• Title/Summary/Keyword: Micro-particle

Search Result 739, Processing Time 0.027 seconds

New Fabrication method of Planar Micro Gas Sesnor Array (집적도를 높인 평면형 가스감지소자 어레이 제작기술)

  • 정완영
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.727-730
    • /
    • 2003
  • Thin tin oxide film with nano-size particle was prepared on silicon substrate by hydrothermal synthetic method and successive sol-gel spin coating method. The fabrication method of tin oxide film with ultrafine nano-size crystalline structure was tried to be applied to fabrication of micro gas sensor array on silicon substrate. The tin oxide film on silicon substrate was well patterned by chemical etching upto 5${\mu}{\textrm}{m}$width and showed very uniform flatness. The tin oxide film preparation method and patterning method were successfully applied to newly proposed 2-dimensional micro sensor fabrication.

  • PDF

Micro-discharged plasma density, electron temperature and excited xenon density for enhancement of vacuum ultraviolet luminous efficiency in alternating current plasma display panel

  • Choi, Eun-Ha;Oh, Phil-Yong;Seo, Yoon-Ho;Cho, Guang-Sup;Uhm, Han-S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.161-166
    • /
    • 2005
  • The plasma ion density in AC-PDP has shown to be increased from $5.6{\times}10^{11}cm^{-3}$ to $9.0{\times}10^{11)cm^{-3}$ as the Xe mixture ratio to neon increase from 1 % to 10 %, respectively, at fixed pressure of 400 Torr, by using the micro-Langmuir probe. It is noted that the plasma ion density is density increases as the gas pressure increases in this experiment. The electron temperature decreases from 2.3 to 1.2 eV as the Xe mole fraction increases from 1 % to 10 % at fixed pressure of 400 Torr, which is measured by the micro Langmuir probe and high-speed ICCD camera in this experiment. It is noted that the electron temperature decreases as the gas pressure increases from 150 to 400 Torr in this experiment. It is also observed that the exited Xe atom density and the plasma ion density are in strong correlation sharp between each other in this experiment. It is noted that $5.2{\times}10^{12}cm^{-3}$ in the $1s_5$ metastable state and $1.2{\times}10^{12}cm^{-3}$ in the $1s_4$ resonance state for the PDP cell with gap of 50 um distances under the fixed gas pressure of 400 Torr and Xe content ratio of 10 %.

  • PDF

Investigation of chemical modification on tosyl-activated polystyrene microsphere magnetic particle surface by infrared microscopy (토실 활성화된 폴리스티렌 마이크로구체 자성 입자 표면의 화학적 변형에 대한 적외선 연구)

  • Byun, Chang Kyu
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.225-233
    • /
    • 2016
  • The chemical engrafting of polymers on particle surface, plays an important role on selective partitioning of micro/nano-particles in the separated layers of liquid media, such as aqueous two phase systems (ATPSs). Three polymers, dextran, poly (ethylene glycol) and albumin were chosen and chemically conjugated to the polystyrene (PS) magnetic microparticle surface. The attachment of long-chained polymer chains which may switch the partition behavior, can be simply performed by SN2 substitution of various polymers having primary amine functional groups, with p-toluenesulfonyl (tosyl)-activated polystyrene magnetic micro-particles. The surface modification of microparticle was probed by infrared microscopy. The distinctive peak represents N-H stretching vibration mode for microparticles after the reaction and it is common for all three polymers examined. The locations of main peaks are similar for all micro-particles but different and distinguishable in fingerprint region.

Micro- PIV Measurements of Microchannel Flows and Related Problems (마이크로 채널 내부 유동의 Micro-PIV측정과 제반 문제점)

  • Lee Sang-Joon;Kim Guk-bae
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.79-84
    • /
    • 2002
  • Most microfluidic devices such as heat sinks for cooling micro-chips, DNA chip, Lab-On-Chip, and micro pumps etc. have microchannels of various size. Therefore, the design of practical microfluidics demands detail information on flow structure inside the microchannels. However, detail velocity field measurements are rare and difficult to carry out. In addition, as the microfluidics expands, accurate understanding of microscale transport phenomena becomes very important. In this research, micro-PIV system was employed to measure the velocity fields of flow inside a micro-channel. We carried out PIV measurements for several microchannels with varying channels width, inlet and outlet shape, filters, CCD camera and ICCD camera, etc. For effective composition of micro-PIV system, first of all, it is essential to understand optics related with micro-imaging of particles and the particle dynamics encountered in micro-scale channel flows. In addition, it is necessary to find the optimal condition for given experimental environment and? micro-scale flow to be investigated. The problems encountered in measuring velocity field of micro-channel flows are discussed in this paper.

  • PDF

Electrical and Mechanical Strength Properties of Epoxy/Micro Silica and Alumina Composites for Power Equipment (전력기기용, 에폭시/마이크로 실리카 및 알루미나 복합제의 전기적·기계적 파괴 강도 특성)

  • Park, Joo-Eon;Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.7
    • /
    • pp.496-501
    • /
    • 2018
  • In this study, we prepared 40, 45, 50, 55, 60, 65, and 70 wt% content composites filled in epoxy matrix for two micro silica and three micro alumina types for use as a GIS heavy electric machine. As a filler type of epoxy composite, micro silica composites showed excellent AC breakdown strength properties compared to micro alumina composites in the case of electrical properties of micro silica and alumina. The electrical breakdown properties of micro silica composites increased with increasing filler content, whereas those of micro alumina decreased with increasing filler content. In the case of mechanical properties, the micro silica composite showed improved tensile strength and flexural strength compared with the micro alumina composite. In addition, mechanical properties such as tensile strength and flexural strength of micro silica and alumina composites decreased with increasing filler content. This is probably because O-H groups are present on the surface of silica in the case of micro silica but are not present on the surface of alumina in the case of micro alumina.

Development of Ultraprecision Finishing Technique using Bonded Magnetic Abrasives (결합된 자성연마입자를 이용한 초정밀 피니싱 기술 개발)

  • 윤종학;박성준;안병운
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.5
    • /
    • pp.59-66
    • /
    • 2003
  • This study suggests the new ultraprecision finishing techniques for micro die and mold parts using magnetic field-assisted polishing. Conventional magnetic abrasives have several disadvantages, which are missing of abrasive particle and inequal mixture between magnetic particle and abrasive particle. Therefore, bonded magnetic abrasive particles are fabricated by several method. For example, plasma melting and direct bonding. Carbonyl iron powder is used as magnetic particle there silicon carbide and alumina are abrasive particles. Developed magnetic abrasives are analyzed using SEM. Feasibility of magnetic abrasive and polishing performance of this magnetic abrasive particles also have been investigated. After polishing, surface roughness of workpiece is reduced from 85.4 ㎚ Ra to 9 ㎚ RA.

Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows (미세 생체유동 해석을 위한 첨단 유동가시화기법)

  • Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

An Electrical Particle Velocity Profiler Using Particle Transit Time Across Uneven Inter-Gap Electrodes (비등간격 전극열에서의 입자 통과시간을 이용한 전기적 입자속도분포 검출기)

  • Kim, Tae-Yoon;Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.4
    • /
    • pp.297-302
    • /
    • 2008
  • We present an electrical particle velocity profiler using particle transit time across uneven inter-gap electrodes. We measure both the particle position and velocity from the voltage signals generated by the particles passing across sensing electrodes, thus obtaining the velocity profile of the particles in a microfluidic channel. In the experimental study, we use polystyrene microparticles to characterize the performance of the electrical particle velocity profiler. The particle velocity profile is measured with the uncertainty of 5.44%, which is equivalent to the uncertainty of 5% in the previous optical method. We also experimentally demonstrate the capability of the present method for in-channel clogging detection. Compared to the previous optical methods, the present electrical particle velocity profiler offers the simpler structure, the cheaper cost, and the higher integrability to micro-biofluidic systems.

A Study on the Thermal Properties of Epoxy/Micro-Nano Alumina Composites, as Mixture of Surface Modified Nano Alumina (표면개질된 나노알루미나를 혼합한, 에폭시/마이크로-나노알루미나 콤포지트의 열적특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1504-1510
    • /
    • 2016
  • The aim of this study is to improve properties both glass transition temperature($T_g$) and coefficient of thermal expansion(CTE) using epoxy/micro-nano alumina composites with adding glycerol diglycidyl ether (GDE:1,2,3,5g). This paper deals with the effects of GDE addition for epoxy/micro alumina contents (40, 50, 60wt%)+surface modified nano alumina(1_phr) composites. 20 kinds specimen were prepared with containing micro, nano alumina and GDE as a micro composites(10, 20, 30, 40, 50, 60, 70wt%) or a nano/micro alumina composites(1phr/40, 50, 60wt%). Average particle size of nano and micro alumina used were 30nm and $1{\sim}2{\mu}m$, respectively. The micro alumina used were alpha phase with Heterogeneous and nano alumina were gamma phase particles of spherical shape. The glass transition temperature and coefficients of thermal expansion was evaluated by DSC and TMA. The glass transition temperature decreased and coefficients of thermal expansion become smaller with filled contents of epoxy/micro alumina composites. On the other hand, $T_g$ and CTE as GDE addition variation(1,2,3,5g) of epoxy/micro-nano alumina composites decreased and increased respectively.

Study of Deposition Mechanism of Al2O3 Films According to Al2O3 Particle Size via Aerosol Deposition Process (에어로졸 증착 공정을 통해 제작한 Al2O3 코팅층의 Al2O3 입자 크기에 따른 성막 메커니즘 연구)

  • Kim, Ik-Soo;Cho, Myung-Yeon;Koo, Sang-Mo;Lee, Dong-Won;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.219-224
    • /
    • 2020
  • Al2O3 powders with particle sizes of 0.35 ㎛, 0.5 ㎛, 1.5 ㎛, and 2.5 ㎛ are deposited onto glass and Cu substrates using the aerosol deposition (AD) process. The deposition characteristics of Al2O3 films using those four types of Al2O3 powders are investigated to determine the influence of the particle size on the films. To observe detailed micro-structures of the films, the cross-section and surface morphology are observed. Then, the crystalline size and internal strain are calculated from X-ray diffraction peaks in order to confirm the hammering effect as well as the micro-strain during the AD deposition. From the above results, deposition mechanisms related to the particle size are studied. The results of this study indicate the optimal particle size and formation mechanisms for dense Al2O3 film with a smooth surface roughness as well as for a porous Al2O3 film with a rough surface roughness.