• 제목/요약/키워드: Micro-strip line

검색결과 35건 처리시간 0.032초

탄성표면파 듀플렉서용 마이크로 스트립라인 집중소자 해석 및 실험 (Analysis and Experiment of Micro-strip Line Lumped Elements for SAW Duplexers)

  • 이승희;노용래
    • 한국전기전자재료학회논문지
    • /
    • 제15권1호
    • /
    • pp.85-92
    • /
    • 2002
  • In this study, we analyzed and experimented micro-strip line inductors and capacitors for a SAW duplexer, an important devise for mobile communication. For SAW duplexers, micro-strip line lumped elements must have small impedance values, below several tens of nH or several tens of pF, and a small area pattern. In this study, we performed theoretical analysis of flat line type, meander line type, and spiral line type inductors and interdigital capacitors on a LiTaO$_3$ Piezo-crystal. We proposed a measurement method to evaluate small values of lumped elements accurately with network analyzer. In experiments, we confirmed validity of the theoretical analysis method through fabrication and characterization of micro-strip line lumped elements. The analysis method in this paper can be applied to SAW duplexers well as other microwave devices.

마이크로 스트립라인 집중소자를 이용한 일체형 SAW 듀플렉서의 최적설계 및 실험 (Optimal Design and Experiment of One Chip Type SAW Duplexers using Micro_Strip Line Lumped Elements)

  • 이승희;노용래
    • 한국전기전자재료학회논문지
    • /
    • 제16권7호
    • /
    • pp.647-655
    • /
    • 2003
  • Commonly used SAW duplexers have a difficulty on manufacture so that a transmission line is printed on the package or an LTCC multi-layer is needed because a quarter-wave transmission line which is a kind of an isolation network is applied to the SAW duplexers. In this study, new structures of one chip type SAW duplexers are proposed. In the proposed structure, Tx and Rx SAW ladder filters and isolation networks are located on a single 36LiTaO$_3$ piezoelectric substrate. The manufacture process is very simple than commonly used product. It is possible to improve tile performance by means of optimizing the micro-strip line lumped elements. It is easy to integrate and modulate with other surrounding components. The optimal design techniques can be applied to other kind of multi-port devices.

접지가 있는 MCS 선로를 이용한 스텝 임피던스 저역 필터 (Stepped Impedance LPF Using MCS Line with Ground)

  • 이승엽;이용국
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1248-1253
    • /
    • 2008
  • 본 논문은 접지가 있는 비대칭 CPW(Coplanar Waveguide) 선로를 conformal mapping 방법을 사용하여 해석하였다. 이 방법으로 선로의 준정전계 특성 파라미터인 특성 임피던스와 유효 유전율을 계산하였다. 계산된 결과는 상용 프로그램인 IE3D의 결과와 기존 실험값과 비교했으며, 거의 일치함을 보였다. 그리고 본 논문에 해석한 접지가 있는 비대칭 CPW(MCS: Micro Coplanr Strip) 선로를 이용하여 스텝 임피던스 저역 필터에 적용하였다. 제작된 스텝 임피던스 저역 필터는 일반 마이크로스트립 선로로 구현된 저역 필터 특성과 비교하였다. 제작된 필터의 실험 결과를 모의실험과 비교하여 잘 일치함을 확인하였다.

마이크로 스트립라인 집중소자를 이용한 일체형 탄성표면파 듀플렉서 필터의 최적설계 (Optimal Design of a One-chip-type SAW Duplexer Filter Using Micro-strip Line Lumped Elements)

  • 이승희;이영진;노용래
    • 한국음향학회지
    • /
    • 제20권3호
    • /
    • pp.83-90
    • /
    • 2001
  • 기존의 탄성표면파 듀플렉서 필터는 1/4 파장 정합선로를 이용한 격리회로를 이용하기 때문에 패키지 상에 스트립 라인을 구성하는 제작상의 어려움이 있다. 송수신 필터와 격리회로를 따로 제작하여 조립하기 때문에 제작공정 또한 복잡하다. 본 연구에서는 격리회로가 송신용, 수신용 필터와 함께 하나의 단일 칩 위에 위치할 수 있는 새로운 형태의 탄성표면파 듀플렉서 필터를 설계하였다. 이러한 형태의 듀플렉서를 구성하기 위하여, 개별 탄성표면파 사다리형 필터와 집중소자인 인덕터와 캐패시터로 구성되는 격리회로망을 설계하였고, 듀플렉서의 전체 성능을 최적화할 수 있는 적절한 목표함수를 세워, 이를 비선형 다차원 최소화 방법을 통하여 최적화하였다. 그 결과 상용제품보다 더 우수한 성능이 구현됨을 확인하였다.

  • PDF

Etching-free 공정 적용 Micro filling 미세 패턴 구현 연구 (Study on fine pattern with Micro filling using Etching-free process)

  • 김완규;윤영우;이성의
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 추계총회 및 학술대회 논문집
    • /
    • pp.72-73
    • /
    • 2012
  • Metal line을 형성하는 방법에는 그라비아 인쇄, 잉크젯 인쇄, photo 공정 후 박막 증착 공정 등을 많이 사용한다. 본 연구에서는 Micro-imprinting 공정과 DFR photo lithography 공정을 통해 음각의 미세한 pattern을 형성한 후 sputtering과 printing을 이용하여 pattern의 filling을 통해 metal line을 구현하는 것을 목표로 하였다. Pattern을 형성한 후 RIE 공정을 통해 기판 표면의 친수성 처리를 하고, SAM 공정을 통해 코팅 막의 소수성 처리를 하였다. Sputtering과 전면 프린팅 및 건조 후 strip 공정을 통해 metal line을 형성하고, 이에 대한 표면 특성과 전기적 특성을 분석하였다.

  • PDF

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Electric Properties of Superconductors for Electric Power Transmission

  • Lee Sang-Heon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.211-213
    • /
    • 2005
  • [$SiO_2$] film coated as a passivation layer for YBCO based electronic devices is investigated by measuring the micro wave properties of micro strip line resonators. The $SiO_2$ film coated resonators are compared with coated resonators for two degradation conditions, a $200^{\circ}C$ annealing in air and an exposure to air at $85^{\circ}C\;85\%$ relative humidity. The $SiO_2$ film reduces the YBCO thin film degradation caused by oxygen stoichiometry change and reaction with water.

MCS선로를 이용한 스텝 임피던스 저역필터 (Stepped Impedance LPF using MCSl)

  • 이승엽;이성재;김온
    • 한국전자통신학회논문지
    • /
    • 제3권3호
    • /
    • pp.153-157
    • /
    • 2008
  • MCS(Micro-coplanar strip) 선은 전부터 분석되어 왔었다. 등각 지도로 나타낸 방법은 이 MCD 선의 준정적인 효과적인 유전율 그리고 독특한 임피던스를 산출하기 위하여 이용되곤 했다. 현재 이용되는 모든 성과들은 상업적인 S/W, IE3D를 사용하여 얻어진 결과와 비교할 때 유리한 계약에 있기 위해서이다. 그리고 이 부분에서, 적합한 임피던스 저역 원반꼴 안테나 여과기는 주파수 응답 개량을 위한 MCS 선으로 디자인되고 날조되었다. LPF는 구조는 또한 디자인되고 정지하여 있는 예리한 묶음성 특성이 유지하기 위하여 끈을 실행할 수 있도록 하였다. 가장 끝과 측량 결과에서의 결과는 실행한 LPF로 확인할 수 있다.

  • PDF

광대역 VHF 마이크로스트립 가변대역통과 여파기의 설계 (Design of Wide Band VHF Microstrip Tunable Band-Pass Filters)

  • 박병호;정용채;윤상원;장익수
    • 전자공학회논문지A
    • /
    • 제29A권10호
    • /
    • pp.24-28
    • /
    • 1992
  • A new design method of microstrip wide band VHF tunable bandpass filters using varacter diodes is presented. In the proposed filter both the input and output ports are coupled through capacitors, and an open micro-strip line is inserted between the coupled line in order to obtain the desired degree of coupling. The optimized filter responseses for the frequency range of 220-404MHz by TOUCH-STONE are compared with the measured ones.

  • PDF

X-대역 마이크로 스트? 방향성 결합기의 설계 (Design of X band Microstrip Directional Couplers)

  • 양인응;홍완희
    • 대한전자공학회논문지
    • /
    • 제12권4호
    • /
    • pp.7-14
    • /
    • 1975
  • 본 논문은 대칭 (단자 단로망이론을 근거로 분포정수 회로에 대한 매트릭스식에 의해서 결합기의 결합도와 특성임피던스간의 관계식을 얻어내었고 마이크로스트립 전송선로에 대한 칭전기학적 접근방식에 의해 등각사상법의 적용방식을 밝히고 경계치조건을 만족시키는 특성임피이던스식과 유전체 경계면상에서의 위상속도와 우수모드 및 기수모드 시의 유효유전율의 관계에 의해서 결합영역의 길이를 결정하는 식을 유도하였다. 결과식을 이용하여 원하는 방향성 결합기의 칫수를 콤퓨타 프로그램에 의하여 설계하였으며 설계한 결합기의 칫수에 따라 양면 유전체기판 Custom High K 707L-2.5을 사용하여 7개의 결합기를 제작하였다. 이 제작된 결합기는 실험에 의해서 이론치와 비교 고찰하였으며 10dB에서 20dB까지의 요구되는 결합기는 비교적 좋은 결과를 얻었다. A significant new technique in the dsvelopment of micro-wave circuits is the process of untilization of coupled lines in the transverse electro-magnetic field. The bases for this technique are the application of even-and odd-mode characteristic impedances of the transmission line. This article describes the properties of directional couplers and explains a prccfdure usrd to design micro-strip directional couplers with the aid of the computer. The article also describes the experimental results obtained from seven microstrip couplers, which were built to verify the computer program and the approximate solutions. It can be seen that in cases at X-band where couplings of 10 to 20dB are required, the computer program and approximate solutions will produce good results.

  • PDF