile angle (${\theta}$) and pile embedded conditions. In the present study, the effects of resistance increase and settlement reduction from micropiles were investigated through a series of axial load tests. For the study, axial load tests were performed using mat, group micropiles and micropiled-raft (MPR) in various pile spacing and pile angle conditions. As the result, the effects of resistance of micropiled-raft were 80% (3D) to 110% (7D) of the total resistance of mat and group micropile. The effects of settlement restraint of micropiled-raft were 20% (S=3D, ${\theta}=45^{\circ}$) to 70% (7D, ${\theta}=15^{\circ}$) of settlement of mat foundation.

An Experimental Study on the Increase of the Bearing Capacity on Sandy Ground due to Micropile Reinforcement (마이크로파일로 보강된 모래지반의 지지력 증가효과에 관한 실험적 연구)

  • 김정동;임종철;이태형
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.411-416
    • /
    • 2003
  • As rapid industrialization continues in these days, construction in the down town areas increases. Since constructions are performed around old and existing structures, the need to provide reinforcements to protect the existing structures from collapse and damage arises. Furthermore, if the construction is to take place in the down town area, difficult work space and damage caused by noise, vibration and collapse of structure can't be ignored. Among the remedial measures available today, micropile reinforcement is considered the best method to remedy these problems. But up to the present the characteristics of micropiles and ground behaviour has not been proven and no standard design is not yet available. Therefore, most design are performed based on previous experiences. In this study, the difference in the bearing capacity with changing reinforcement angle, space and sphere around foundation was monitored. These results were induced to broaden heighten the limits of micropile application.

  • PDF

Evaluation of the Reinforcing Effect on Shallow Foundation by Micropiles (Micropile에 의한 얕은기초의 보강효과)

  • Jeang, Jae-Young;Bae, Kyung-Tae;Park, Seong-Wan;Lee, Chong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.538-543
    • /
    • 2004
  • Micropile has been widely used for reinforcing general grounds, improving slope stability and structural foundations. However, a need still exists for evaluating the effects of inclined micropiles on shallow foundations in Korea. In this paper, numerical analyses were presented to evaluate settlement characteristics on shallow foundations reinforced by micropiles and the effects of inclined micropiles under various conditions such as the installation position, installation angle, hardness(diameter), and grouting type. In addition, this paper reports trends of effectiveness and efficiency of using inclined micropiles on shallow foundations under specified conditions.

  • PDF

Dynamic Behavior of Triaxial Micropile Under Varying Installation Angle: A Numerical Analysis (수치해석을 통한 설치 경사각도에 따른 삼축내진말뚝의 동적 거동특성)

  • Jeon, Jun-Seo;Meron Alebachew Mekonnen;Kim, Yoon-Ah ;Kim, Jong-Kwan;Yoo, Byeong-Soo ;Kwon, Tae-Hyuk;An, Sung-Yul ;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.11
    • /
    • pp.41-51
    • /
    • 2023
  • This study employs three-dimensional simulation through FLAC3D to investigate the impact of installation angles on the dynamic characteristics of Triaxial Micropiles. The numerical model is validated against centrifuge test results to ensure accuracy. The findings reveal significant influences of the installation angle on the dynamic behavior of Triaxial Micropiles. Specifically, under seismic conditions such as the Capetown and San Fernando earthquakes, the lowest recorded values for peak bending moment and settlement occurred at an installation angle of 15 degrees. In contrast, when subjected to an artificial earthquake with a frequency of 2 Hz (Sine 2 Hz), Micropiles installed at 0 degrees exhibited the lowest peak bending moment, maximum axial load, and settlement values.