• Title/Summary/Keyword: Micro-array

Search Result 473, Processing Time 0.029 seconds

Base Station Antenna with Rectangular Radiation Pattern using Strip Feeding Planar Monopole Array (스트립 급전 평면 모노폴 배열을 이용한 직사각형 방사패턴 기지국용 안테나)

  • 신헌철;문상만;우종명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.1018-1024
    • /
    • 2001
  • In this paper, an array antenna is designed far base station of a street micro-cell in urban areas. It has a rectangular radiation pattern. The current distribution of the array is decided by using a modified Woodward-Lawson sampling pattern synthesis method. To confirm the realization of the array antenna with rectangular pattern, 12 array antenna with a planar type monopole fed by stripline is fabricated and measured. In the results of the measured values, H-plane pattern of the antenna nearly yields a rectangular radiation pattern.

  • PDF

Nanowell Array based Sensor and Its Packaging

  • Lee, JuKyung;Akira, Tsuda;Jeong, Myung Yung;Lee, Hea Yeon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • This article reviews the recent progress in nanowell array biosensors that use the label-free detection protocol, and are detected in their natural forms. These nanowell array biosensors are fabricated by nanofabrication technologies that should be useful for developing highly sensitive and selective also reproducible biosensors. Moreover, electrochemical method was selected as analysis method that has high sensitivity compared with other analysis. Finally, highly sensitive nanobiosensor was achieved by combining nanofabrication technologies and classical electrochemical method. Many examples are mentioned about the sensing performance of nanowell array biosensors will be evaluated in terms of sensitivity and detection limit compared with other micro-sized electrode without nanowell array.

Development of UV imprinting process for micro lens array of image sensor (UV 임프린트를 이용한 이미지 센서용 마이크로 렌즈 어레이 성형 공정 개발)

  • Lim, Ji-Seok;Kim, Seok-Min;Jeong, Gi-Bong;Kim, Hong-Min;Kang, Shin-Il
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.17-21
    • /
    • 2005
  • High-density image sensors have microlens array to improve photosensitivity. It is conventionally fabricated by reflow process. The reflow process has some weak points. UV imprinting process can be proposed as an alternative process to integrate microlens array on photodiodes. In this study, the UV imprionting process to integrate microlens array on image sensor was developed using W transparent flexible mold and simulated image sensor substrate. The UV transparent flexible mold was fabricated by replicating master pattern using siliconacrylate photopolymer. The releasing property and shape accuacy of siliconacrylate mold was analysed. After UV imprinting process, replication quality and align accuracy was analysed.

  • PDF

Development of Uniaxial Force Sensor Array for Tactile Sensation Using Fiber Bragg Gratings (광섬유 브래그 격자를 이용한 촉감감지용 단축 힘 센서 어레이 개발)

  • Heo, Jin-Seok;Lee, Jung-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1160-1165
    • /
    • 2006
  • In this paper, the 2-dimensional uniaxial force sensors array is introduced to detect the distributed force using fiber Bragg gratings. Uniaxial force transducer was designed to avoid the chirping and micro bending which degrade the performance of the sensor. The Brags wavelength shift of the sensor was estimated using the finite element analysis. Using this uniaxial force sensor, the uniaxial force sensors array $(3{\times}3)$ was fabricated, and the Performance of this sensors array was evaluated. The Presented sensors may has very simple configuration and its wiring is very simple compared with any other force sensors arrays.

Development of UV imprinting process for micro lens array of image sensor (UV 임프린트를 이용한 이미지 센서용 마이크로 렌즈 어레이 성형 공정 개발)

  • Lim, Ji-Seok;Kim, Seok-Min;Jeong, Gi-Bong;Kim, Hong-Min;Kang, Shin-Il
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.91-95
    • /
    • 2006
  • High-density image sensors rave microlens array to improve photosensitivity. It is conventionally fabricated by reflow process. The reflow process has some weak points. UV imprinting process can be proposed as an alternative process to integrate microlens array on photodiodes. In this study, the UV imprionting process to integrate microlens array on image sensor was developed using UV transparent flexible mold and simulated image sensor substrate. The UV transparent flexible mold was fabricated by replicating master pattern using siliconacrylate photopolymer. The releasing property and shape accuacy of siliconacrylate mold was analysed. After UV imprinting process, replication quality and align accuracy was analysed.

  • PDF

Molding of glass micro optical components (유리 마이크로 광부품 어레이의 성형)

  • 최우재;강신일
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.76-79
    • /
    • 2003
  • Glass molding is an advantageous method to manufacture glass micro optical components. However, it is difficult to make tungsten carbide core for glass molded micro optics way. We have developed novel method to fabricate tungsten carbide core for glass molding of glass micro optical components. Silicon masters were fabricated by micro machining. Tungsten Carbide cores were fabricated by forming, sintering and coating. Finally we fabricated glass molded V-groove with pitch of 192$\mu\textrm{m}$ and glass microlens way with lens diameter of 36∼225$\mu\textrm{m}$ by the present method.

  • PDF

Fluorescece Microscope using Total Internal Reflection for Measuring Biochip (내부 전반사 방식에 의한 바이오칩 측정 장비)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1694-1698
    • /
    • 2007
  • This study suggests a new fluorescence microscope to observe micro-samples within fluorophore in a variety of biomedical fields including the fluorescence analysis of a biochip, such as a DNA micro-array. A fluorescence microscope is a device for irradiating light onto a micro-object, executing an excitation and fluorescence emission process. In this study, it adopts a total internal reflection fluorescence(TIRF) method to excite a whole micro-sample substrate different from an existing way which uses an evanescent wave resulting from a total internal reflection on the micro-sample surface. Suggested TIRF microscope can reduce optical noise and obtain images with higher sensitivity thus obtain precise information about the density, quantity, location, etc. of a flurophore, and can simultaneously process separate images even when plurality of fluorophores having different excitation and fluorescent wavelength ranges is distributed, thus easily obtain information about the fluorophores.

Dynamic Characteristics Measurement of Micro Mirror for Image Display (화상처리용 마이크로 미러의 동특성 측정기술)

  • 이은호;김규로
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.371-376
    • /
    • 1997
  • A 100*100.mu.m$^{2}$ aluminum micro mirror is designed and fabricated using a thick photoresist as a sacrificial layer andas a mold for nickel electroplating. The micro mirror is composed of aluminum mirror plate, two nickel support posts, two aluminum hinges, two address eletrodes, and two landing electrodes. The aluminum mirror plate,which is supported by two nickel support posts, is overhung about 10.mu.m from the silicon substrate. THe aluminum mirror plate is actuated like a seesaw by electrostatic force generated by electic potential difference applied between the mirror plate and the address electrode. This paper presents some methods to measure the optical and the dynamic characteristics of the fabricated micro mirror.

  • PDF

Multiple-end-point Bioassays Using Microorganisms

  • Iwahashi, Hitoshi
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.400-406
    • /
    • 2000
  • Since the 1950s, the numbers of species and chemicals produced have significantly increased. Despite the fact that industrial chemicals have given us numerous benefits, there is no doubt that they have damaged the environment. The chemicals being dispersed on the earth should be carefully controlled to prevent adverse effects. Bioassay is one of the methods to assess chemical safety. In bioassay systems, chemical safety is estimated by monitoring biological responses to environmental pollutants and newly synthesized chemicals. This report introduces multiple-point bioassay systems that are based on chemical sensitivities of microorganisms, responses of one kind of organism, and micro-array technology. Multiple-end-point bioassays enable the prediction of chemicals in the environment and the understanding of toxicities of newly synthesized chemicals.

  • PDF

Cancer Genomics Object Model: An Object Model for Cancer Research Using Microarray

  • Park, Yu-Rang;Lee, Hye-Won;Cho, Sung-Bum;Kim, Ju-Han
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.29-34
    • /
    • 2005
  • DNA microarray becomes a major tool for the investigation of global gene expression in all aspects of cancer and biomedical research. DNA microarray experiment generates enormous amounts of data and they are meaningful only in the context of a detailed description of microarrays, biomaterials, and conditions under which they were generated. MicroArray Gene Expression Data (MGED) society has established microarray standard for structured management of these diverse and large amount data. MGED MAGE-OM (MicroArray Gene Expression Object Model) is an object oriented data model, which attempts to define standard objects for gene expression. To assess the relevance of DNA microarray analysis of cancer research it is required to combine clinical and genomics data. MAGE-OM, however, does not have an appropriate structure to describe clinical information of cancer. For systematic integration of gene expression and clinical data, we create a new model, Cancer Genomics Object Model.

  • PDF