• Title/Summary/Keyword: Microcurrent Stimulation

검색결과 38건 처리시간 0.025초

미세전류 손목 보호대 착용이 손목터널증후군 노인 여성의 통증 척도, 관절가동범위 및 근력에 미치는 영향 (Effects of Wearing a Microcurrent Wrist Guard on Pain Scale, Range of Motion, and Muscle Strength in Elderly Women with Carpal Tunnel Syndrome)

  • 박혜선;박진희;김주용
    • 패션비즈니스
    • /
    • 제27권5호
    • /
    • pp.1-12
    • /
    • 2023
  • The purpose of this study was to investigate impact of wearing low-level current wrist guards on pain scale, range of motion (ROM), and muscle strength in elderly women with Carpal Tunnel Syndrome (CTS). Subjects were 12 elderly women aged between 65 and 85 years who were diagnosed with CTS symptoms. Measurements included grip strength and wrist ROM. Wrist ROM was assessed through flexion and dorsiflexion. Wrist guards were worn. After two weeks, pain level was assessed using the Visual Analogue Scale (VAS). Results showed a significant reduction in VAS score in the MES group after stimulation, whereas there was no difference in the control group. However, there was no significant difference in ROM between the MES group and the control group. Grip strength increased in the MES group after two weeks (p ≤ 0.001). In conclusion, clinical trials suggest that MES wrist guards might be provided as an adjunctive treatment method for CTS patients. This study provides foundational data for the design and use of auxiliary devices such as gloves in the field of MES research for pain reduction, ROM improvement, and muscle strength enhancement resulting from CTS.

실험적 통증유발 모델에서 조기발현 유전자에 대한 미세전류자극의 효과 (The Effect of Microcurrent Stimulation on Immediately Early Gene in Pain Induced Model)

  • 김계엽;김태열;오명화;김선은;정미선;서영숙
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.9-21
    • /
    • 2004
  • The purpose of study is that we will observe the change of c-fos with the immunohistochemistry method and then we will study the effect of micro current stimulation following the frequency after inducing pain to rats with capsaicin. Rat were classified to SD and they have growed for 8 weeks. We classify to four groups, ordinal group is used in experiment I, the group which we induce pain is used in experiment II, the application group which we induce pain and then the high frequency micro current stimulation is used in experiment III, the application group which we induce pain and then the low frequency micro current stimulation is used in experiment IV, we get the following result. Compare with experiment II, experiment III, and experiment IV from acute pain modal in the immunohistochemistry experiment which has c-fos protein as an antigen, c-fos immunoreactive positive neurons significantly after induced pain for two hours(p<0.001). According to these results, from rats induced pain, micro current stimulation effect to reducing pain, but following frequency micro current stimulation theraphy isn't different from immunoreactive c-fos

  • PDF

좌골신경손상 쥐 모델을 이용한 미세전류 자극의 근위축 억제 효과 확인 및 자극 세기 별 비교 (The Effect of Microcurrent Electrical Stimulation on Muscle Atrophy Suppression in a Sciatic Nerve Injured Rat Model; Comparative Study by Current Intensity)

  • 황동현;김서현;이한아;장승준;김세빈;김택중;최수임;곽호영;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권4호
    • /
    • pp.175-182
    • /
    • 2017
  • Microcurrent electrical stimulation(MES) has been used to accelerate recovery of atrophied skeletal muscle. However, convincing stimulation parameters for suppressing muscle atrophy due to injured sciatic nerve remains unclear. The objective of this study was to investigate the effective intensity of MES on restraining muscle atrophy with rat model underwent sciatic nerve injury(SNI). Twenty-5-week-old Sprague Dawley male rats were equally assigned to five groups : Control group(Control, CON, n = 4), Denervation group(Denervation, D, n = 4), Denervation with MES of $22{\mu}A$ group(Denervation + $22{\mu}A$, D+22, n = 4), Denervation with MES of $100{\mu}A$ group (Denervation + $100{\mu}A$, D+100 n = 4), Denervation with MES of $400{\mu}A$ group(Denervation + $400{\mu}A$, D+400, n = 4). To induce muscle atrophy, all rats in the D, D+22, D+100, and D+400 groups, were subjected to sciatic nerve injury on their right hindlimb and allowed to have 1 week of resting period. Following this period, rats underwent daily MES(60 min/ a day, 5times/1week) for 4 weeks. After that, we investigate morphological changes in muscle volume by using in vivo micro-computed tomography at week 0, 1, 3 and 5. After 5 weeks, the muscle volume had the highest value in D+400 group, and also noticeably increased in D+100 group compared to it in D group. The results of this study imply that MES with current intensities between $100-400{\mu}A$ can suppress muscle atrophy effectively.

급성 외측 상과염 치료를 위한 휴대용 미세전류자극기 개발 및 효과 검증 (Development and Evaluation of a Portable Micro-Current Stimulator for Acute Lateral Epicondylitis)

  • 권혁찬;이현주;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.68-74
    • /
    • 2019
  • Lateral epicondylitis is caused by repeated use of the wrist, which causes inflammation and pain in the wrist extensor and tendon of the humerus. Delayed onset muscle soreness (DOMS) caused by repetitive resistance exercise affects the tendons connected in series with the muscle, leading to lateral epicondylitis. Although micro-current stimulation has been suggested as a possible treatment for tendinitis, there are insufficient studies on specific variables such as frequency. In this study, 15 healthy adult males and females developed DOMS in the wrist extensor and tendon in the humerus. The experimental group consisted of a low frequency group applying 20 Hz and a high frequency group applying 100 Hz according to the micro-current frequency. Each subject underwent an experiment for 5 days after DOMS, and the recovery rates were compared by measuring AROM, GPT, MST, PPT, and VAS. As a result, the 20 Hz group showed significant changes in AROM, MST, and VAS compared to the control group on the 4th day, and the recovery rate was also higher than that of the 100 Hz group. On the 5th day, recovery rate of 100 Hz group was higher than 20 Hz in AROM and PPT, and MST showed higher recovery rate than 20 Hz group, but there was no significant difference. These results indicate that microcurrent stimulation is effective for the treatment of delayed myalgia and tendon inflammation and that the 100 Hz group has faster recovery than the 20 Hz group.

전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향 (Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect)

  • 심재창;김영준;정현주;김옥수
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

지연성 근육통에 대한 미세전류자극치료가 통증과 CK에 미치는 영향 (Effects of Microcurrent Delayed Onset Muscle Soreness on Creatine Kinase)

  • 조남정;송승혁
    • 대한통합의학회지
    • /
    • 제2권3호
    • /
    • pp.31-37
    • /
    • 2014
  • Purpose : Delayed onset muscle soreness(DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to compare the effect of both trascutaneous electrical nerve stimulation(TENS) Micro current(MC) and only normal Therapy on Delyed Onset Muscle Soreness(DOMS). Method : The Methods ten untrained and male volunteer subjects were randomly assigned to one of two treatment groups: 1) a group that received TENS (60Hz) MC($60{\mu}A$, 3pps) a control group that received no MC treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24hours and 48hours. Subjects attended on two consecutive days for treatment and measurement of paining(visual analogue scale: VAS) and CK(Creatine kinase) on a daily basis. Measurements were taken after treatment. Results : 1) There were no significant differences between TENS and MENS by two-way repeated ANOVA. The Results that t-test for VAS revealed significant differences within TENS group. 3) The t-test for VAS, and Creatine Kinase of time revealed significant differences within MC group. Conclusion : These findings suggest that both TENS and MENS had effect on DOMS.

미세전류치료와 초음파치료가 슬관절전치환술 후 통증경감과 기능회복에 미치는 영향 (The Effects of Microcurrent Treatment and Ultrasound Treatment on the Pain Relief and Functional Recovery after Total Knee Replacement)

  • 조운수;김용남;김용성;황태연;진희경
    • The Journal of Korean Physical Therapy
    • /
    • 제24권2호
    • /
    • pp.118-126
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate pain relief and functional recovery after total knee replacement. Methods: The treatment was performed by dividing individuals into a control group ($n_1=5$), ultrasound treatment group ($n_2=5$), and micro-current treatment group ($n_3=5$). The control group applied the hot pack for 15 minutes, Transcutaneous Electrical Nerve Stimulation (TENS) for 15 minutes, and Continuous Passive Movement (CPM) for 40 minutes. The ultrasound therapy group applied the frequency of 1 MHz, intensity of 1.0 $W/cm^2$ for five minutes following the same treatment as the control group. The micro-current therapy group applied the intensity of 25 ${\mu}A$, and pulsation frequency 5 pps for 15 minutes following the same treatment as the control group. After treatment, Visual Analogue Scale (VAS), Korean Western Ontario and McMaster Universities Arthritis Index (K-WOMAC), Berg Balance Scale (BBS), Range of Movement (ROM) and wound length was measured. Results: VAS showed significant effect in the control group and micro-current therapy group during the treatment period. According to the treatment of K-WOMACK, BBS, ROM, and Healing wounds showed main effects between groups. Conclusion: According to the results of this study, data showed improvement of pain relief, wound healing effects, and range of motion recovery. Thus, these selected treatments were effective after total knee replacement. In other words, electrical treatment continues to influence pain relief and functional recovery after total knee replacement.

마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발 (Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle)

  • 김준태;주규태;차은종;김명미;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.394-402
    • /
    • 2021
  • 고령사회의 진입과 인간의 평균 수명이 연장되고, 여성의 사회적 진출 및 남성들의 외모에 대한 관심증가, 미디어 매체를 통한 K-문화가 전 세계적으로 관심을 받으면서 자연스럽게 관심은 K-Bueaty에 집중되고 있다. 최근, 의료관광 분야의 점유를 보면 성형 및 피부과와 같은 피부미용 의료관광의 경우 중국, 일본 등 아시아뿐만 아니라 북미, 유럽 등에서 인기를 누리고 있다. 사람의 노화를 가장 먼저 외면적으로 확인할 수 있는 부위는 바로 얼굴의 피부 주름이다. 깨끗하고 주름이 없으면서 탄력성 있는 건강한 피부는 대부분의 사람들이 원하는 바람이다. 대표적으로 집속형초음파자극(HIFU:High Intensity Focused Ultrasound)와 저주파, 고주파(RF:Radio Frequency), 미세전류를 이용한 갈바닉 테라피, 급속 냉각을 이용한 크라이오 테라피 등 피부의 컨디션과 상태에 따라 관리하는 방식이 달라지며, 같은 기전을 이용한 의료기기 및 피부미용 기기의 시술 역시 출력 및 자극 부위 등에 따라 시술의 효과가 차이가 난다. 본 연구는 수많은 피부미용 의료기기 및 미용기기 중 마이크로니들을 이용한 침습형 고주파 피부 의료기기를 개발하고자 국제규격인 IEC 60601-2(의료기기개별기준규격)및 MFDS(Ministry of Food and Drug Safety : 식품의약품안전처)에서 고시한 고주파 자극기 기준 규격을 준수한 고주파 출력 장치를 설계 및 개발하였다. 회로 설계는 Class-A Topology를 이용한 증폭장치(AMP:Amplifier)와 Half-Bridge Topology를 이용한 전원장치로 이루어져 있다. 개발된 고주파 출력 장치를 측정한 결과 평균 63.86%의 효율을 얻었으며, 최대출력은 116.7W, 50.67dBm으로 측정되었다.