• Title/Summary/Keyword: Microclimate element

Search Result 4, Processing Time 0.025 seconds

자연에너지와 건축조경계획

  • Jo, Gyun-Hyeong
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.22-29
    • /
    • 1993
  • Indoor thermal environment and energy consumption of buildings are preferentially affected by the microclimate around buildings. It is the first method to improve energy conservation effect of buildings and the ways to utilize natural energy for the comfortable residential environment that the difference between the microclimate condition and the indoor thermal condition is made in minimum as far as possible. There are many factors to control and minimize the difference, but landscape element is the major one among the factors. In this respect, the report analyzes landscape elements and their function to control microclimate and presents basic data for the desirable landscape planning mehtods to improve energy conservation effect of buildings and to attain the comfortable residential environment.

  • PDF

Analysis of the effect of street green structure on PM2.5 in the walk space - Using microclimate simulation - (가로녹지 유형이 보행공간의 초미세먼지에 미치는 영향 분석 - 미기후 시뮬레이션을 활용하여 -)

  • Kim, Shin-Woo;Lee, Dong-Kun;Bae, Chae-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.4
    • /
    • pp.61-75
    • /
    • 2021
  • Roadside greenery in the city is not only a means of reducing fine dust, but also an indispensable element of the city in various aspects such as improvement of urban thermal environment, noise reduction, ecosystem connectivity, and aesthetics. However, in studies dealing with the effect of reducing fine dust through trees in existing urban spaces, microscopic aspects such as the adsorption effect of plants were dealt with, structural changes such as the width of urban buildings and streets, and the presence or absence of trees, Impact studies that reflect the actual form of In this study, the effect of greenery composition applicable to urban space on PM2.5 was simulated through the microclimate epidemiologic model ENVI-met, and field measurements were performed in parallel to verify the results. In addition, by analyzing the results of fine dust background concentration, wind speed, and leaf area index, the sensitivity to major influencing variables was tested. As a result of the study, it was confirmed that the fine dust reduction effect was the highest in the case with a high planting amount, and the reduction effect was the greatest at a low background concentration. Based on this, the cost of planting street green areas and the effect of reducing PM2.5 were compared. The results of this study can contribute as a basis for considering the effect of pedestrian space on air quality when planning and designing street green spaces.

Calculated external pressure coefficients on livestock buildings and comparison with Eurocode 1

  • Kateris, D.L.;Fragos, V.P.;Kotsopoulos, T.A.;Martzopoulou, A.G.;Moshou, D.
    • Wind and Structures
    • /
    • v.15 no.6
    • /
    • pp.481-494
    • /
    • 2012
  • The greenhouse type metal structures are increasingly used in modern construction of livestock farms because they are less laborious to construct and they provide a more favorable microclimate for the growth of animals compared to conventional livestock structures. A key stress factor for metal structures is the wind. The external pressure coefficient ($c_{pe}$) is used for the calculation of the wind effect on the structures. A high pressure coefficient value leads to an increase of the construction weight and subsequently to an increase in the construction cost. The EC1 in conjunction with EN 13031-1:2001, which is specialized for greenhouses, gives values for this coefficient. This value must satisfy two requirements: the safety of the structure and a reduced construction cost. In this paper, the Navier - Stokes and continuity equations are solved numerically with the finite element method (Galerkin Method) in order to simulate the two dimensional, incompressible, viscous air flow over the vaulted roofs of single span and twin-span with eaves livestock greenhouses' structures, with a height of 4.5 meters and with length of span of 9.6 and 14 m. The simulation was carried out in a wind tunnel. The numerical results of pressure coefficients, as well as, the distribution of them are presented and compared with data from Eurocodes for wind actions (EC1, EN 13031-1:2001). The results of the numerical experiment were close to the values given by the Eurocodes mainly on the leeward area of the roof while on the windward area a further segmentation is suggested.

Changes in Temperature and Humidity in the Forest Caused by Development (도로에 의한 산림 내 온습도 변화)

  • Choi, Jaeyong;Park, Myung-Soo;Kim, Su-Kyung;Yu, Seung-Hyeon;Choi, Won-Tae;Song, Wonkyong;Kim, Whee-Moon;Kim, Seoung-Yeal;Lee, Ji-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.604-617
    • /
    • 2018
  • As the depletion of forests became more widespread due to the increase in the number of roads, the research was conducted on the relationship between temperature and humidity in the forests, assuming that the forests around the roads were affected. Through the forest monitoring, the temperature and humidity of coniferous forests and broadleaf forests in Sedong and Gongju areas were observed at three point of 10m, 20m and 30m from the road boundary to the inside of the forest, respectively. In Yeongdong area, for more reliable results, it was observed from the point of 0m, 10m, and 20m. During the study period, so it was expected the change in tree growth was small, the change of temperature and humidity inside the forest by the road was compared with the temperature and humidity from the road to the inside of the forest from September 2017 to January 2018, the changes of temperature and humidity inside the forest due to linear development such as roads were quantitatively analyzed. Using the HOBO data logger (MX2301, Onset Corp.), the temperature and humidity changes of each site were measured, and the average of the changes have been analyzed monthly. In the case of Gongju coniferous forests in September 2017, the average weekly temperature is $0.57^{\circ}C$ higher than the forest outside from the forest boundary and $1.23^{\circ}C$ higher than the inside of the forest, at night in November 2017, in Sedong broadleaf forests. That is, the ability to control the temperature and humidity of the forests along the road was larger and less variable as the distance from the road boundary to the inside of the forest increased. In this study, it is considered that the high degree of change in temperature and humidity of the forest and the surrounding area due to artificial linear development such as roads will affect the growth of trees. This results could serve as a basis for studying the quantitative scope of linear development affecting forest growth and for managing forest change caused by linear development.