• 제목/요약/키워드: Micro porous layer(MPL)

검색결과 11건 처리시간 0.026초

미세다공층의 침투깊이가 다른 기체확산층이 고분자전해질 연료전지의 성능과 내구성에 미치는 영향에 관한 연구 (Study on Performance and Durability of the Proton Exchange Membrane Fuel Cell with Different Micro Porous Layer Penetration Thickness)

  • 조준현;박재만;오환영;민경덕;정지영;이은숙
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.81.2-81.2
    • /
    • 2011
  • The gas diffusion layer (GDL) consists of two main parts, the GDL backing layer, called as a substrate and the micro porous layer (MPL) coated on the GDBL. In this process, carbon particles of MPL penetrates to the GDBL consequently forms MPL penetration part. In this study, the micro porous layer (MPL) penetration thickness is determined as a design parameter of the GDL which affect pore size distribution profile through the GDL inducing different mass transfer characteristics. The pore size distribution and water permeability characteristics of the GDL are investigated and the cell performance is evaluated under fully/low humidification conditions. Transient response and voltage instability are also studied. In addition, to determine the effects of MPL penetration on the degradation, the carbon corrosion stress test is conducted. The GDL that have deep MPL penetration thickness shows better performance in high current density region because of enhanced water management, however, loss of penetrated MPL parts is shown after aging and it induces worse water management characteristics.

  • PDF

열처리 슬러리코팅법을 이용한 연료전지 가스확산층의 제조 (Fabrication of Gas Diffusion Layer for Fuel Cells Using Heat treatment Slurry Coating Method)

  • 김성진;박성범;박용일
    • 열처리공학회지
    • /
    • 제25권2호
    • /
    • pp.65-73
    • /
    • 2012
  • The Gas Diffusion Layer (GDL) of fuel cell, are required to provide both delivery of reactant gases to the catalyst layer and removal of water in either vapor or liquid form in typical PEMFCs. In this study, the fabrication of GDL containing Micro Porous Layer (MPL) made of the slurry of PVDF mixed with carbon black is investigated in detail. Physical properties of GDL containing MPL, such as electrical resistance, gas permeability and microstructure were examined, and the performance of the cell using developed GDL with MPL was evaluated. The results show that MPL with PVDF binder demonstrated uniformly distributed microstructure without large cracks and pores, which resulted in better electrical conductivity. The fuel cell performance test demonstrates that the developed GDL with MPL has a great potential due to enhanced mass transport property due to its porous structure and small pore size.

인산형 연료전지(PAFC)의 전극 성능 향상을 위한 미세다공층(MPL)의 적용 (Application of Micro Porous Layer (MPL) for Enhance of Electrode Performance in Phosphoric Acid Fuel Cells (PAFCs))

  • 하지훈;강성민;오유관;백동현
    • 전기화학회지
    • /
    • 제27권1호
    • /
    • pp.32-39
    • /
    • 2024
  • 인산형 연료전지(PAFC)의 전기화학적 성능에 영향을 미치는 핵심 부품은 전극 촉매, 전해질 매트릭스 및 기체확산층(GDL) 등이 있다. 또한 전극의 성능 향상을 위해 GDL 위에 미세다공층(MPL)을 적용하는 방법도 있다. MPL은 주로 고분자 전해질 연료전지(PEMFC)에서 전극 내부의 수분 관리와 접촉 저항 저감을 위한 중간 완화층 역할을 한다. 본 연구에서는 MPL이 PAFC 전극의 성능에 미치는 영향을 확인하기 위해 MPL이 없는 GDL과 MPL을 적용한 GDL로 전극을 제작하여 단위전지의 내부 저항과 분극 곡선을 서로 비교하였다. 본 실험 결과에서 MPL을 적용하였을 때 전극의 출력 밀도가 170.2 mW/cm2에서 192.1 mW/cm2으로 향상되었다. MPL은 PEMFC에서와 같이 PAFC 전극에서도 매트릭스와 전극에서 액체 전해질과 물 관리에 효과적으로 작용하고 전극 내부의 물질 전달이 향상되어 전극 성능이 향상된 것으로 판단된다. 또한, MPL의 적용으로 PAFC 전극의 내부 저항이 감소하였고 장기 운전시에도 안정적인 성능을 지속적으로 유지하는 결과로부터 PAFC 전극에도 MPL을 적용하면 전극 성능을 향상시킬 수 있음을 확인할 수 있었다.

고분자전해질 연료전지에서 다양한 기체확산층의 물리적 특성과 연료전지 성능 비교 (Comparison of Cell Performance with Physical Properties of Gas Diffusion Layers in PEMFCs)

  • 이지정;김인태;장언;이홍기;심중표
    • 전기화학회지
    • /
    • 제10권4호
    • /
    • pp.270-278
    • /
    • 2007
  • 다양한 종류의 기체확산층 (gas diffusion layer, GDL)을 이용하여 고분자전해질 연료전지의 성능을 시험하였으며 이를 통해 GDL의 물리적 특성과 연료전지의 성능과의 상관관계를 규명하고자 하였다. 전기전도도, 기공도, air permeability, water flux, PTFE 함량, micro-porous layer (MPL)의 유무에 따른 연료전지 성능의 변화가 고찰되었다. GDL의 물리적 특성들은 서로 밀접한 관계를 가지고 있어 연료전지의 성능변화에 영향을 주었다. Carbon paper나 carbon cloth상에 MPL의 형성이 GDL의 물리적 특성을 변화시켜 연료전지의 성능을 변화시킬 수 있음을 관찰하였다. 물리적 특성과 연료전지 성능과의 관계는 전류밀도의 크기에 따라 다른 경향을 나타내거나 혹은 무관한 경향을 보였다.

수전해·연료전지 가역셀에서 이중 가스 확산층의 효과 (Effect of Double Porous Layer on a Polymer Electrolyte Unitized Regenerative Fuel Cell)

  • 황철민;박대흠;정영관;김경훈;김종수
    • 한국수소및신에너지학회논문집
    • /
    • 제24권4호
    • /
    • pp.320-325
    • /
    • 2013
  • TUnitized reversible fuel cells (URFC) combine the functionality of a fuel cell and electrolyzer in one unitized device. For a URFC with proton exchange membrane, a titanium (Ti)-felt is applied to the gas diffusion layer (GDL) substrate at the oxygen electrode, and additionally titanium (Ti)-powders and TiN-powders are loaded in the GDL substrate as a micro porous layer (MPL). Double porous layer with TiN MPL was not acceptable for the URFC because both of fuel cell performance and electrolysis performance are degraded. The double porous layer with Ti-powder loading in the Ti-felt substrate influence rearly for the electrolysis performance. In contrast, the change of pore-size distribution brings a significant improvement of fuel cell performance under fully humidification conditions. This fact indicates that the hydrophobic meso-pores in the GDL play an important role for mass transport.

기체확산층의 미세다공층 침투 깊이에 따른 고분자 전해질형 연료전지의 내구성능 저하 분석에 관한 연구 (Study on the Durability Characteristics of the PEM Fuel Cells having Gas Diffusion Layer with Different Micro Porous Layer Penetration Thicknesses)

  • 박재만;오환영;조준현;민경덕;이은숙;정지영
    • 한국수소및신에너지학회논문집
    • /
    • 제24권3호
    • /
    • pp.216-222
    • /
    • 2013
  • Durability characteristics of Gas Diffusion Layer(GDL) is one of the important issues for accomplishing commercialization of Proton Exchange Membrane Fuel Cell(PEMFC). It is strongly related to the performances of PEMFC because one of the main functions of GDL is to work as a path of fuel, air and water. When the GDL does not work on their proposed functions due to the degradation of durability, mass transfer in PEMFC is disturbed and it might cause the flooding phenomenon. Thus, investigating the durability of GDL is important and understanding the GDL degradation process is needed. In this study, electrochemical degradation with carbon corrosion is introduced. The carbon corrosion experiment is carried out with GDLs which have different MPL penetration thicknesses. After the experiment, the amount of degradation of GDL is measured with various properties of GDL such as weight, thickness and performance of the PEMFC. The degraded GDL shows loss of their properties.

Investigation of Water Transport in Newly Developed Micro Porous Layers for Polymer Electrolyte Membrane Fuel Cells

  • Alrwashdeh, Saad S.;Markotter, Henning;Haussmann, Jan;Hilger, Andre;Klages, Merle;Muller, Bernd R.;Kupsch, Andreas;Riesemeier, Heinrich;Scholta, Joachim;Manke, Ingo
    • Applied Microscopy
    • /
    • 제47권3호
    • /
    • pp.101-104
    • /
    • 2017
  • In this investigation, synchrotron X-ray imaging was used to investigate the water distribution inside newly developed gas diffusion media in polymer electrolyte membrane fuel cells. In-situ radiography was used to reveal the relationship between the structure of the microporous layer (MPL) and the water flow in a newly developed MPL equipped with randomly arranged holes. A strong influence of these holes on the overall water transport was found. This contribution provides a brief overview to some of our recent activities on this research field.

고온 고분자 전해질막 연료전지 수소극 전극에서 서로 다른 가스 확산층에 따른 최적 바인더 함량 결정 (Determination of Optimum Binder Content in the Catalyst Layer with Different GDL for Anode of HT-PEMFC)

  • 전현수;김도형;정현승;박찬호
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.38-46
    • /
    • 2022
  • Two different gas diffusion layers having noticeable differences in micro-porous layer's (MPL's) crack were studied as a substrate for the gas diffusion electrode (GDE) with different binder/carbon (B/C) ratios in high-temperature polymer electrolyte fuel cell (Ht-PEMFC). As a result, the performance defined as the voltage at 0.2 A/cm2 and maximum power density from the single cells using GDEs from H23 C2 and SGL38 BC with different B/C ratios were compared. GDEs from H23 C2 showed a proportional increase of the voltage with the binder content on the other hand GDEs from SGL38 BC displayed a proportional decline of the voltage to the binder content. It was revealed that MPL crack influences the structure of catalyst layer in GDEs as well as affects the RCathode which is in close connection with the Ht-PEMFC performance.

건조조건 변화에 따른 미세기공층 내의 기공분포 변화가 고분자 전해질 연료전지 성능에 미치는 영향 (Effect of pore size distribution in micro porous layer using pore forming agents under various dying conditions on PEMFC performance)

  • 전정환;조동현;박기태;김성현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.71.1-71.1
    • /
    • 2010
  • 고분자 전해질 연료전지(PEMFC) 내의 기체확산층(GDL)은 셀 내의 물 관리에 중요한 역할을 수행한다. 일반적으로 다공성 기제(GDBL) 위에 미세기공층(MPL)을 코팅한 2층 구조의 기체확산층이 사용되는데, 이 미세기공층은 카본파우더와 테프론의 혼합물로 이루어져 있으며 촉매층에서 발생한 물을 셀 밖으로 빠르게 배출하는 역할을 수행한다. 본 연구에서는 다양한 기공분포를 갖는 미세기공층을 제조하여 고분자 전해질 연료전지 성능에 미치는 영향을 분석하였다. 미세기공층 슬러리내에 암모늄염 계열의 기공형성제를 혼합하여 다공성 기제 위에 코팅한 후 다양한 온도조건에서 건조함에 따라 기공분포가 다른 미세기공층을 제조하였다. 이렇게 제조된 미세기공층의 물성은 수은기공도계, FE-SEM, 자체적으로 제조한 기체투과도 측정 장치를 사용하여 측정하였으며, 단위 전지 성능 측정은 두 개의 가습조건(RH100%, RH50%)에서 실시하였다. 기공분포 측정결과 건조온도가 높은 미세기공층은 건조온도가 낮은 미세기공층에 비해 직경이 1,000 - 20,000 nm 인 대공극(macropore)의 수가 많지만, 직경이 100 nm 이하의 미세공 (micropore)의 수가 적은 것을 확인하였다. 전지성능 측정 결과 고가습 조건 (RH100%)에서는 미세공 (micropore)이 발달한 미세기공층을 포함한 기체확산층을 사용한 경우 가장 우수한 성능을 보여고, 저가습 조건 (RH50%)에서는 대공극 (macropore)이 발달한 미세기공층을 포함한 기체확산층을 사용한 경우 가장 우수한 성능을 나타내었다. 이는 물배출에 유리한 미세공 (micropore)의 성질과 원료 기체의 이동에 유리한 대공극(macropore)의 성질에 의한 것으로 판단된다. 따라서 셀 운전 가습조건에 따라 최적화된 기공구조를 갖는 미세기공층을 사용함으로써 셀 운전 성능을 향상 시킬 수 있을 것으로 예상된다.

  • PDF

고분자전해질형연료전지의 가스 채널 최적화를 위한수치적연구(I) -가스 채널 치수가 전류밀도와 HFR 분포에 미치는영향성- (Numerical Study of Land/Channel Flow-field Optimization in Polymer Electrolyte Fuel Cells (PEFCs) (I) -The Effects of Land/Channel Flow-field on Current Density and HFR Distributions-)

  • 주현철
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.683-694
    • /
    • 2008
  • The performance and durability of Polymer Electrolyte Fuel Cells (PEFCs) are strongly influenced by the uniformity of current density, temperature, species distributions inside a cell In order to obtain uniform distributions in them, the optimal design of flowfield must be a key factor. In this paper, the numerical study of land/channel flowfield optimizations is performed, using a multi-dimensional, multi-phase, non-isothermal PEFC model. Numerical simulations reveal more uniform current density and HFR(High Frequency Resistance) distributions and thus better PEFC performance with narrower land/channel width where the less severe oxygen depletion effect near the land region and more uniform contact resistance variation along the in-plane direction are achieved. The present study elucidates detailed effects of land/channel width and assist in identifying optimal flow-field design strategies for the operation of PEFCs.