Browse > Article

Development and Evaluation for the Micro-Movement Structure of Interspinous  

Park, Joon-Sik ((의)장산의료재단 이춘택병원 로봇관절연구소)
Seo, Tae-Il (인천대학교 기계공학과)
Bae, Jong-Suk (인천대학교 대학원 기계공학과)
Yoon, Gil-Sang (한국생산기술연구원 정밀금형팀)
Publication Information
Transactions of the Korean Society of Machine Tool Engineers / v.15, no.3, 2006 , pp. 127-131 More about this Journal
Abstract
Existing orthopedic implants such as pedicle screw and spinal cage were designed to fix the spinal structure. But, nowadays, physicians want to rehabilitate there original functions. To achieve this request, we studied micro-movable structure for interspinous. As a first step, we designed interspinous structure by 3D CAD to join each spinous processes. Next, we simulate it with various factors such as the thickness of micro-movement structure and the design of clip. At last, we performed static compressive test to satisfy the failure load of 339N and dynamic endurance test of 1.2M cycle. As a result, we developed interspinous implant and did several surgery to evaluated its satisfaction.
Keywords
Spinal Cage; Micro-movement; Interspinous; Medical; Implant; Finite Element Method; Ti-6Al-4V; Orthopaedics;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Herzog, R. J., Wiens, J. J., Dillingham, M. F. and Sontag, M. J., 1991, 'Normal cervical spine morphometry and cervical spinal stenosis in asymptomatic professional football players. Plain film radiography, multiplanar computed tomography, and magnetic resonance imaging,' Spine, 16, pp. 178-186   DOI
2 Metals Handbook Vol. 2 - Properties and Selection: Nonferrous Alloys and Special-Purpose Materials, 1990, ASM International 10th Ed
3 Kim, K. T., Lee, S. U., Kim, Y. W., Hong, G. P. and Mun, M. S., 1998, 'A Biomechanical Study of Screw Designs of Transpedicular Screw on the Fixation Strength,' J. of Korean Orthop Assoc, 33, pp. 350-707
4 Duncan, E. T. S., Johanna, C. L. and Katharine, J. M., 2000, 'Spinous Process Strength,' SPINE, Vol. 25, No. 3, pp. 319-323   DOI   ScienceOn
5 Suk, S. I., 1997, Spinal Surgery, Newest Medical Publisher, pp. 32-48
6 Boyer, R., Welsch, G. and Colling, E. W., 1994, Materials Properties Handbook: Titanium Alloys, eds. ASM International, Materials Park, OH
7 Hong, H. P., Oh, S. H. and Seo, N. S., 1989, 'A Study on the Machinability of Titanium,' KSPE, Vol. 6, No. 1, pp. 45-51
8 Gupta, S. K., Roy, R. C. and Srivastava, A., 1982, 'Sagittal diameter of cervical canal in normal Indian adults,' Clin Radiol 33, pp. 681-685   DOI   ScienceOn
9 George, T. R., 1980, An orthopaedist looks at finite element analysis, Finite elements in biomechanics, John Wiley & Sons Ltd, 1st ed., pp. 1-7
10 Lim, J. K. and Wong, H. K., 2004, 'Variation of the cervical spinal Torg ratio with gender and ethnicity,' The Spine Journal 4, pp. 396-401   DOI   ScienceOn