• Title/Summary/Keyword: Microelectrode

Search Result 142, Processing Time 0.03 seconds

SNP Detection Using Indicator-free DNA Chip (비수식화 DNA를 이용한 유전자 검출)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.410-411
    • /
    • 2006
  • High throughput analysis using a DNA chip microarray is powerful tool in the post genome era. Less labor-intensive and lower cost-performance is required. Thus, this paper aims to develop the multi-channel type label-free DNA chip and detect SNP (Single nucleotide polymorphisms). At first, we fabricated a high integrated type DNA chip array by lithography technology. Various probe DNAs were immobilized on the microelectrode array. We succeeded to discriminate of DNA hybridization between target DNA and mismatched DNA on microarray after immobilization of a various probe DNA and hybridization of label-free target DNA on. the electrodes simultaneously. This method is based on redox of an electrochemical ligand.

  • PDF

An efficient method applied to spike pattern detection

  • Duc, Thang Nguyen;Kim, Tae-Seong;Lee, Young-Koo;Lee, Sung-Young
    • Annual Conference of KIPS
    • /
    • 2007.05a
    • /
    • pp.558-559
    • /
    • 2007
  • The detection of neural spike activity is a technical challenge that is very important for studying many types of brain function. On temporal recordings of firing events or interspike interval series of neural signal, spike pattern correspond to action will be repeated in the presence of background noise and they need to be detected to develop higher applications. We will introduce new method to find these patterns in raw multitrial data and is tested on surrogate data sets with the main target to get meaningful analysis of electrophysiological data from microelectrode arrays (MEA).

STN DBS of Advanced Parkinson's Disease Experienced in a Specialized Monitoring Unit with a Prospective Protocol

  • Lee, Ji-Yeoun;Han, Jung-Ho;Kim, Han-Joon;Jeon, Beom-Seok;Kim, Dong-Gyu;Paek, Sun-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.26-35
    • /
    • 2008
  • Objective : In the evaluation of patients with Parkinson's disease (PD), most neurologists only see their patients during a limited period of their fluctuating 24-hour-a-day lives. This study aimed to assess the short-term outcome of STN stimulation for patients with advanced PD evaluated in a 24-hour monitoring unit for movement disorder (MUMD) using a prospective protocol. Methods : Forty-two patients with advanced PD consecutively treated with bilateral STN stimulation using multi-channel microelectrode recording were included in this study. All patients were evaluated using a 24-hour MUMD with a video recording/editing system and were evaluated with a prospective protocol of the Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Staging, Schwab and England Activities of Daily Living, levodopa equivalent daily dose (LEDD), Short Form-36 Health Survey, and neuropsychological tests. Magnetic resonance (MR) images of the brain were performed prior to and six months after surgery. Results : All patients were evaluated at three and six months after surgery. There was a rapid and significant improvement of the motor symptoms, especially in tremor and rigidity, after STN stimulation with low morbidity. Dyskinesia was markedly decreased with much lowered LEDD values by 50% after STN stimulation. 1.5T MR images were safely taken according to the manufacturer's guidelines at six months after surgery without any adverse effects in 41 patients treated with STN stimulations. Conclusion : Evaluations in a 24-hour monitoring unit could reduce the dose of medication efficiently to an optimal level with patients' comfort and improve the clinical symptoms in harmony with STN stimulation.

Electrochemical Hydrogenation Behavior of Surface-Treated Mg-based Alloys for Hydrogen Storage of Fuel Cell (연료전지의 수소저장용 마그네슘계 합금의 표면제어에 의한 전기화학적 수소화 거동 연구)

  • Kim, Ho-Sung;Lee, Jong-Ho;Boo, Seong-Jae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.46-52
    • /
    • 2006
  • The effects of surface treatment on the hydrogen storage properties of a $Mg_2Ni$ alloy particle were investigated by the microvoltammetric technique, in which a carbon-filament microelectrode was manipulated to make electrical contact with the particle in a KOH aqueous solution. It was found that the hydrogen storage properties of $Mg_2Ni$ at room temperature were improved by the surface treatment with a nickel plating solution. The sodium salts(sodium phosphate and sodium dihydrogen citrate) contained in the nickel plating solution made the alloy form an amorphous-like state, resulting in an improved hydrogen charge/discharge capacity at room temperature as high as about 150[mAh/g] from the original value of 17[mAh/g]. Potential-step experiment was carried out to determine the apparent chemical diffusion coefficient of hydrogen atom($D_{app}$) in the alloy. Since the alloy particle we used here was a dense, conductive sphere, the spherical diffusion model was employed for data analysis. $D_{app}$ was found to vary the order between $10^{-8}{\sim}10^{-9}[cm^2/s]$ over the course of hydrogenation and dehydrogenation process.

Genome Detection Using an Integrated type DNA Chip Microelectrode-array and Non-labeling Target DNA (집적형 DNA칩 미소 전극 어레이 및 비수식화 표적 DNA를 이용한 유전자 검출)

  • Choi, Yong-Sung;Lee, Hea-Yeon;Tanaka, Hiroyuki;Tanaka, Hidekafu;Kwon, Young-Soo;Kawai, Tomoii
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.274-276
    • /
    • 2001
  • This research aims to develop the multiple channel electrochemical DNA chip using microfabrication technology. At first, we fabricated a high integration type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the sold electrodes. Then target DNAs were hybridized and reacted. Cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. Therefore, it is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

Fabrication and Characterization of Multi-Channel Electrode Array (MEA) (다중 채널 전극의 제작 및 특성 평가)

  • Seong, Rak-Seon;Gwon, Gwang-Min;Park, Jeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.9
    • /
    • pp.423-430
    • /
    • 2002
  • The fabrication and experimentation of multi-channel electrodes which enable detecting and recording of multi-site neuronal signals have been investigated. A multi-channel electrode array was fabricated by depositing 2000${\AA}$ thick Au layer on the 1000${\AA}$ thick Ti adhesion layer on a glass wafer. The metal paths were patterned by wet etching and passivated by depositing a PECVD silicon nitride insulation layer to prevent signals from intermixing or cross-talking. After placing a thin slice of rat cerebellar granule cell in the culture ring located in central portion of the multi-channel electrode plate, a neuronal signal from an electrode which is in contact with the cerebellar granule cell has been detected. It was found that the electrode impedance ranges 200㏀∼1㏁ and the impedance is not changed by cleaning with nitric acid. Also, the impedance is inversely proportion to the exposed electrode area and the cross-talk is negligible when the electrode spacing is bigger than 600$\mu\textrm{m}$. The amplitude and frequency of the measured action potential were 38㎷ and 2㎑, which are typical values. From the experimental results, the fabricated multi-channel electrode array proved to be suitable for multi-site neuronal signal detection for the analysis of a complicated cell network.

Physiological effects of magnesium in the guinea pig hearts (기니픽 심장에서 magnesium의 생리학적 영향)

  • Chang, Sung-eun;Kim, Shang-jin;Kang, Hyung-sub;Kim, Jin-shang
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.311-317
    • /
    • 2001
  • In this work we have investigated the physiological effects of $MgCl_2$ in isolated atrium, papillary muscle, perfused heart and anesthesized guinea pig, The addition or infusion of $MgCl_2$ (0~20 mM or mg/kg) to perfused hearts and to anesthesized guinea pigs induced a marked and dose-dependent negative chronotropic effect. The sinoatrial node automaticity could also be reduced by $MgCl_2$. The addition of $MgCl_2$to isolated atria and to papillary muscles induced a marked and dose-dependent negative inotropic effect. The threshold voltage could be increased by $MgCl_2$in papillary muscle. Increasing $MgCl_2$ shortened the action potential duration (APD) in dose-dependent manner at 30% ($APD_{30}$) and 90% repolarization ($APD_{90}$) measured with conventional microelectrode technique in papillary muscle. In anesthesized guinea pig, the magnesium infusion resulted in a dose-dependent drop in blood pressure. These results suggested that magnesium is closely associated with cardiac physiological condition and exerts antiarrhythmic activities.

  • PDF

Block of hERG $K^+$ Channel by Classic Histamine $H_1$ Receptor Antagonist Chlorpheniramine

  • Hong, Hee-Kyung;Jo, Su-Hyun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.3
    • /
    • pp.215-220
    • /
    • 2009
  • Chlorpheniramine is a potent first-generation histamine $H_1$ receptor antagonist that can increase action potential duration and induce QT prolongation in several animal models. Since block of cardiac human ether-a-go-go-related gene (hERG) channels is one of leading causes of acquired long QT syndrome, we investigated the acute effects of chlorpheniramine on hERG channels to determine the electrophysiological basis for its proarrhythmic potential. We examined the effects of chlorpheniramine on the hERG channels expressed in Xenopus oocytes using two-microelectrode voltage-clamp techniques. Chlorpheniramine induced a concentration-dependent decrease of the current amplitude at the end of the voltage steps and hERG tail currents. The $IC_{50}$ of chlorpheniramine-dependent hERG block in Xenopus oocytes decreased progressively relative to the degree of depolarization. Chlorpheniramine affected the channels in the activated and inactivated states but not in the closed states. The S6 domain mutations Y652A and F656A partially attenuated (Y652A) or abolished (F656A) the hERG current block. These results suggest that the $H_1$ antihistamine, chlorpheniramine is a blocker of the hERG channels, providing a molecular mechanism for the drug-induced arrhythmogenic side effects.

The Excitatory Mechanism of Substance P in the Antral Circular Muscle of Guinea Pig Stomach

  • Jun, Jae-Yeoul;Kim, Sung-Joon;Choi, Youn-Baik;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.28 no.1
    • /
    • pp.51-59
    • /
    • 1994
  • This study was carried out to elucidate the excitatory mechanisms of Substance P in the antral circular muscle, using isometric contraction recording, conventional microelectrode method and whole-cell patch clamp technique. Substance P produced tonic and phasic contractions in a dose-dependent manner and depolarized membrane potential with increased amplitude of slow waves in muscle strips. Voltage-dependent $Ca^{2+}$ currents were increased by the application of Substance P from a holding potential of -60mV to 50mV in 10mV steps and this effect was blocked by the addition of an antagonist. Also Substance P increased transient and spontaneous oscillatory $K^+$ outward currents. The enhanced outward currents were abolished by apamin in dispersed single cells. These results suggest that the depolarization of membrane potential by Substance P activates voltage-dependent $Ca^{2+}$ channels, which represents an excitatory response in the antral circular muscle and led to an increase in $Ca^{2+}\;activated\;K^+\;currents$.

  • PDF

The Electrode Shape for the Efficient Separation of Cell in Dielectrophoresis-Activated Cell Sorter (유전영동을 이용한 입자분리기의 효율적인 분리를 위한 전극 형태)

  • An, Jae-Min;Chae, Seung-Yeub;Park, Seok-Ho;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • This paper presents the optimal shape of microelectrode that generates dielectrophoretic(DEP) force to separate particles in homogeneous medium. The principle of the particles sorting is based on the use of the relative strengths of negative DEP (nDEP) and drag forces, as in a general DEP-activated cell sorter (DACS). To numerically calculate the DEP force and drag force, the simulation is implemented in MATLAB 7.0. The properties of particles, which are used in simulation, are similarly selected as those of cells to apply cell separation. The most optimized shape of electrode is selected by numerical simulation according to a variety of electrode shape such as rectangle, trapezoidal, and right-triangle. Through, in addition, parameter study, we found that applied frequency is more significant factor on the separation than various parameters, such as applied voltage and permittivity of medium, that decide on the strength of DEP force.