• 제목/요약/키워드: Microfluidic chip

검색결과 152건 처리시간 0.032초

Microfluidic Biosensor System for HDL Cholesterol

  • Kim, Joo-Eun;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.717-720
    • /
    • 2003
  • A chromogenic biosensor employing microfluidics on a chip has been developed for the determination of high-density lipoprotein (HDL) cholesterol (HDL-C) in human serum. We have investigated a plain and effective method to immobilize enzymes within the microchip without chemically modifying micro-channel or technically micro-fabricating column reactor and fluid channel network. In assessing risk factors of coronary heart disease, a micro-chip system would minimize requirements of instrument and reagent handling.

  • PDF

Magnetic Sensor-Based Detection of Picoliter Volumes of Magnetic Nanoparticle Droplets in a Microfluidic Chip

  • Jeong, Ilgyo;Eu, Young-Jae;Kim, Kun Woo;Hu, XingHao;Sinha, Brajalal;Kim, CheolGi
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.302-307
    • /
    • 2012
  • We have designed, fabricated and tested an integrated microfluidic chip with a Planar Hall Effect (PHE) sensor. The sensor was constructed by sequentially sputtering Ta/NiFe/Cu/NiFe/IrMn/Ta onto glass. The microfluidic channel was fabricated with poly(dimethylsiloxane) (PDMS) using soft lithography. Magnetic nanoparticles suspended in hexadecane were used as ferrofluid, of which the saturation magnetisation was 3.4 emu/cc. Droplets of ferrofluid were generated in a T-junction of a microfluidic channel after hydrophilic modification of the PDMS. The size and interval of the droplets were regulated by pressure on the ferrofluid channel inlet. The PHE sensor detected the flowing droplets of ferrofluid, as expected from simulation results. The shape of the signal was dependent on both the distance of the magnetic droplet from the sensor and the droplet length. The sensor was able to detect a magnetic moment of $2{\times}10^{-10}$ emu at a distance of 10 ${\mu}m$. This study provides an enhanced understanding of the magnetic parameters of ferrofluid in a microfluidic channel using a PHE sensor and will be used for a sample inlet module inside of integrated magnetic lab-on-a-chip systems for the analysis of biomolecules.

혼합 기능을 갖는 마이크로 펌프의 연구 (A Study on the MHD Micropump with Mixing Function)

  • 최범규;강호진;김민석
    • 대한기계학회논문집B
    • /
    • 제34권6호
    • /
    • pp.579-586
    • /
    • 2010
  • MEMS 기술의 향상과 함께 $\mu$-TAS(Micro Total Analysis System)가 개발 되어 의료 및 생물학 분야가 급속하게 성장했다. $\mu$-TAS의 한 분야로 Chip 위에서 소량의 sample과 반응물을 가지고 혼합공정과 분석공정이 이루어지는 LOC(Lab on a chip)에 관한 연구는 활발하게 연구되어진다. LOC는 마이크로 펌프 와 마이크로 믹서와 같은 microfluidic 장치들로 구성된다. Microfluidic 시스템의 유동이 층류 유동이므로 유체상태의 반응물들을 효율적으로 혼합하고 공급하는 것이 어렵다. 본 논문은 이송 및 혼합이 동시에 이루어지는 MHD micropump의 설계와 제작에 관해 제시하였다. 최종 개선사양은 상용 CFD 프로그램의 해석결과를 통하여 결정하였다.

동심축류가 유도되는 미세유체 소자 기반 Collagen Type I 미세섬유의 제작 (Fabrication of Collagen Type I Microfiber based on Co-axial Flow-induced Microfluidic Chip)

  • 이수경;이광호
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.186-194
    • /
    • 2016
  • In this study, a co-axial flow induced microfluidic chip to fabricate pure collagen type I microfiber via the control of collagen type I and Na-alginate gelation process. The pure collagen type I microfiber was generated by selective degradation of Ca-alginate from 'Core-Shell' structured hydrogel microfiber. To make 'Core-Shell' structure, collagen type I solution was introduced into core channel and 1.5% Na-alginate solution was injected into side channel in microfluidic chip. To evaluatethe 'Core-Shell' structure, the red and green fluorescence substances were mixed into collagen type I and Na-alginate solution, respectively. The fluorescence substances were uniformly loaded into each fiber, and the different fluorescence images were dependent on their location. By immoblizing EpH4-Ras and C6 cells within collagen type I and Na-alginate solution, we sucessfully demonstrated the co-culture of EpH4-Ras and C6 cells with 'Core-Shell' like hydrogel microfiber for 5 days. Only to produce pure collagen type I hydrogel fiber, tri-sodium citrate solution was used to dissolve the shell-like Ca-alginate hydrogel fiber from 'Core-Shell' structured hydrogel microfiber, which is an excellent advantage when the fiber is employed in three-dimensional scaffold. This novel method could apply various application in tissue engineering and biomedical engineering.

마이크로 유동 네트워크 설계를 위한 1차원 GUI 프로그램 개발에 관한 연구 (A STUDY ON THE DEVELOPMENT OF ONE-DIMENSIONAL GUI PROGRAM FOR MICROFLUIDIC-NETWORK DESIGN)

  • 박인형;강상모;서용권
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.86-92
    • /
    • 2009
  • Nowadays, the development of microfluidic chip [i.e. biochip, micro-total analysis system ($\mu$-TAS) and LOC (lab-on-a-chip)] becomes more active, and the microchannels to deliver fluid by pressure or electroosmotic forces tend to be more complex like electronic circuits or networks. For a simple network of channels, we may calculate the pressure and the flow rate easily by using suitable formula. However, for complex network it is not handy to obtain such information with that simple way. For this reason, Graphic User Interface (GUI) program which can rapidly give required information should be necessary for microchip designers. In this paper, we present a GUI program developed in our laboratory and the simple theoretical formula used in the program. We applied our program to simple case and could get results compared well with other numerical results. Further, we applied our program to several complex cases and obtained reasonable results.

폴리다이아세틸렌을 이용한 미세유동칩 내의 온도 측정 (Temperature Measurements in a Microfluidic Chip with Polydiacetylene Sensor)

  • 장영식;류성민;송시몬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2696-2699
    • /
    • 2008
  • Microfluidic chips have been frequently utilized to perform biochemical analysis, like cell culture, because they reduce the consumptions of analytes and reagents and automate multi-step analysis processes. It is often critical to monitor temperature in a microchannel for the analyses in order to control a reaction condition of bio or chemical molecules. We propose a novel method to monitor temperature of a microchannel flow by using polydiacetylene (PDA), a conjugated polymer, that has a unique property to transform its color from visible blue to fluorescent red by thermal stress. We inject PDA sensor droplets generated by hydrodynamic instability into a microchannel with a microheater incorporated on the channel bottom. Also, we change the channel temperature by providing the different electric power to the microheater. The results show that the florescence intensity of PDA sensor droplets linearly increases in response to the flow temperature increase within a certain range.

  • PDF

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

전기 검출 시스템을 이용한 Microfluidic Immuno-Sensor Chip (Microfluidic Immuno-Sensor Chip using Electrical Detection System)

  • 맹준호;이병철;조철호;고용준;안유민;조남규;이성환;황승용
    • KSBB Journal
    • /
    • 제21권5호
    • /
    • pp.325-330
    • /
    • 2006
  • Bio-MEMS를 기반으로 microfilter와 백금 전극이 내재되어 있는 microbiochip을 제작하였다. 우리는 이 chip으로 microbead에 indirect ELISA 방법으로 항원-항체를 반응시키고 전기 신호 검출 방법을 이용하여 반응 여부를 판단하였다. 이 때 신호 증폭을 위해 silver enhancer를 사용하였다. Chip 상에서 항원-항체 반응 조건을 최적화하기 위해 pH, temperature, flow time, flow rate, silver enhancer time을 결정하였다. 이렇게 최적화된 조건을 바탕으로 짧은 시간 안에 소량의 시료로 immunoassay를 성공적으로 수행할 수 있었다. 전기 신호 검출 방식을 사용함으로써 biosensor 장비의 소형화와 다중 시료 측정과 자동화를 biosensor에서 적용할 수 있는 가능성을 제시하였다.