• Title/Summary/Keyword: Micro element

Search Result 816, Processing Time 0.028 seconds

Comparison of Homogenization Techniques in Magnetostatic Field Problems (정자장 문제의 균질화 기법의 비교)

  • Choi, Jae-Seok;Yoo, Jeong-Hoon;Nishiwaki, Shinji;Terada, Kenjiro
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.388-394
    • /
    • 2007
  • Many engineering problems require the calculation of effective material properties of a structure which is composed of repeated micro-structures. The homogenization method has been used to calculate the effective (homogenized) properties of composites and several homogenization procedures for different physical fields have been introduced. This research describes the modified homogenization technique for magnetostatic problems. Assuming that the material is periodically repeated, its effective permeability can be prescribed by calculating the homogenized magnetic reluctivity using the finite element analysis of the micro unit cell. Validity of the suggested method is confirmed by comparing the results by the energy based method as well as the widely known homogenization method.

Effects of trabecular bone microstructure on stress distribution within premolar tooth and implant (망상골의 구조와 밀도가 치과용 임플란트와 하악골에 미치는 영향)

  • Chon Chang Soo;Lee Sang Up;Lee Kyoung Joung;Kim Han Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.210-217
    • /
    • 2005
  • This study examined the effect of cancellous bone microstructure on stress distribution within a premolar tooth and a dental implant against mastication force by the micro-finite element method (FEM). The mandibular specimen including a premolar was obtained from a cadaver and scanned with micro-CT to obtain CT images. FE models were reconstructed from CT images at mid-sagittal plane of the tooth. Six models were generated and analyzed for different structure and density in cancellous bone. Stress distributions fur each implant (or tooth) and the surrounding bone were compared. The study indicated that the microstructure of cancellous bone should be considered in finite element analysis to produce reasonable results and thus implant systems with high success rate.

Thermal Fatigue Life Prediction of ${\mu}BGA$ Solder Joint Using Sn-37mass%Pb Solder and Sn-3.5mass%Ag Lead-free Solder (Sn-37mass%Pb 솔더 및 Sn-3.5mass%Ag 무연솔더를 이용한 ${\mu}BGA$ 솔더접합부의 열피로수명 예측)

  • 신영의;이준환;하범용;정승부;정재필
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.406-412
    • /
    • 2001
  • This study is focussed on the numerical prediction of the thermal fatigue life of a ${\mu}BGA$(Micro Ball Grid Array) solder joint. Numerical method is used to perform three-dimensional finite element analysis for Sn-37mass%Pb. Sn-3.5mass%Ag solder alloys during the given thermal cycling. Strain values, along with the result of mechanical fatigue tests for solder alloys were then used to predict the solder joint fatigue life using the Coffin-Manson equation. In this study, a practical correlation for the prediction of the thermal fatigue life is suggested by using the dimensionless variable $\gamma$. As a result. it could be found that Sn-3.5mass%Ag has longer fatigue life than Sn-37mass%Pb in low cycle fatigue. In addition. the result with ${\gamm}ashow$a good agreement with the FEA results.

  • PDF

Micro-mechanical FE Analysis of Dual-phase Steels (미세조직이 고려된 이상 조직강의 유한 요소 해석)

  • Ha, J.;Lee, J.W.;Kim, J.H.;Barlat, F.;Lee, M.G.
    • Transactions of Materials Processing
    • /
    • v.24 no.3
    • /
    • pp.194-198
    • /
    • 2015
  • Microstructure based FE simulations were conducted to investigate the micro-mechanical properties of ferrite-martensite dual-phase steels. The FE model was built based on real microstructure images which were characterized by optical microscopy through the thickness direction. Serial sectioned 2D images were converted into semi-2D representative volume elements (RVEs) model. Each RVE model was subjected to a non-proportional loading condition and the mechanical response was analyzed on both the macroscopic and microscopic levels. Macroscopically, stress-strain curves were described under tension-compression and tension-orthogonal tension conditions and the Bauschinger effect was well captured for both loading paths. In addition, micromechanical properties were investigated in the view of stress-strain partitioning and strain localization during monotonic tension.

Thermo-Mechanical Behavior of Type 304 Stainless Slab in Hot Charge Rolling Condition (스테인리스 304 슬라브의 HCR 조건시 열적/기계적 거동)

  • C.G. Sun;S.M. Hwang
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.183-186
    • /
    • 2003
  • A finite element-based, integrated process model is presented for a three dimensional, coupled analysis of the thermal and mechanical behavior of type 304 stainless slab during hot charge rolling (HCR) and cold charge rolling (CCR) processes. The validity of the proposed model is examined through comparison with measurements. The susceptibility on micro-crack initiation or propagation due to the thermal stress in these two different process conditions was examined. The model's capability of revealing the effect of diverse process parameters is demonstrated through a series of process simulation.

  • PDF

Characteristics of poly 3C-SiC doubkly clamped beam micro resonators (양단이 고정된 빔형 다결정 3C-SiC 마이크로 공진기의 특성)

  • Ryu, Kyeong-Il;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.217-217
    • /
    • 2009
  • This paper describes the characteristics of polycrystalline 3C-SiC doubly clamped beam micro resonators. The polycrystalline 3C-SiC doubly clamped beam resonators with 60 ~ 100 ${\mu}m$ lengths, $10\;{\mu}m$ width, and $0.4\;{\mu}m$ thickness were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonant frequency was measured by a laser vibrometer in vacuum at room temperature. For the 60 ~ 100 ${\mu}m$ long cantilevers, the fundamental frequency appeared at 373.4 ~ 908.1 kHz. The resonant frequencies of doubly clamped beam with lengths were higher than simulated results because of tensile stress. Therefore, polycrystalline 3C-SiC doubly clamped beam micro resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

  • PDF

Micro Valve with Functional Actuator (기능성 액츄에이터를 이용한 마이크로 밸브)

  • Yun, So-Nam;Ham, Young-Bog;Lee, Kyung-Woo;Kanda, Kunio
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.951-955
    • /
    • 2004
  • Piezoelectric(PZT) actuator can substitute for solenoid which is used in fluid control field because it has faster response times and no possibility of explosion. Besides, it is available in a high temperature and it has low energy consumption. In this study, pneumatic micro valve, bimorph type PZT actuator using the softner type PZT, carbon plate as a shim and its controller circuit were suggested and investigated. Performance tests and characteristics analysis, such as displacement, force, hysteresis and frequency properties, were carried out. The displacement of the actuator measured at the end point was 63 ${\mu}m$., force of the actuator was 0.052 N and maximum operating frequency was 15Hz. Also, characteristics of the micro valve with PZT actuator were evaluated in a testing system. The results show that the suggested PZT actuator is suitable for micro valve.

  • PDF

The Effects of Stress Fields on Behavior of Primary Cracks Initiated at Micro Surface Defects (미소 표면 결함에서 발생하는 초기 균열의 거동에 미치는 응력장의 영향)

  • 김진봉;김만근
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.25-32
    • /
    • 1999
  • This study has been performed to investigate the stress distribution around defects that behave as stress concentrators. Besides, the effect of stress interaction effects on the initiation of primary cracks were also investigated by rotary bending fatigue tests which were performed with specimens drilled micro surface defects and the stress distribution was analyzed using Finite Element Method. In addition, the stress interaction effects around defects and cracks were investigated by comparing the results of experiments and F.E.M. The results obtained are summarized as follows ; 1) Area which slip and micro cracks initiated at micro surface defects is between the maximum shear stress points and this area is over than ${\pm}30^{\circ}$ from the maximum stress point along the defect edge. 2) The stress interaction effect for the small size defect is larger than that of large size defect when the interval between them is near 3) Interval which there is no shear stress interaction effect analyzed by F.E.M. is larger than that of experimental results.

  • PDF

Contact Stress Analysis of Shrink-fitted Specimen considering Micro-slip (미소슬립을 고려한 압입 시편의 접촉응력 해석)

  • Lee Dong-hyong;Goo Byeong-choon;Lee Chan-woo;Jung Heung-che
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.632-637
    • /
    • 2004
  • In the shrink or press fitted shaft such as railway axle, fretting can occur by cyclic stress and micro-slippage due to local movement between the shaft and the hub. When the fretting occurs in the press fitted shaft, the fatigue strength remarkably decreases compared with that of without fretting. In this paper, the analysis of contact stresses in a press fitted shaft in contact with a hub was conducted by finite element method and the micro-slip according to the bending load was analyzed. It is found that the largest stress concentration and maximum slip amplitude of shrink fitted shaft are found at the edge of the interface and the distribution of contact stresses at the contact edge has largely influenced and coefficient of friction.

  • PDF

Fabrication of Polycrystalline SiC Doubly Clamped Beam Micro Resonators and Their Characteristics (양단이 고정된 빔형 다결정 3C-SiC 마이크로 공진기의 제작과 그 특성)

  • Chung, Gwiy-Sang;Lee, Tae-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.4
    • /
    • pp.303-306
    • /
    • 2009
  • This paper describes the characteristics of polycrystalline 3C-SiC doubly clamped beam micro resonators. The polycrystalline 3C-SiC doubly clamped beam resonators with $60{\sim}100{\mu}m$ lengths, $10{\mu}m$ width, and $0.4{\mu}m$ thickness were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonant frequency was measured by a laser vibrometer in vacuum at room temperature. For the $60{\sim}100{\mu}m$ long cantilevers, the fundamental frequency appeared at $373.4{\sim}908.1\;kHz$. The resonant frequencies of doubly clamped beam with lengths were higher than simulated results because of tensile stress. Therefore, polycrystalline 3C-SiC doubly clamped beam micro resonators are suitable for RF MEMS devices and bio/chemical sensor applications.