• Title/Summary/Keyword: Microclimate characteristics

Search Result 47, Processing Time 0.02 seconds

Guidelines for Tall Buildings Development

  • Al-Kodmany, Kheir
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.4
    • /
    • pp.255-269
    • /
    • 2012
  • Tall buildings' implementation has often lacked urban design and architectural guidance. There are many examples of tall buildings that have been inappropriately located, designed, and built, and consequently dissatisfaction with high-rise development is wide-spread. This paper attempts to provide extensive urban and architectural guidelines in order to manage cityscape and to ensure safe and healthy living. Through recommendations on design and layout of tall buildings and open spaces the guidelines seek enhancing the visual experience, improving the microclimate conditions, and fostering active social life. These guidelines help in providing enjoyable urban experiences through the examination of spatial relationships, human scale, genius loci, perceptual characteristics, local identity, built heritage, economic activities, and social life.

Simulation of Dynamic Characteristics of a Trigenerative Climate Control System Based On Peltier Thermoelectric Modules

  • Vasilyev, G.S.;Kuzichkin, O.R.;Surzhik, D.I.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.252-257
    • /
    • 2021
  • The application of the principle of trigeneration allows to simultaneously provide electricity to power electronic devices, as well as heat and cold to create the necessary microclimate of the premises and increase efficiency compared to separate cooling and heating systems. The use of Peltier thermoelectric modules (TEM) as part of trigenerative systems allows for smooth and precise control of the temperature regime, high manufacturability and reliability due to the absence of moving parts, resistance to shock and vibration, and small weight and size parameters of the system. One of the promising areas of improvement of trigenerative systems is their modeling and optimization based on the automatic control theory. A block diagram and functional model of an energy-saving trigenerative climate control system based on Peltier modules are developed, and the transfer functions of an open and closed system are obtained. The simulation of the transient characteristics of the system with varying parameters of the components is performed. The directions for improving the quality of transients in the climate control system are determined, as well as the prospects of the proposed methodology for modeling and analyzing control systems operating in substantially nonlinear modes.

Validation of ENVI-met Model with In Situ Measurements Considering Spatial Characteristics of Land Use Types (토지이용 유형별 공간특성을 고려한 ENVI-met 모델의 현장측정자료 기반의 검증)

  • Song, Bong-Geun;Park, Kyung-Hun;Jung, Sung-Gwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.2
    • /
    • pp.156-172
    • /
    • 2014
  • This research measures and compares on-site net radiation energy, air temperature, wind speed, and surface temperature considering various spatial characteristics with a focus on land use types in urban areas in Changwon, Southern Gyeongsangnam-do, to analyze the accuracy of an ENVI-met model, which is an analysis program of microclimate. The on-site measurement was performed for three days in a mobile measurement: two days during the daytime and one day during the nighttime. The analysis using the ENVI-met model was also performed in the same time zone as the on-site measurement. The results indicated that the ENVI-met model showed higher net radiation than the on-site measurement by approximately $300Wm^{-2}$ during the daytime whereas the latter showed higher net radiation energy by approximately $200Wm^{-2}$ during the nighttime. The temperature was found to be much higher by approximately $2-6^{\circ}C$ in the on-site measurement during both the daytime and nighttime. The on-site measurement also showed higher surface temperature than the ENVI-met by approximately $7-13^{\circ}C$. In terms of the wind speed, there was a significant difference between the results of the ENVI-met model and on-site measurement. As for the correlation between the results of the ENVI-met model and on-site measurement, the temperature showed significantly high correlation whereas the correlations for the net radiation energy, surface temperature, and wind speed were very low. These results appear to be affected by excessive or under estimation of solar and terrestrial radiation and climatic conditions of the surrounding areas and characteristics of land cover. Hence, these factors should be considered when applying these findings in urban and environment planning for improving the microclimate in urban areas.

Growth Characteristics of Trees following Different Types of Cutting in Quercus acutissima Stand (상수리나무 임분 내에서 벌채 유형에 따른 조림목의 생장 특성)

  • Shin, Yu-Seung;Song, Sun-Hwa;Yang, A-Ram;Hwang, Jaehong;Park, Yong Mok
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1075-1083
    • /
    • 2014
  • The objective of this study was to evaluate the effect of cutting types on microclimate and growth characteristics of afforested tree in Quercus acutissima stand after different types of cutting. The difference in temperature reaching $5.2^{\circ}C$ was shown in between clear cutting and selective cutting treatments. On July and August days with temperatures more than $35^{\circ}C$ often appeared in clear cutting stand. The values of VPD in July and August were higher than those in other months. Maximum VPD of 3.99 kPa was shown in clear cutting stand on May 23 as a prolonged rainless days appeared. However, VPD in selective cutting stand always stayed under 3.0 kPa throughout growing season. A higher intensity was shown in clear cutting and strip clear cutting stands, reaching to more than $1,600{\mu}mol\;m^{-2}s^{-1}$ at midday on early August, while that in selective cutting stand stayed about 1,500. In relative growth rate selective cutting stand showed a significantly higher relative growth rate in plant height than those in other cutting stands (p<0.05). The number of leaf in current-year branches significantly increased in selective cutting stand, whereas no increase was shown in clear cutting and strip clear cutting stands (p<0.05). In addition, relative elongation rate of current year branch also showed higher values in selective cutting stand compared with that in strip clear cutting stand (p<0.05). However, leaf mass per unit area (LMA) was higher in order of strip clear cutting, clear cutting, and selective cutting stands. From these results it is concluded that environmental conditions in clear cutting and strip clear cutting stands during growing season are more stressful to afforested tree species, resulting in lower relative growth in plant height, elongation of current-year branches, and leaf number per branch compared with those in selective cutting stand. Consequently, more data must be accumulated in the field to find out best cutting type in plantation considering the adaptational characteristic of each tree species varies with species and life span of tree is long.

Growth and Water Use Efficiency of Major Tree Species for Rehabilitation and the Impacts of Planting Trees on Microclimate Condition in Central Dry Zone of Myanmar (미얀마 건조지에서 주요 조림 수종의 생장과 수분이용효율 특성 및 조림이 건조지의 미세기상변화에 미치는 영향)

  • Park, Go Eun;Kim, Chan Beom;An, Jiae;Thang, Tluang Hmung;Maung, Wai Phyoe;Wai, Khaing Hsu;Kwon, Jino;Park, Chanwoo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.327-336
    • /
    • 2016
  • The Bagan, the central part of Myanmar, is dry zone where the mean annual precipitation is less than 600 mm for the last ten years. Forest in this region has been degraded due to biotic and abiotic disturbances. While there have been various efforts to rehabilitate the degraded area, the information on growth and physiological characteristics of planting species and the impacts of planting trees in the region still lacks. Therefore, this study was conducted to determine the growth and physiological water use efficiency characteristics of five species (Azadirachta indica A. Juss., Acacia catechu Willd., Eucalyptus camaldulensis Dehn., Acacia leucophloea (Roxb.) Willd. and Albizia lebbek (L.) Willd.) which are utilized as rehabilitation species in the dry zone and to identify the impacts of tree planting on microclimate change in dry zone. The growth and the foliar carbon isotope composition of seedlings and the above mentioned five species planted in 2005 were measured. And from February 2015 to January 2016, microclimatic factors air temperature and relative humidity at 60 cm and 2 m above soil, soil temperature, soil water contents and precipitation were measured at every 30-minute interval from the two weather stations installed in the plantation located in Ngalinpoke Mt. Range. One was established in the center of A. indica plantation, and the other was in the barren land fully exposed to the sunlight. Among the five species, A. indica and A. lebbek which showed higher water use efficiency could be recommended as rehabilitation species in dry zone. Planting trees in the dry area was shown to affect the change of microclimate with shading effects, declining temperature of the land surface and aridity of the air, and to contribute to conserving more water in soil by preventing direct evaporation and containing more water with fine roots of trees.

Thermoregulatory Responses in the Elderly and the Young under the Ondol System (온돌난방에서 노인과 청년의 피부온 반응 비교)

  • 정유정;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF

Preparation and Physical Characteristics of High-Performance Heat Storage.Release Fabrics with PCMMc : Wet coating process (상전이 마이크로캡슐이 함유된 고기능성 축열.발열 직물의 제조 및 물리적 특성 : 습식코팅)

  • Koo, Kang;Choe, Jong-Deok;Choi, Jong-Suk;Kim, Eun-Ae;Park, Young-Mi
    • Textile Coloration and Finishing
    • /
    • v.19 no.1 s.92
    • /
    • pp.24-30
    • /
    • 2007
  • Heat storage/release system in textile is a useful tool to increase energy efficiency and enhance comfortable microclimate of clothing. Phase change materials(PCM) are used in regulating storage and release properties of thermal energy. To investigate the temperature regulating ability of fabrics with PCM microcapsule(PCMMc), Nylon fabrics were coated with PCMMc via wet processing and they were characterized by SEM, DSC and infrared thermal analyzer. Also, water moisture transpiration, water penetration resistance, peel strength and washing durability of the fabrics were assessed. The water vapor permeation and water penetration resistance decreased with increasing PCMMc content. In DSC analysis, it can be seen that the microencapsulated fabric showed both exothermic md endothermic phenomena at specific temperature. Peel strength was decreased with increasing PCMMc content.

A Study on Distribution Characteristics of Corylopsis coreana Using SDM (종분포모형을 이용한 히어리 서식지의 분포 특성 연구)

  • Kwon, Hyuksoo;Ryu, Ji-Eun;Seo, Changwan;Kim, Jiyeon;Lim, Dong-Ok;Suh, Min-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.735-743
    • /
    • 2012
  • Since the CBD(Conservation on Biological Diversity)'s 10th Conference of the Parties adopted the protocol on access to genetic resources and benefit sharing in Nagoya 2010, the importance of endangered species studies such as habitat distribution, protection and management have been more emerged. Corylopsis coreana, an endangered species in Korea, was isolated nationally and has been damaged by anthropogenic factors. In this paper, we identified the factors affecting C. coreana habitat at the national scale and regional scale using National Survey of Natural Environment and predicted the distribution of C. coreana. Annual precipitation, precipitation of wettest quarter, temperature seasonality and Digital Elevation Model(DEM) were derived as important factors at the national scale, and precipitation of wettest quarter, DEM and solar radiation on spring were identified as important factors at regional scale. Colylopsis distribution was affected by an effect of climate significantly at the national scale, and by additionally the microclimate and topography at regional scale. These findings will be used as the basis on habitat conservation and restoration plan and climate change.

Green and Healthy Living in a High-rise, High Density Urban Environment: The Hong Kong Housing Authority's Experience

  • Fung, Ada Y.S.
    • Land and Housing Review
    • /
    • v.5 no.3
    • /
    • pp.131-136
    • /
    • 2014
  • The Hong Kong Housing Authority (HKHA) develops and implements a public housing programme to meet the housing needs of people who cannot afford private rental housing. The HKHA has an existing stock of about 740,000 public rental flats (PRH). According to the 2014 Policy Address, the Government aims to provide an average of about 20,000 PRH units and about 8,000 Home Ownership Scheme (HOS) units per year. We care for the environment. In developing new housing estates, we conduct thorough environmental studies such as microclimate studies and air ventilation assessment, and use passive design to harness the natural characteristics of our sites. We employ environment-friendly design and construction methods, using modular flat design, pre-cast and pre-fabricated construction techniques as well as recycled, green construction materials. We conduct Carbon Emission Estimation for all our projects, conserve the use of natural resources and reduce wastes throughout the life cycle of buildings. We care for people. We adopt the principles of Universal Design and Barrier Free Access for the convenience and welfare of people of all ages and abilities. We carry out Community Engagement to collect stakeholders' views and aspirations, and incorporate them in the design of our projects. We also carry out surveys of residents' views after the occupation of new estates to gauge our success and identify areas for improvement.

A Study on Microclimate Change Via Time Series Analysis of Satellite Images -Centered on Dalseo District, Daegu City- (위성영상의 시계열 분석을 통한 미기후변화 분석 -대구시 달서구를 대상으로-)

  • Baek, Sang-Hun;Jung, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.34-43
    • /
    • 2009
  • Based on previous research on ways of reducing an urban heat island phenomenon via an introduction of wind corridors, I conducted this study to see what influence a change in land cover arising of or going through urbanization has on wind corridors of urban space. As a target place, I chose Daegu city where is a representative extreme heat place in Korea and has been also largely expanded in size by incorporating its neighboring areas since the 1980s, expecially Dalseo District whose surface temperature gap is large. The population of Dalseo District has been sharply increased since its creation as a new administrative district in 1988. I studied on the urban microclimate change for a 20-year period by using satellite images on summer months in 1987, 1997 and 2007 in time frames. The finding of this study found that a reduction of natural land cover and an increase of artificial land cover serves as a disadvantageous factor for cold air creation and flowing and strikingly lowers the amount and height of cold air in the downtown area. It seemed that the cold air creation and flowing functions are influenced by land cover. In order to steadily create cold air and secure its flowing, it is thought that urban development or urban regeneration should be implemented by analysing the characteristics of the space surrounding the city. By doing so, a pleasant and healthy city could be formed.

  • PDF