• Title/Summary/Keyword: Micro-bubble system

Search Result 62, Processing Time 0.028 seconds

Evaluation of Remediation Efficiency of In-Situ Chemical Oxidation Technology Applying Micro Bubble Ozone Oxidizer Coupled with Pneumatic Fracturing Equipment (마이크로버블 오존 산화제와 공압파쇄 장치를 연계 적용한 지중 화학적 산화법의 정화효율 평가)

  • Oh, Seung-Taek;Oh, Cham-Teut;Kim, Guk-Jin;Seok, So-Hee;Kim, Chul-Kyung;Lim, Jin-Hwan;Ryu, Jae-Bong;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.44-50
    • /
    • 2012
  • A new type of chemical oxidation technology utilizing micro bubble ozone oxidizer and a pneumatic fracturing equipment was developed to enhance field applicability of a traditional chemical oxidation technology using hydrogen peroxide as an oxidizer for in-situ soil remediation. To find an efficient way to dissolve gaseous ozone into hydrogen peroxide, ozone was injected into water as micro bubble form then dissolved ozone concentration and its duration time were measured compared to those of simple aeration of gaseous ozone. As a result, dissolved ozone concentration in water increased by 31% (1.6 ppm ${\rightarrow}$ 2.1 ppm) and elapsed time for which maximum ozone concentration decreased by half lengthened from 9 min to 33 min. When the developed pneumatic fracturing technology was applied in sandy loam, cracks were developed and grown in soil for 5~30 seconds so that the radius of influence got longer by 71% from 392 cm to 671 cm. The remediation system using the micro bubble ozone oxidizer and the pneumatic fracturing equipment for field application was made and demonstrated its remediation efficiency at petroleum contaminated site. The system showed enhanced remediation capacity than the traditional chemical oxidation technology using hydrogen peroxide with reduced remediation time by about 33%.

The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank (응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리)

  • Kim, Dong-Ha;Lee, Soo-Young;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Treatment of Hydrochloric acid from Regeneration and Scrubber system of Cold Rolling Mill Plant with Micro-bubble (마이크로버블을 이용한 냉연 산회수설비공정 발생 염화수소 가스 처리)

  • Jung, Yong-Jun;Jung, Jae-Ouk;Kim, Ye-Jin
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • This work has performed to examine the operation status of regeneration and scrubber system of cold rolling mill plant and established the DIWS(Dip Injection Wet Scrubber) system for the removal of hydrochloric acid with micro bubble. When the initial 22.3 ppm of HCl gas was injected into the system, the average exhaust HCl gas was 0.59 ppm with the removal efficiency of 97.3%. Hydrochloric acid was effectively removed by DIWS system. In the long term monitoring for 10 hours by 5 minutes through TMS(Tele Monitoring System), the average exhaust HCl gas was stably kept 0.69 ppm, which was also verified by manual measurement.

Complex Mal-odor Treatment of Foodwaste with Micro-bubble generated from Enhanced Wet Scrubber (습식세정장치에서 발생되는 마이크로버블을 이용한 음식물쓰레기 발생 복합악취 처리)

  • Kim, Ye-Jin;Jung, Jae-Ouk;Jung, Yong-Jun
    • Journal of Environmental Science International
    • /
    • v.24 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • The objective of this work was to treat complex mal-odor of food waste with micro-bubbles from enhanced wet scrubber system, where the pilot plant was operated. Micro bubbles from the enhanced reactor of venturi scrubber were successfully generated through the air atomizing process with high velocity more than 60 m/sec and played an important role in the removal of mal-odor. Mal-odor was effectively changed into the micro-bubble and treated with washing chemicals together. Through establishing two series connection of the reactors, 85.2 % removal efficiency of complex mal-odor was obtained in case of average 940 times of input air. 0.35 kg/hr of sulfuric acid, 0.188 kg/hr of sodium hydroxide and 0.043 kg/hr of hypochlorite were injected for chemical washing.

An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System (DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향)

  • Park, S.C.;Oh, H.Y.;Chung, M.K.;Song, S.L.;Ahn, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.929-936
    • /
    • 2013
  • The saturator and injection nozzle are important facilities on the dissolved air flotation process. To increase the formation of micro bubble, it is required to improve the air dissolving performance in the saturator and keep the pressure uniform from the saturator to the nozzle. This study aimed to evaluate the performance of the saturator and the hydraulic effect of the nozzle and the pipe structure. The air volume concentration, bubble size and bubble residual time were measured in the test. The saturator, which had mounted with the spray nozzle, showed a good performance for bubble formation. Also, the characteristics of micro bubble formation were influenced by pressure uniformity and flow velocity through the orifice in the nozzle.

An Experimental Study on Bubbles Growth on Microheater (마이크로 히터에서의 기포 생성에 관한 실험적 연구)

  • Ko, Seung-Hyun;Kim, Shin-Kyu;Kim, Ho-Young;Jang, Young-Soo;Lee, Yoon-Pyo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1909-1914
    • /
    • 2003
  • Bubble growth on microheater has been experimentally investigated in this study. The experiment was performed using platinum micro heaters having dimensions of $100{\times}10{\times}0.2{\mu}m^3$ with constant heat flux. A high speed video camera was used to observe bubble growth at 250 frames per second. Microheater temperature was measured at the rate of 300Hz with a data acquisition system. When heater temperature was $139^{\circ}C$ a bubble was nucleated in the liquid FC-72. The temperature profiles and the high speed camera images were combined to explain heat transfer and bubble growth on microheater.

  • PDF

Desulfurization of Biogas Using Micro Bubble in a Biogas Plant (미세버블을 이용한 바이오가스 탈황정제 연구)

  • Tak, Bong-Yul;Tak, Bong-Sik;Kim, Chan-Gyu;Min, Gil-Ho;Jang, Choon-Man
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.518-523
    • /
    • 2013
  • This paper describes the reduction of a hydrogen sulfide ($H_2S$) generated from a biogas plant. Micro bubble system is adopted to supply air into the water in the reaction chamber, which can increase the contact area of the supplied air to the reserving water. Two stage reaction chambers having two reaction rooms are designed and manufactured to enhance the reduction rate of a hydrogen sulfide. Sodium hydroxide (NaOH) is also considered to get rid of a hydrogen sulfide. Air volume rate to the water in a reaction chamber is maintained between 0.5 and $1.0m^3/min$. Throughout experimental measurement of the concentration of a hydrogen sulfide by changing the volume of supplied air into the water, reduction rate of a hydrogen sulfide increases as air volume increases. Adding sodium hydroxide to the water with the air supply can reduce effectively a hydrogen sulfide up to 99.5% from biogas. It is noted that a hydrogen sulfide generated by a biogas plant can reduce by supplying micro bubble air and sodium hydroxide effectively.

An Experimental Study on the Orifice Nozzle System that Generates Micro-bubbles by Self-suction of Air with a Recirculating Flow (재순환 유동 공기 자가흡입에 의한 마이크로버블 발생 오리피스 노즐 시스템에 대한 실험적 연구)

  • Oh, Shin-il;Park, Sang-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.82-88
    • /
    • 2018
  • An experimental study was performed on the orifice nozzle system that generates micro-bubbles by air self-suction using a venturi nozzle. This study experimentally investigates the amount of air sucked into the venturi nozzle and the number of micro-bubbles generated by the orifice nozzle system in Cases 1 and 2. The experimental conditions were varied by changing the diameter of the orifice nozzle (d=2~7 mm) and the number of holes of the perforated plate nozzle (n = 2-12). In Case 1, the air self-suction was more than 2 LPM at $d{\leq}4mm$. When d = 4 mm, the total number of bubbles was 29,777, and it was confirmed that micro-bubbles occupied approximately 65% of the total number of bubbles. In Case 2, the air self-suction was maintained constant at approximately 2.5 LPM regardless of the number (n) of holes. The total amount of bubbles increased when n increased but remained constant at approximately 44,000 when $n{\geq}7EA$. It was also confirmed that more than 80% of all bubbles were micro-bubbles when $n{\geq}10EA$. Thus, the number of micro-bubbles increased by approximately 15% compared to the experimental result of Case 1, which was optimized with d = 4 mm.

Industrial Wastewater Treatment Containing High Concentration of Ammonia with Low Energy Micro-Bubble Reactor (저에너지 마이크로버블 장치를 이용한 고농도 암모니아 공장 폐수 처리)

  • Jung, Jae-Ouk;Jung, Yong-Jun
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.286-291
    • /
    • 2016
  • This study was carried out to evaluate the feasibility of air-stripping by DIWS(Dip Injection Wet Scrubber) system on high concentration of ammonia wastewater more than 10,000 mg/L. In the case of changing temperature from $30^{\circ}C$ to $70^{\circ}C$ maintaining pH 12.5 within the 72 hours, the removal efficiency of T-N by the present treatment plant was increased to 90.5% which was initially kept 70.3%. Although the high concentration of T-N with 9,120~12,955 mg/L was treated by micro-bubble through DIWS system maintaining the temperature of $30^{\circ}C$ within the 20 hours, the removal efficiency of T-N reached 91.9%, which indicated the possibility of air-stripping.

Improvement of Medium and Small Urban Stream Water Quality and Applicability of Design Factor Using Biological and Physicochemical Processing (도심지역 내 중·소하천 수질 개선을 위한 가압부상 및 관로형 미생물 부착 공정 적용에 관한 연구)

  • Kim, Moon-Ki;Choi, Jung-Su;Kim, Sam-Ju;Kim, Hyun-Gu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.509-517
    • /
    • 2013
  • The purpose of this study is to assess the applicability of device-type stream coagulation process which combines physiochemical, biological processing for efficient improvement of water quality in small, middle-sized urban streams. The stream purification facility of this study is compose of pressure flotation type Micro Bubble Process(MBP) to remove TSS and TP and conduit line type Attached Microbial Pipe System(AMPS) to remove BOD. Test conditions of each device were set by floating stay time and change of ultra fine bubble injection amount of MBP, and change of AMPS stay time. Also, removal efficiency of pollution sources of each process were assess by change of season. As result of continuous operation of each process, MBP showed a maximum of TSS 83.69%, TP 95.15% process efficiency and AMPS showed a maximum of 52.95% TBOD5 removal efficiency. Also as result of circular operation of each process, MBP showed a maximum of TSS 69.75%, TP 70.17% process efficiency and AMPS showed a maximum of 68.58% TBOD5 removal efficiency. Therefore, it is considered that this stream coagulation process is effective in improving the water quality of streams in urban areas.