• 제목/요약/키워드: Micro part

검색결과 682건 처리시간 0.025초

ER유체를 이용만 마이크로 폴리싱 특성 (Characteristics of Micro-polishing using the Electro-rheological Fluid)

  • 이재종;이응숙;황경현;민승기
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.38-42
    • /
    • 2002
  • In the recent, electro-rheological fluid has been used for micro polishing of the 3-dimensional micro-aspherical lens and some sectional parts with defects on the wide flat wafer. The ER fluid has the properties that its viscosity has drastic changed under some electric fields. Therefore, ER fluid can be applicable to the micro polishing fur some parts using these properties. In this paper, the experimental device has been constructed using the precision milling machine in order to micro polishing far some sectional parts of a 4 inches wafer It is consisted of a small steel electrode, a wafer fixture, DC10mA and 5KV power supply unit, and a controller unit. Using the ER experimental device, possibility of amending for wide flat wafer and micro polishing of some micro part has been analyzed.

  • PDF

$50{\mu}m$ Microlens 패턴 금형의 미세사출성형 전사성과 전광특성 기초연구 (A Basic Study of replication and brightness for micro injection molding with ${\sim}50{\mu}m$ micro-lens pattern mold)

  • 황철진;고영배;허영무
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.280-283
    • /
    • 2004
  • Micro-lens patterned micro-mold fabrication method for Light Guiding Plate(LGP), kernel part of LCD-BLU(Back Light Unit), was presented. Instead of erosion dot pattern for LGP optical design, micro-lens pattern, fabricated by LIGA-reflow process, was applied. Optical pattern design method was also developed not only for negative pattern LGP, but also positive pattern LGP. During injection molding process, experimental study was conducted to improve replication quality and brightness of ${\sim}50um$ micro-lens pattern mold. The effect of mold temperature for the replication quality of micro-lens array was studied.

  • PDF

마이크로 채널 충전 과정의 유동 현상 (II) - 수치 해석 - (Flow Phenomena in Micro-channel Filling Process (II) - Numerical Analysis -)

  • 김동성;이광철;권태헌;이승섭
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.657-665
    • /
    • 2003
  • Several interesting results were obtained from the flow visualization experiment in the accompanying paper, Part I. in the present study, Part II, a numerical study has been carried out to explain the detailed flow phenomena in micro-channel filling process. Hele-Shaw flow approximation was applied to the micro-channel geometry based on the small characteristic length. And surface tension effect has been introduced on the flow front as the boundary condition with the help of a dynamic contact angle concept between the melt front and the wall. A dimensional analysis for numerical results was carried out and a strong relationship between dimensionless pressure and Capillary number is obtained. The numerical analysis results are compared with the flow visualization experimental observations. And the numerical system developed in the present study seems to be able to predict the interesting micro-channel filling flow characteristics observed from experiments.

준 능동형 로터를 이용한 마이크로 혼합기의 제작 및 혼합특성 (Fabrication and Mixing Characteristics of a Micro-Mixer with a Quasi-Active Rotor)

  • 김용대;이종광;권세진
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.417-424
    • /
    • 2009
  • A micro-mixer with a quasi-active rotor was fabricated, and mixing characteristics were evaluated. The proposed micro-mixer combines an active type micro-mixer with a passive type micro-mixer. The micro-rotor, which is a moving part of an active type micro-mixer, is added in a micro-chamber of a passive type vortex micro-mixer. The rotor rotated by inflows tangent to a chamber, causing strong perturbations. The micro-mixers were fabricated using photosensitive glass. Mixing efficiency of the micro-mixers was measured using an image analysis method. Mixing efficiency and characteristics of the micro-rotor mixer were compared with the vortex micro-mixer without a rotor. Mixing efficiency was reduced as Reynolds number increased at a low Reynolds number due to decrease of residence time. Mixing efficiency at higher Reynolds number, on the other hand, was improved even though residence time decreased since the contact surface between fluids increased by twisted flow. The perturbation induced by rotating rotor at greater than Re 200 improved the efficiency of the rotor mixer.

점 전극을 이용한 마이크로 전해가공 기구에 관한 연구 (A Study on the Mechanism of Micro-ECM by Use of Point Electrode Method)

  • 김봉규;전종업;박규열
    • 한국정밀공학회지
    • /
    • 제19권8호
    • /
    • pp.77-83
    • /
    • 2002
  • This research aimed at from the establishment of theory on micro electrochemical machining mechanism to the implementation of a practical fabrication system of micro parts. In detail, the mechanism of micro-ECM was investigated with potentiodynamic method and the optimal condition for micro-ECM was selected by voltage-current-time curve with potentiostatic method. From the experimental result, the micro part which has extremely fine surface could be fabricated by use of micro-ECM with point electrode method.

바이오용 마이크로 핀의 제작에 관한 연구 (A study on Manufacturing of Micro Dotting Pin)

  • 이영수;김광순;김병희
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.21-27
    • /
    • 2003
  • The bio-micro pin is usually used for biochemistry analysis. The capability of manufacturing the micro-pin and array with effective and low-cost way is very important to developers. The micro-pin is composed of "sample channel" putting liquid into already fixed volume, "flat tip" having connection with printing quantity, and "head part" for preventing it from rotation of pin in the holder. We analyzed out printing variation in accordance with shape and tip size of the micro-pin point channel, In this study, we suggested the manufacturing progress and shape demand condition of the micro-pin which could put $0.2{\mu}{\ell}$-biochemistry material into the sample volume, and will be able to produce the micro-pin which can put $10n{\ell}$-biochemistry material into the sample volume in the future.

  • PDF

마이크로 가스터빈 시험 장치 개발 (Development of Test Facility for Micro Gas Turbine)

  • 임형수;최범석;박무룡;황순찬;박준영;서정민;방제성;임영철;오인균;김병옥;조주형
    • 한국유체기계학회 논문집
    • /
    • 제18권5호
    • /
    • pp.42-48
    • /
    • 2015
  • To improve the core technology of the micro gas turbine, the performance test facility was developed. This paper is focusing on the explanation of the characteristics of micro gas turbine and its assist devices. Major part of micro gas turbine were radial type of compressor, annular type of combustor, radial type of turbine, thrust foil bearing, radial foil bearing and generator. The assist devices were consist of exhaust duct, inverter, data acquisition system, load bank and test cell. Before building up the test facility, the component test was previously conducted to confirm the component performance. After the test facility was prepared, the motoring test was conducted to investigate the rotor dynamic characteristics of the micro gas turbine. Also, the part load performance test was performed. With a developed micro gas turbine test facility, the improved core technology about the micro gas turbine can be suggested to the related industries.

마이크로 체결부품 전조성형공정에 관한 해석 및 실험적 고찰(Part I: 유한요소 해석기반 공정변수 영향분석) (Analysis and Experiments on the Thread Rolling Process for Micro-Sized Screws Part I: Process Parameter Analysis by Finite-Element Simulation)

  • 송정한;이종섭;이혜진;이근안;박기동;나승우;이형욱
    • 소성∙가공
    • /
    • 제20권8호
    • /
    • pp.581-587
    • /
    • 2011
  • The production of high-precision micro-sized screws, used to fasten parts of micro devices, generally utilizes a cold thread-rolling process and two flat dies to create the teeth. The process is fairly complex, involving parameters such as die shape, die alignment, and other process variables. Thus, up-front finite-element(FE) simulation is often used in the system design procedure. The final goal of this paper is to produce high-precision screw with a diameter of $800{\mu}m$ and a thread pitch of $200{\mu}m$ (M0.8${\times}$P0.2) by a cold thread rolling process. Part I is a first-stage effort, in which FE simulation is used to establish process parameters for thread rolling to produce micro-sized screws with M1.4${\times}$P0.3, which is larger than the ultimate target screw. The material hardening model was first determined through mechanical testing. Numerical simulations were then performed to find the effects of such process parameters as friction between work piece and dies, alignment between dies and material. The final shape and dimensions predicted by simulation were compared with experimental observation.

LIGA-reflow 응용 Micro-lens Pattern 도광판 금형 제작 (Micro-lens Patterned LGP Injection Mold Fabrication by LIGA-reflow Process)

  • 황철진;김종덕;정재완;하수용;이규현
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.241-244
    • /
    • 2004
  • Microlens patterned micro-mold fabrication method for Light Guiding Plate(LGP), kernel part of LCD-BLU(Back Light Unit), was presented. Instead of erosion dot pattern for LCP optical design, microlens pattern, fabricated by LIGA-reflow process, was applied. Optical pattern design method was also developed not only for negative pattern LGP, but also positive pattern LGP. In order to achieve flow balance during the micro-injection molding process and dimensional accuracy, two LGP pattern was made in one micro-mold.

  • PDF

미세채널 구조물 상부의 초정밀 연마 기술 연구 (A Study on the Ultra-Precision Polishing Technique for the Upper Surface of the Micro-Channel Structure)

  • 강정일;이윤호;안병운;윤종학
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.313-317
    • /
    • 2003
  • Micro-Channel ultra-precision polishing is a new technology used in magnetic field-assisted relishing. In this paper, an electromagnet or the i18 of test system was designed and manufactured. A size of magnetic abrasive is used on 25~75${\mu}{\textrm}{m}$ and for the polish a micro-channel upper part. A surface of channel which is not even is manufactured using magnetic abrasive finishing at upper surface of micro-channel. As a result, the surface roughness rose by 80% after upper surface of micro- channel was polished up 8 minutes by polishing.

  • PDF