• 제목/요약/키워드: Micro-gas Turbine

검색결과 140건 처리시간 0.026초

Characteristics of a Coupled Gas Lubricated Bearing for a Scaled-Up Micro Gas Turbine

  • Lee, Yong Bok;Kwak, Hyunduck;Kim, Chang Ho;Jang, Gun Hee
    • KSTLE International Journal
    • /
    • 제1권2호
    • /
    • pp.107-112
    • /
    • 2000
  • In case of the limitation of Deep RIE fabrication far Micro Gas Turbine, bearing aspect ratio is limited in very small value. The characteristics such as pressure distribution, load capacity and non-linearity of a short bearing of L/D=0.083 and a conventional bearing of L/D=1.0 with coupled boundary effects are investigated for Micro Gas Turbine bearings. The coupled effect was analyzed by mass conservation at coupled end area. The results, increasing load capacity and non-linearity due to the coupled effect of thrust and journal bearing, are obtained and the selection of journal bearing type is discussed.

  • PDF

실험데이터 기반 마이크로 가스터빈엔진 탈 설계점 성능해석 (Off-design Performance Analysis based on Experimental Data of a Micro Gas Turbine Engine)

  • 김승재;최성만;이동호
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.64-71
    • /
    • 2018
  • 가스터빈엔진의 탈설계점 운전 성능해석을 수행하기 위해서는 구성품의 성능 특성을 파악하는 것이 필수적이다. 본 연구에서는 가스터빈의 성능특성을 이해하기 위하여 마이크로 가스터빈엔진 성능시험 장치를 구축하였다. 구축된 마이크로 가스터빈 시험 장치를 이용하여 엔진의 회전수에 따른 유동장내의 온도와 압력 데이터를 수집하였으며, 수집된 실험 데이터를 이용하여 압축기 성능선도를 구성하였다. 터빈 출구부에서 배기가스를 포집하여 연소효율을 계산하였다. 구성된 압축기 성능선도와 연소효율을 GasTurb 성능해석 소프트웨어에 적용하여 지상 정지시의 탈설계점 성능해석을 수행하였고, 측정된 엔진성능데이터와 비교분석을 수행하였다.

마이크로 가스터빈 열병합장치 성능특성 연구 (Study on the Performance Characteristics of Micro Gas Turbine (MGT) Co-generation System)

  • 허광범;김재훈
    • 한국소음진동공학회논문집
    • /
    • 제16권9호
    • /
    • pp.964-970
    • /
    • 2006
  • Micro gas turbine(MGT) has received attention recently as small-scale distributed power sources. With characteristics such as their small size, lightweight, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of ' applications, including residential and small-scale industrial use. It is very easier to start-up and stop the MGT system which is the friendly environmental power system has just below the 9ppm NOx emmission and good quality of noise level. The exhaust heat emitted by the MGT is in the form of about $300^{\circ}C$ clean exhaust gas. The exhaust gas is suitable for absorption chiller/heater system. 1 has researched performance characteristics of the 60 kW class MGT-absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated.

가스터빈-연료전지 혼합형 고효율 발전시스템 (High Efficiency Gas Turbine-Fuel Cell Hybrid Power Generation System)

  • 이진근;양수석;손정락;송락현;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.347-353
    • /
    • 2001
  • A combined cycle, 'HYBRID', is emerging as a new power generation technology that is particularly suitable for the distributed power generation system, with high energy efficiency and low pollutant emission. Currently micro gas turbines and fuel cells are attracting a lot of attention to meet the future needs in the distributed power generation market. This hybrid system may have every advantages of both systems because a gas turbine is synergistically combined with a fuel cell into a unique combined cycle. The hybrid system is believed to become a leading runner in the distributed power generation market. This paper introduces a current plan associated with the development of the hybrid system which consists of a micro gas turbine and a solid-oxide fuel cell(SOFC).

  • PDF

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • 제5권2호
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

200kW급 마이크로 가스터빈 시스템의 설계 변수 민감도 해석 (Design Parameter Sensitivity Analysis of a 200kW Class Micro Gas Turbine System)

  • 신현동;강도원;김동섭;최문경;박필제
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.39-45
    • /
    • 2012
  • This paper describes the outcome of the design of a 200 kW class micro gas turbine and the sensitivity of its performance (efficiency and power) to the variations in major design parameters. The reference design parameters were set up based on the best available component technologies. The resulting net electricity generation efficiency of the micro gas turbine package was found to be competitive to those of other systems in the market. The sensitivities of power and efficiency to the variations in compressor and turbine efficiencies, pressure ratio, turbine inlet temperature, recuperator effectiveness, secondary air ratio, pressure loss ratios of both the cold and hot sides of the recuperator were estimated. Based on the sensitivity data, a simplified method to predict the variation in system performance responding to the combinations of small changes in all design parameters were set up and validated.

Coupled Boundary Effects on a Gas Lubricated Bearing far a Scaled-Up Micro Gas Turbine

  • Hyunduck Kwak;Lee, Yong-Bok;Kim, Chang-Ho;Gunhee Jang
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.243-249
    • /
    • 2000
  • In case of the limitation of Deep RIE fabrication for Micro Gas Turbine, bearing aspect ratio is limited in very small value. The characteristics such as pressure distribution load capacity and non-linearity of a short bearing of L/D=0.083 and a conventional bearing of L/D=1.0 with coupled boundary effects are investigated far Micro Gas Tlubine bearings. The coupled efffect was analyzed by mass conservation at coupled end area. The results, increasing load capacity and non-linearity due to the coupled effect of thrust and journal bearing, are obtained and the selection of journal bearing type is discussed.

  • PDF

Numerical Analysis of Tip Clearance Effects in a Micro Radial Inflow Turbine

  • Watanabe, Naoki;Teramoto, Susumu;Nagashima, Toshio
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.622-627
    • /
    • 2004
  • There are many difficulties in realizing Ultra-micro gas turbine system. Among them, the effects of tip clearance upon the micro turbine flowfield are discussed in this paper. The flowfield was investigated numerically with the Reynolds-averaged three-dimensional thin-layer Navier-Stokes equations. Calculations were conducted with clearance height from 0% to 10% of the passage height. Leakage mass flow and deterioration of efficiency are proportional to the clearance height for the clearance height larger than 4%. However, in the case of 2% clearance, leakage flow is significantly reduced due to relative motion of the casing and as a result deterioration of efficiency is very small. It is difficult to control tip clearance in micro turbines, but the results of this study indicate that if the clearance height is controlled within a few per-cent of passage height, deterioration of stage performance will be small.

  • PDF

지열시스템이 포함된 빌딩마이크로그리드 시스템의 에너지성능평가 및 경제성분석 (Economic Evaluation of Building Micro-Grid Including Geothermal Energy System in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.273-277
    • /
    • 2009
  • This paper presents a basic energy performance data of micro gas turbine, Renewable Energy(BIPV and Solar Collector System, geothermal system) and a hybrid energy system(geothermal system and microturbine) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently, the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. Finally, in energy performance aspect, Micro gas turbine system and hybrid energy system were high-efficiency system in hospital building. Hybrid energy system also give us a powerful alternative energy system economically.

  • PDF

LabVIEW를 이용한 소형 가스터빈 엔진의 통합 시험장치 개발 (Development of a Integrated Modifiable Micro Gas Turbine Engine Test Rig using LabVIEW)

  • 강영수;김도헌;이인철;윤상훈;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.354-358
    • /
    • 2009
  • 소형 가스터빈 엔진은 무인 항공기 및 소규모 비상 발전 시스템의 동력 기관으로서 각광받고 있으며, 중대형 가스터빈 엔진의 기초연구 및 가스터빈 교육용으로도 큰 의미를 가지고 있다. 현재 다수의 국내외 업체에서는 소형 가스터빈의 교육용 실험 장치를 제조 및 판매하고 있으나, 모두 운전 영역에서의 데이터 수집만이 가능하고 상용 ECU가 엔진을 제어하고 있기 때문에 소형 가스터빈의 열유체 역학적인 현상을 관측하는 것만이 가능하기 때문에 특정 목적에 따른 실험 변수의 제어를 통한 심화된 연구가 불가능하다. 따라서 본 연구에서는 사용자의 활용도가 높은 LabVIEW 소프트웨어 및 하드웨어의 신호 수집, 제어 및 분석 체계를 이용하여 소형 가스터빈의 실험 변수 제어 및 데이터 수집, 분석이 하나의 통합된 시스템 내에서 수행될 수 있는 Intefrated Modifiable Test Rig의 설계 및 제작이 수행되었다.

  • PDF