• 제목/요약/키워드: Micro-titanium mesh

검색결과 8건 처리시간 0.026초

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

  • Choi, Tae Joon;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • 제43권1호
    • /
    • pp.84-87
    • /
    • 2016
  • Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

Micro-titanium mesh를 이용한 상악골 결손부의 재건술에 관한 연구 (THE RECONSTRUCTION OF THE MAXILLARY WALL DEFECT USING MICRO-TITANIUM MESH)

  • 김성곤;최유성;정필훈;이희철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권2호
    • /
    • pp.197-203
    • /
    • 2000
  • Maxillary defect may be induced by trauma, inflammation, cyst, tumor and surgical procedure. In case of limited wall defect, free bone graft has been preferred. But it has some problems such as postoperative bone resorption and soft tissue inclusion to recipient site. And we can not use free bone in the case who has inflammation in the donor site. So we used the micro-titanium mesh as reconstructive material for the maxillary wall defect. We had operated 8 patients who were diagnosed as maxillary partial defects from June 1997 to September 1998 in the Chin-Hae military hospital. They were 1 case of antral wall defect, 1 case of palatal wall defect, 5 cases of infra-orbital wall defects and 1 case of oroantral fistula case. As a result, the micro-titanium mesh has shown the morphological stability and biocompatibility and it could be used in case who has infection. And mesh structure could prevent soft tissue ingrowth to bony defect area. Thus it can be used to the case of maxillary partial defect successfully.

  • PDF

Micro-titanium mesh를 이용한 안와저 골절의 외과적 처치에 대한 연구 (TREATMENT OF THE 'BLOW-OUT' FRACTURE USING MICRO-TITANIUM MESH)

  • 김성곤;전영두;윤경인
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권3호
    • /
    • pp.312-316
    • /
    • 1999
  • When the external force was applied to the orbit the most thin area might be displaced. These were usually orbital floor and/or medial wall of orbit. Among these cases some who showed the entrapment of the muscle between the fractured fragments needed the surgical treatment. We had operated 4 cases of the "blow-out" fracture via subciliary approach. The entrapped muscles were freed from fragments and the bony defect was restored with micro-titanium mesh. Mean follow-up periods was 15 months and there were no complication observed.

  • PDF

안와 파열 골절 치료 시 삽입물 종류에 따른 후유증 비교 (Comparison of Sequelae According to the Types of Implants in Blow-Out Fracture)

  • 김태곤;임종효;이준호;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.23-28
    • /
    • 2009
  • Purpose: Blow out fracture can present tenderness, swelling, enophthalmos, extraoccular muscle limitation, paresthesia, diplopia according to severity of injury, so reconstruction of blow out fracture is important. Orbital soft tissue should be in orbit and defected orbital wall should be corrected by autologus tissue or alloplastic implants. Every implants have their merits and faults, every implants are used various. This study was designed to compare the sequelae of blow-out fracture repair using the alloplastic implants: micro-titanium mesh(Micro Dynamic titanium $mesh^{(R)}$, Leibinger, Germany), porous polyethylene ($Medpor^{(R)}$, Porex, USA), absorbable mesh plate(Biosorb $FX^{(R)}$ . Bionx Implants Ltd, Finland). Methods: Between January 2006 and April 2008, 52 patients were included in a retrospective study analysing the outcome of corrected inferior orbital wall fracture with various kind of implants. Implants were inserted through subciliary incision. Twenty patients were operated with micro-titanium mesh, fourteen patients with porous polyethylene and eighteen patients with absorbable mesh plate. In comparative category, enophthalmos, diplopia, range of motion of extraoccular muscle, inferior orbital nerve injury were more on frequently statistically in patients. Results: Fourteen of 18 patients underwent surgical repair to improve diplopia, 11 of 17 patients to improve parasthesia, 11 of 15 patients to improve enophthalmos, 8 of 9 patients to improve extraoccular muscle limitation. Duration of follow-up time ranged from 6 months to 12 months(mean, 7.4 months). There was no statistic difference of sequelae between micro titanium mesh and porous polyethylene and absorbable mesh plate in blowout fracture, inferior wall. Conclusion: There is no difference of sequelae between micro-titanium mesh, porous polyethylene and absorbable mesh plate in blow-out fracture, inferior wall. The other factors such as defect size, location, surgeon's technique, may influence the outcome of blow-out fracture repair.

Titanium Micro-mesh의 개형을 통한 하벽부 안와골절의 재건 (The Inferior Orbital Wall Reconstruction by Titanium Micro-mesh Remodeling)

  • 김한구;최민석;김우섭;배태희
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The inferior orbital wall is the most vulnerable to injury and inadequate reconstruction of inferior orbital fracture result in postoperative complications include enophthalmos, ocular dystopia and diplopia. Although the anatomical reconstruction of the inferior orbital wall is necessary to prevent these complications, the complexity of inferior orbital wall makes it difficult. We fabricated and remodeled the titanium micro-mesh plate for the anatomical reconstruction of inferior orbital wall. Methods: Twenty-nine patients with inferior orbital wall blow-out fracture were operated and twelve of them presented large extensive fracture. We intraoperatively fabricated and remodeled the Titanium-micro mesh to angulated lazy S shape similar to contralateral uninjured orbit. The preoperative and postoperative facial CT scan verified the 3-dimensional and anatomical reconstruction of the fractures. The mean follow-up was 19.7 months and postoperative complications was evaluated. Results: All cases showed the exact anatomical reconstruction, but there were minor complications in two cases. one patient had postoperative diplopia until 3months after surgery and the other patient had persistent enophthalmos (2 mm), but no further surgical correction was required. Conclusion: The comprehensive understanding of orbital convexity is the most important factor for anatomical reconstruction of inferior orbital fracture. We could prevent postoperative complications after inferior orbital wall reconstruction by intraoperative fabrication and anatomical remodeling of Titanium micro-mesh.

두개안면골 결손부 재건에 있어서 티타늄 그물판의 임상적 유용성 (Clinical Usefulness of Titanium Mesh in Reconstruction of the Craniofacial Bone Defects)

  • 서영민;정승문
    • Archives of Plastic Surgery
    • /
    • 제33권6호
    • /
    • pp.688-694
    • /
    • 2006
  • Purpose: Reconstruction of the craniofacial defects can be carried out with autogenous tissues, allogenic implants, or alloplastic materials. Titanium mesh systems have been used for bony reconstruction in non load-bearing areas. They offer several advantages: immediate availibility without any donor site morbidity, easy handling, stable 3-D reconstruction, and low susceptibility to infection. The aim of this study is to evaluate the usefulness and complications of titanium mesh system in the reconstruction of the craniofacial defects. Methods: From Jan. 2000, to Dec. 2004, we performed reconstruction of craniofacial bone defects in 21 patients who had benign or malignant tumor and fracture events in the cranium, orbit, nasal bone, maxilla, zygoma and the mandible. The size of the defects ranged from $1.0{\times}1.5cm$ to $12{\times}10cm$. Two different mesh systems, micro-titanium augmentation mesh and dynamic mesh was used for bony reconstruction in non load-bearing areas. The patients were evaluated from 1 to 4 yrs clinically and radiographically with a mean follow up period of 1.5 yrs. Results: There were no serious complications, including wound infection, foreign body reaction, exposures or loos of the mesh, central infection and pathologic findings of bone around mesh exception of one patient, who had expired of skull base tumor recurrence. Long-term stability of the reconstructions and the overall functional and aesthetic outcome was excellent. Conclusion: Our experiences demonstrate that the Titanium mesh system is a relatively safe and efficient method in the craniofacial reconstruction and have broadens our choices of therapeutic procedures in the craniomaxillofacial surgery.

스텝모터 구동형 짐벌 안테나의 미소진동저감을 위한 초탄성 형상기억합금 메쉬 와셔 기어의 기본특성 분석 (Characteristics Analysis of a Pseudoelastic SMA Mesh Washer Gear for Jitter Attenuation of Stepper-actuated Gimbal-type Antennas)

  • 박연혁;유창목;오현웅
    • 항공우주시스템공학회지
    • /
    • 제12권2호
    • /
    • pp.46-58
    • /
    • 2018
  • 고해상도 관측위성의 대용량 영상 데이터 송신용인 2축 짐벌식 X-밴드 안테나는 궤도 임무수행 중 안테나 구동에 따라 미소진동을 유발하며, 이는 관측위성의 영상 품질을 저하시키는 요인 중 하나이기 때문에 반드시 절연되어야 할 대상이다. 본 논문에서는 상기 X-밴드 안테나의 방위각 구동에 따른 미소진동절연과 동시에 기존에 제안된 티타늄 블레이드 기어가 소성변형에 취약한 문제점을 보완하기 위해 초탄성 형상기억합금 (SMA)을 활용한 메쉬 와셔 기어를 제안하였다. 상기 SMA 메쉬 와셔 기어의 기본 특성을 파악하기 위해 SMA 메쉬 와셔 두께방향 정하중 시험과 SMA 메쉬 와셔 기어 수준의 회전방향정하중 시험을 실시하였다. 아울러 안테나 조립체 수준의 미소진동 측정시험을 통해 제안된 SMA 메쉬와셔 기어의 진동절연이 효과적임을 입증하였다.

ATO 처리후, 플라즈마 전해 산화 처리된 Ti-6Al-4V 합금의 표면 형태 (Surface Morphology of PEO-treated Ti-6Al-4V Alloy after Anodic Titanium Oxide Treatment)

  • Kim, Seung-Pyo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.75-75
    • /
    • 2018
  • Commercially pure titanium (CP-Ti) and Ti-6Al-4V alloys have been widely used in implant materials such as dental and orthopedic implants due to their corrosion resistance, biocompatibility, and good mechanical properties. However, surface modification of titanium and titanium alloys is necessary to improve osseointegration between implant surface and bone. Especially, when titanium oxide nanotubes are formed on the surface of titanium alloy, cell adhesion is greatly improved. In addition, plasma electrolytic oxide (PEO) coatings have a good safety for osseointegration and can easily and quickly form coatings of uniform thickness with various pore sizes. Recently, the effects of bone element such as magnesium, zinc, strontium, silicon, and manganese for bone regeneration are researching in dental implant field. The purpose of this study was researched on the surface morphology of PEO-treated Ti-6Al-4V alloy after anodic titanium oxide treatmentusing various instruments. Ti-6Al-4V ELI disks were used as specimens for nanotube formation and PEO-treatment. The solution for the nanotube formation experiment was 1 M $H_3PO_4$ + 0.8 wt. % NaF electrolyte was used. The applied potential was 30V for 1 hours. The PEO treatment was performed after removing the nanotubes by ultrasonics for 10 minutes. The PEO treatment after removal of the nanotubes was carried out in the $Ca(CH_3)_2{\cdot}H_2O+(CH_3COO)_2Mg{\cdot}4H_2O+Mn(CH_3COO)_2{\cdot}4H_2O+Zn(CH_3CO_2)_2Zn{\cdot}2H_2O+Sr(CH_2COO)_2{\cdot}0.5H_2O+C_3H_7CaO_6P$ and $Na_2SiO_3{\cdot}9H_2O$ electrolytes. And the PEO-treatment time and potential were 3 minutes at 280V. The morphology changes of the coatings on Ti-6Al-4V alloy surface were observed using FE-SEM, EDS, XRD, AFM, and scratch tester. The morphology of PEO-treated surface in 5 ion coating solution after nanotube removal showed formation or nano-sized mesh and micro-sized pores.

  • PDF