• Title/Summary/Keyword: Micro-Tester

Search Result 207, Processing Time 0.022 seconds

Influence of Electrical Conductivity of Dielectric on Machinability of W-EDM (방전액의 전도율이 와이어방전가공성에 미치는 영향)

  • Kim, Chang-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.322-328
    • /
    • 2002
  • In wire-electrical discharge machining (W-EDM), the dielectric plays an important role as the working fluid. It affects the material removal rate and the properties of the machined surface. This paper deals with the effects of the electrical conductivity of dielectric and cobalt percentage of sintered carbides on the machining characteristics and the machined surface integrities with deionized water as dielectric. A series of experiments have been performed on sintered carbides having different cobalt contents. Experimental results show that a higher cobalt content of WC decreases the metal removal rate and worsens the surface quality. Lower electrical conductivity of the dielectric results in a higher metal removal rate as the gap between wire electrode and workpiece reduced. Especially, the surface integrities of rough-cut workpiece, wire electrode, and debris were analyzed also through scanning electron microscopy(SEM) and surface roughness tester. By energy dispersive spectrometry(EDS), it is confirmed that micro cracks and some of electrode material are found on the workpiece surface.

A Study on the resistance of surface hardening treated Aluminum, Titanium alloy under the high velocity impact (표면 경화 처리된 Al, Ti의 고속 충격 저항성에 관한 연구)

  • 손세원;김희재;홍성희;김영태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.852-855
    • /
    • 2002
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of surface hardening treated Aluminum, Titanium alloy laminates, ballistic tests were conducted. In this paper, Anodized Al 5083-H131 alloy laminates and nitrified Ti (Gr.2) alloy laminates were used to achieve higher surface hardness. Surface hardness test were conducted using a Micro victor's hardness tester and thickness of surface hardening treated specimens was measured by video microscope. Resistance to penetration is determined by the protection ballistic limit($V_50$), a statistical velocity with 50% probability far complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_50$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_50$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests.

  • PDF

A Study on the ELID Grinding Characteristics of SF-5 Glass and Quartz Glass for the Nano Surface Roughness (나노 표면거칠기틀 위한 SF-5유리와 수정유리의 ELID 연삭 특성에 관한 연구)

  • 곽태수;박상후;오오모리히토시;배원병;양동열
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.7
    • /
    • pp.56-62
    • /
    • 2003
  • The precision fabrication of glass is increasingly demanded for the latest industrial applications of spherical lenses, micro-optical components, and so on. In many cases, the surface roughness of glass is required to be minute for improving the optical characteristics. In this paper, machining characteristics of SF-5 glass and quarts glass are studied by using the ELID grinding process to get mirror surface and productivity compared with a general lapping process. A rotary type grinder with air spindle was used for the experiments. Mitutoyo surface tester and AFM were also used to measure the grinded surface of glass. As the results of experiments, they showed that the surface roughness (Ra) of SF-5 glass was under 7.8 nm and that of quartz glass was under 3.0 m using the # 8000 grinder. So, the possibility of highly efficient and accurate surface for optical components can be achieved by the ELID grinding process.

Wear Characteristics of Metal Ball and Seat for Metal-Seated Ball Valve (금속 볼 밸브의 볼·시트 마멸 특성에 관한 실험적 연구)

  • Bae, Junho;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.32 no.1
    • /
    • pp.32-37
    • /
    • 2016
  • The wear characteristics of metal ball and seat in a metal-seated ball valve significantly affect the performances such as leakage and valve torque. In this work, the wear characteristics of metal ball and seat are experimentally investigated. A stainless steel ball and seat with a high corrosion-resistant coating are prepared and a component level test was performed. The hardness and surface roughness of specimens cut from the metal ball and seat are measured before and after the test using a micro-Vickers hardness tester and confocal microscopy, respectively. In order to assess the wear characteristics, the surfaces of the specimens are carefully examined after the test. The confocal microscope data show that the surface roughness values of both the ball and seat increase by a factor of 3-4, which may lead to an increase in valve torque. However, the wear of the seat is found to be more significant than that of the ball. In addition, a comparison of the surfaces of the ball and seat before and after testing revealed that adhesive and abrasive wear are the major wear mechanisms. The results of this study may aid in the design of metal-seated ball valves from the tribological point of view.

The study of the fluoridation effect via individual tray compared with other methods (개인 트레이를 이용한 불소도포 효과에 관한 실험적 연구)

  • Cho, Byeng-Ken;Seo, Eun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.251-260
    • /
    • 2001
  • The purpose of this article was to compare the fluoridation effect via individual tray with other professional methods. In oder to compare the fluoridation effect, 40 extracted human teeth was divided into 4 groups(each group was composed of 10 teeth) and the surface hardness of each group was tested in untreated, after fluoridation, after fluoridation and etching by 10% lactic acids. group I: no fluoridation(control) group II : fluoridation with 123%APF group III : fluoridation by iontophoresis with 2% NaF group IV : fluoridation by individual tray with 4% SnF2 gel Surface hardness was measured with Micro hardness tester(Shimadzu Co. Japan), Data analysis was conducted using the repeated measures ANOVA test. The results were as follows: 1. Four tested groups demonstrated nearly the same SMH in extracted state. 2. The SMH after fluoridation showed $330.57{\pm}139.09kg/mm^2$ in group IV, $221.79{\pm}187.48kg/mm^2$ in group II, $186.43{\pm}53.13kg/mm^2$ in group III. So the SMH of group IV, II were was significantly increased(p<0.01). 3. The SMH of group II, III, IV after acid etching was higher than the control group(p<0.01). 4. The SMH between group II, III, and IV after acid etching was not different significantly.

  • PDF

Microstructures and Recrystallization Behavior with Heat-Treatment Conditions of Pure Zr (열처리 조건의 변화에 따른 순수 Zr의 미세조직 및 재결정 거동)

  • Lim, Yoon-Soo;Wey, Myeong-Yong;Kim, Hyun-Gil;Choi, Yang-Jin;Jeong, Yong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.4
    • /
    • pp.287-293
    • /
    • 1999
  • Effect of heat-treatment on the microstructure and recrystallization behavior of pure Zr was studied. The specimens were prepared under the various annealing temperatures from $400^{\circ}C$ to $800^{\circ}C$ and times from 300 to 5000 minutes after vacuum arc remelting. The recrystallization behavior was observed by a polarized optical microscope, TEM and micro-vickers hardness tester. With increasing the annealing time, the temperature region of hardness drop moved to the lower temperature region due to the recovery and recrystallization behaviors at the lower temperature. The recrystallization of cold-worked pure Zr was completed between 450 and $600^{\circ}C$. The size of recrystallized grain increased at $700^{\circ}C$ for 600min. Activation energy(Q) of pure Zr measured by the time for constant fraction technique was 78 KJ/mol.

  • PDF

Synthesis and Properties of a Ge2Sb2Te5 Sputtering for Use as a Target by Spark Plasma Sintering (방전 플라즈마 소결에 의한 Ge2Sb2Te5 스퍼터링 타겟 제조 및 특성)

  • Bang, C.W.;Kim, K.B.;Lee, J.K.
    • Journal of Powder Materials
    • /
    • v.21 no.2
    • /
    • pp.137-141
    • /
    • 2014
  • In this study, we report the sintering behavior and properties of a $Ge_2Sb_2Te_5$ alloy powders for use as a sputtering target by spark plasma sintering. The effect of various sintering parameters, such as pressure, temperature and time, on the density and hardness of the target has been investigated in detail. Structural characterization was performed by scanning electron microscopy and X-ray diffraction. Hardness and thermal properties were measured by differential scanning calorimetry and micro-vickers hardness tester. The density and hardness of the sintered $Ge_2Sb_2Te_5$ materials were 5.8976~6.3687 $g/cm^3$ and 32~75 Hv, respectively.

Dry sliding wear behavior of plain low carbon dual phase steel by strain hardening and oxidation (가공경화와 산화층 형성에 의한 이상조직 저탄소강의 건식 미끄럼 마멸 거동)

  • Yu, H.S.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.149-152
    • /
    • 2006
  • Dry sliding wear behavior of low carbon dual phase steel, of which microstructure consists of hard martensite in a ductile ferrite matrix, has been investigated. The wear characteristics of the dual phase steel was compared with that of a plain carbon steel which was normalized at $950^{\circ}C$ for 30min and then air-cooled. Dry sliding wear tests were carried out using a pin-on-disk type tester at various loads of 1N to 10N under a constant sliding speed condition of 0.2m/sec against an AISI 52100 bearing steel ball at room temperature. The sliding distance was fixed as 1000m for all wear tests. The wear rate was calculated by dividing the weight loss measured to the accuracy of $10^{-5}g$ by the specific gravity and sliding distance. The worn surfaces and wear debris were analyzed by SEM, EDS and a profilomter. Micro vickers hardness values of the cross section of worn surface were measured to analyze strain hardening behavior underneath the wearing surfaces. The were rate of the dual phase steel was lower than the plain carbon steel. Oxidation on the sliding surface and strain hardening were attributed for the higher wear resistance of the dual phase steel.

  • PDF

Electrical Conductivity of Dielectric on WEDM Characteristics (WEDM 가공특성에 대한 방전액의 전기전도율의 영향)

  • Kim, Chang-Ho;Yeo, Hong-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1800-1808
    • /
    • 2003
  • This work deals with the electrical conductivity of dielectric on output parameters such as metal removal rate and surface roughness value of a carbon steel(SM25C) and sintered carbides cut by wire-electrical discharge machining(W-EDM). Dielectric has several functions like insulation, ionization, cooling, the removal of waste metal particles. The presence of minute particles(gap debris) in spark gap contaminates and lowers the breakdown strength of dielectric. And it is considered that too much debris in spark gap is generally believed to be the cause of arcing. Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a lower metal removal rate because the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. Debris were analyzed also through scanning electron microscopy(SEM) and surface roughness tester. Micro cracks and some of electrode material are found on the workpiece surface by energy dispersive spectrometer(EDS).

The properties of diamond-like carbon(DLC) films prepared using ECR-PECVD and its dependence on deposition parameers

  • 손영호;박노길;박형국;정재인;김기홍;배인호;김인수;황도원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.47-47
    • /
    • 1999
  • 2.45 GHz 마이크로웨이브를 이용하는 electron cyclotron resonance plasma enhanced chemical vapor deposition(ECR-PECVD)방법으로 다이아몬드성 탄소박막(diamond-like carbon, DLC)을 증착하였다. DLC 박막의 산업 응용을 위해서는 높은 경도와 밀착력이 필요하다. 그래서 본 실험에서는 DLC 박막의 산업 응용을 위하여 ECR-PECVD 방법으로 증착된 DLC 박막의 분석결과로부터 DLC 박막의 물성과 증착조건의 관계를 조사하였다. 기판으로는 실리콘 웨이퍼와 실험용 SUS 판을 사용하였다. 아르곤 가스를 주입하여 ECR 마이크로 웨이브 플라즈마와 negative DC bias로 기판을 플라즈마 세척한 후, 수소와 메탄가스를 반응기체로 하여 DLC 박막을 증착하였다. 박막 증착시에 13.56MHz RF 전원 공급장치로 기판에 전원을 공급하였다. DLC 박막 증착의 변수는 반응기체의 호합율, 마이크로웨이브 파워, 프로세스 압력 및 RF 전원공급장치에서 유도되는 negative self DC bias 등이다. 이때 사용된 반응기체의 혼합율(메탄/수소)은 10~50%이고, 수소 가스 흐름율은 100sccm, 메탄은 10~50sccm이다. 마이크로웨이브의 크기는 360~900W, negative self DC bias는 -500~-10 V였다. 그리고 본 실험에서는 높은 증착율을 고려하여 프로세스 압력을 10~30mTorr까지 조절하였다. ER-PECVD 방법으로 증착된 DLC 박막은 SEM으로 단면, $\alpha$-Step으로 두께, Raman 분광계로 탄소 결합구조, FTIR 분광계로 탄소와 수소 결합구조, Micro-Hardness로 경도 그리고 Scratch Tester로 밀착력 등을 분석하였다.

  • PDF