• Title/Summary/Keyword: Micro-implant

Search Result 179, Processing Time 0.031 seconds

Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs

  • Ahn, Seok;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.75-84
    • /
    • 2009
  • STATEMENT OF PROBLEM. A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE. The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS. Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS. 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION. it is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.

A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A.) (Micro-Implant Anchorage(MIA)를 이용한 Sliding mechancis)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.677-685
    • /
    • 2000
  • Anchorage plays an important role in orthodontic treatment. Because of limited anchorage Potential and acceptance problems of intra- or extraoral anchorage aids, endosseous implants have been suggested and used. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period for osseointegration. Titanium miniscrews and microscrews were introduced as orthodontic anchorage due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and their ability to be placed in any area of the alveolar bone. In this study, a skeletal Class II Patient was treated with sliding mechanics using M.I.A.(micro-implant anchorage). The maxillary micro-implants provide anchorage for retraction of the upper anterior teeth. The mandibular micro-implants induced uprighting and intrusion of the lower molars. The upward and forward movement of the chin followed. This resulted in an increase of the SNB angle, and a decrease of the ANB angle. The micro-implants remained firm and stable throughout treatment. This new approach to the treatment of skeletal Class II malocclusion has the following characteristics . Independent of Patient cooperation. . Shorter treatment time due to the simultaneous retraction of the six anterior teeth . Early change of facial Profile motivating greater cooperation from patients These results indicate that the M.I.A. can be used as anchorage for orthodontic treatment. The use of M.I.A. with sliding mechanics in the treatment of skeletal Class II malocclusion increases the treatment simplicity and efficiency.

  • PDF

A compare research of machined implant and RBM surface implant (Machined 임플란트와 RBM surface 임플란트의 비교 연구)

  • Yoo, Im-Soo;Yim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.467-474
    • /
    • 2008
  • Purpose: To evaluate RBM surface implant which has its good character like that good initial stability, early bone formation. Material and Methods: In this study fixures have divided in 2 group: Machined(Group I), RBM(Group II). Total 10 fixtures were implanted on rabbit which sacrificed on week 2 and week 4 for the histological specimens. By these specimens polarized microscopic view, micro CT view, ISQ value were measured, compared and analysed by each group to figure out the evidence that clinical use of RBM implant. Result: ISQ value had no significance differences between 2 groups, However in each group 4, 8 weeks had higher ISQ value than 2 weeks. In polarized microscope, calcification level was following: Group II, Group I. In micro CT, formation of cancellous bone level was following: Group II, Group I. Conclusion: RBM implant was the most excellent on the early bone formation and good initial stability.

Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters (교정용 마이크로 임플란트의 디자인이 토오크와 파절강도에 미치는 영향)

  • Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.171-181
    • /
    • 2007
  • Objective: The present study was aimed at an analytical formulation of the micro-implant related torque as a function of implant size, i.e. the diameter and length, screw size, and the bony resistance at the implant to bone interface. Methods: The resistance at the implant to cancellous bone interface $(S_{can})$ was assumed to be in the range of 1.0-2.5 MPa. Micro-implant model of Absoanchor (Dentos Inc. Daegu, Korea) was used in the course of the analysis. Results: The results showed that the torque was a strong function of diameter, length, and the screw height. As the diameter increased and as the screw size decreased, the torque index decreased. However the strength index was a different function of the implant and bone factors. The whole Absoanchor implant models were within the safe region when the resistance at the implant/cancellous bone $(=S_{can})$ was 1.0 or less. Conclusion: For bone with $S_{can}$ of 1.5 MPa, the cervical diameter should be greater than 1.5 mm if micro-implant models of 12 mm long are to be placed. For $S_{can}$ of 2.0 MPa, micro-implant models of larger cervical diameter than 1.5 mm were found to be safe only if the endosseous length was less than 8 mm.

Smart Surface Texturing Implant Stem for Enhancement of Osteoblast Cell Biocompatibility (골육세포 성장 촉진을 위한 스마트 써피스 텍스처링 임플란트 스템 제작 기술)

  • Kim, Kyunghan;Lee, Jaehoon;Park, Jongkweon;Jin, Sukwon;Choi, Wanhae;Lee, Hongjin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.375-380
    • /
    • 2014
  • To enhance biocompatibility between the orthopedic implant stem and obsteoblast cells, bone-forming cells, micro-size holes are patterned in Ti plate surface. Initially, the house built laser power stabilization system is applied to the laser micro patterning machine to convince repeatable result. Various pulse widths are irradiated Ti plate and relationship between diameters of patterned holes and pulsed width is derived. Effect of multi pulse is observed and optimal pulse number is considered to avoid heat affected zone. After MG-63 osbeoblast cells are cultured, micro patterned Ti plates are compared with control plates. In SEM image, cells are well aligned and aggregation is observed in both 60, and $100{\mu}m$ patterned plates. Finally, free form surface stem model is prepared to test micro hole patterning.

Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study

  • Lee, Ji-Hyun;Kim, Hee-Jin;Yun, Jeong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.20-29
    • /
    • 2017
  • Purpose: The microstructural characteristics of trabecular bone were identified using micro-computed tomography (micro-CT), in order to develop a potential strategy for implant surface improvement to facilitate osseointegration. Methods: Alveolar bone specimens from the cadavers of 30 humans were scanned by high-resolution micro-CT and reconstructed. Volumes of interest chosen within the jaw were classified according to Hounsfield units into 4 bone quality categories. Several structural parameters were measured and statistically analyzed. Results: Alveolar bone specimens with D1 bone quality had significantly higher values for all structural parameters than the other bone quality categories, except for trabecular thickness (Tb.Th). The percentage of bone volume, trabecular separation (Tb.Sp), and trabecular number (Tb.N) varied significantly among bone quality categories. Tb.Sp varied markedly across the bone quality categories (D1: $0.59{\pm}0.22mm$, D4: $1.20{\pm}0.48mm$), whereas Tb.Th had similar values (D1: $0.30{\pm}0.08mm$, D4: $0.22{\pm}0.05mm$). Conclusions: Bone quality depended on Tb.Sp and number-that is, endosteal space architecture-rather than bone surface and Tb.Th. Regardless of bone quality, Tb.Th showed little variation. These factors should be taken into account when developing individualized implant surface topographies.

Development and Evaluation for the Micro-Movement Structure of Interspinous (척추극돌간 미세움직임 재현 보형물의 개발 및 평가)

  • Park, Joon-Sik;Seo, Tae-Il;Bae, Jong-Suk;Yoon, Gil-Sang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.3
    • /
    • pp.127-131
    • /
    • 2006
  • Existing orthopedic implants such as pedicle screw and spinal cage were designed to fix the spinal structure. But, nowadays, physicians want to rehabilitate there original functions. To achieve this request, we studied micro-movable structure for interspinous. As a first step, we designed interspinous structure by 3D CAD to join each spinous processes. Next, we simulate it with various factors such as the thickness of micro-movement structure and the design of clip. At last, we performed static compressive test to satisfy the failure load of 339N and dynamic endurance test of 1.2M cycle. As a result, we developed interspinous implant and did several surgery to evaluated its satisfaction.

Micromorphometric change of Ti$O_2$ blast implant surface conditioned with tetracycline-HCI (산화 티타늄 블라스팅 임프란트 표면구조에 대한 염산 테트라싸이클린의 영향)

  • Lee, Jung-Min;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk;Heo, Seong-Joo
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.599-611
    • /
    • 2007
  • The present study was performed to evaluate the surface roughness and effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Ti$O_2$ surface Implant was utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for 0.5min, 1min, 1.5min, 2min, 2.5min and 3min respectively in the Tetracycline-HCI group. Then, specimens were measured surface roughness and processed for scanning electron microscopic observation. The results of this study were as follows. 1. Ti$O_2$ blast implant surface showed increased surface roughness 1.5 minute after treatment with Tetracycline-HCI. But, there were not significant differences in saline group after treatment. 2. Tetracycline-HCI group showed changed surface micro-morphology in SEM after 1.5 minute. There were not significant differences in saline group after treatment. 3. Between Tetracycline-HCI group and saline group, there were difference in surface roughness change and SEM micro-morphology. Tetracycline-HCI have influence on Ti$O_2$ blast implant surface. In conclusion, the detoxification with 50mg/ml Tetracycline-HCI must be applied respectively with different time according to various implant surfaces.