• Title/Summary/Keyword: Micro channel tube

Search Result 34, Processing Time 0.035 seconds

Measurements of Plasma Flows in Micro-Tube/Channel Using Micro-PIV (Micro-PIV를 이용한 마이크로 튜브/채널 내에서의 혈장유동 측정)

  • Ko Choon Sik;Yoon Sang Youl;Ji Ho Seong;Kim Jae Min;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.87-90
    • /
    • 2003
  • In this paper, flow characteristics of plasma flow in a micro-tube were investigated experimentally using Micro-PIV. For comparision, the experiments were repeated for DI-water instead of plasma. Both velocity profiles of Plasma and DI-water are well agreed with the theoretical velocity distribution of newtonian fluid. We also carried out generating plasma-in-oil droplet formation at a Y-junction microchannel. In order to clarify the hydrodynamic aspects involved in plasma droplet formation. Rhodamin B were mixed with plasma only for visualization of plasma droplet.

  • PDF

Thermal and Flow Analysis of the Flat Tube with Micro-Channels (미세유로를 갖는 납작관의 열·유동 해석)

  • Chung, Kilyoan;Lee, Kwan-Soo;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.978-986
    • /
    • 1999
  • In this study, the general thermal and flow characteristics of flat tube with micro-channels has been studied and the correlation of Nusselt number and friction factor is proposed. The optimal flat tube geometry is determined by optimal design process. It is assumed to be a three dimensional laminar flow in the analysis of thermal and flow characteristics. The periodic boundary condition is applied since the geometry of flat tube with micro-channels shows uniform cross-section in primary flow direction. Local Nusselt number is examined for thermal characteristics of each membrane, and module average Nusselt number and friction factor are calculated to determine the characteristics of the heat transfer and pressure drop in overall flat tube with microchannels. The correlations between Nusselt number and friction factor are given by Reynolds number, aspect ratio of membranes, and the width of flat tube. ALM (Augmented Lagrangian Multiplier) method is applied to the correlations to determine an optimal shape of flat tube. It is shown that the optimal aspect ratio of flat tube is approximately 1.0, irrespective of the width of flat tube and Reynolds number.

Effect of Thermal Contact Resistence on the Heat Transfer Characteristics of Air Flow around the Finned Micro-Channel Tube for MF Evaporator (Micro-Channel형 열교환기에 부착된 핀의 열접촉저항이 열전달 특성에 미치는 영향)

  • Park, Yong-Seok;Sung, Hong-Seok;Sung, Dong-Min;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.121-126
    • /
    • 2021
  • In this study, the effect of thermal contact resistance between pin-channel tubes on the heat transfer characteristics was analytically examined around the channel tubes with the pins attached to two consecutive arranged channel pipes. The numerical results showed that the heat transfer coefficient decreased geometrically as the thermal contact resistance increased, and the corresponding temperature change on the contact surface increased as the thermal contact resistance increased. The thinner the pin, the more pronounced the geometric drop in the heat transfer coefficient. It was confirmed that the higher the height of the pin, the higher was the heat transfer coefficient, however, the greater the size of the thermal contact resistance, the smaller was the heat transfer coefficient. It was found that the temperature change in the inner wall of the channel tube did not significantly affect the heat transfer characteristics owing to the thermal contact resistance. Furthermore, the velocity of air at the entrance of the channel tube was proportional to the heat transfer coefficient due to a decrease in the convective heat resistance corresponding to an increase in the flow rate.

Effect on Boiling Bleat Transfer of Horizontal Micro-channel Diameters for R-22 and R-407C (수평미세관의 직경이 R-22 및 R-407C 비등열전달에 미치는 영향)

  • Yoon, Kuk-Young;Choi, Kwang-Il;Oh, Jong-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.163-172
    • /
    • 2003
  • Boiling heat transfer coefficients and pressure drops for R-22 and R-407C were measured in horizontal micro-channels. The test section is stainless steel tube, inner tube diameters are 1.8mm and 2.8mm, and the respective lengths are 1500mm and 3000mm. The range of mass flux is 300-600kg/$m^2$s and heat flux is 5-15kW/$m^2$. In this results, pressure drop increased linearly for both R-22 and R-407C with increased mass flux, but the increase of heat flux did not affect the pressure. In addition, the pressure drop was fairly increased in the high quality region rather than low quality region. In the range of low quality, the mass flux had a small affect on the heat transfer coefficients, however, in high quality region, the heat transfer coefficients increased even more with increasing mass flux. Under the low quality region and low mass flux, the heat transfer coefficients increased with increasing heat flux densities. The effects of inner tube diameter were clearly observed. Namely, the measured pressure drop inside inner tube diameter 1.8 mm is higher than 2.8 mm with increasing the mass flux and heat flux. Also, the measured local heat transfer coefficient inside inner tube diameter 1.8 mm is higher than 2.8 mm in the range of high qualities. The experimental data for R-407C compared with proposed correlation using pure refrigerant. The experimental data for R-407C was more decreased than the proposed correlation for pure refrigerant up to 50% or more.

Development of design technique for automotive condenser (자동차용 에어컨 응축기의 설계기술 개발)

  • Cho, Y.D.;Han, C.S.;Yoo, S.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 1999
  • The present work presents condensation heat transfer and pressure drop data for the flow of R-12 in flat extruded aluminum tubes with small hydraulic diameters. The tube outside dimensions are $18mm(width){\times}1.7mm(height)$. Three types of internal geometry with the same outside dimensions are tested : sample 1 (7 tube holes), sample 2 (13 tube holes) and sample 3 (7 tube holes, micro-fin). The overall heat transfer coefficient is obtained for air-to-refrigerant heat transfer, and the Wilson plot method is used to determine the heat transfer coefficient for refrigerant flow. The sample 2 and sample 3 show significantly higher performance than sample 1. The heat transfer rates for the sample 2 and sample 3 are 9% and 12% higher, respectively, than sample 1. The friction factors for the sample 2 and sample 3 are 11.9% and 2.4% higher, respectively, than sample 1.

  • PDF

Investigation of Single Phase Frictional Pressure Loss in Circular Micro Tubes

  • Han Dong-Hyouck;Lee Kyu-Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1284-1291
    • /
    • 2006
  • Single phase pressure drops in micro tubes were investigated through an experimental measurement and a numerical simulation. Experimental Po was obtained in circular micro tubes with 87 and $118{\mu}m$ diameter with distilled water. Experiments were carried out in laminar flow region with varying the Re 15-450 for the $87{\mu}m$ diameter tubes and 60-1300 for the $118{\mu}m$ diameter tube. No early transition from laminar to turbulent flow was detected for the experimental range. The computational estimation of pressure drop in the $87{\mu}m$ diameter tube was performed with the aid of CFD software. Boundary conditions from experiments were used for the numerical simulation. The results of experimental and numerical studies showed a good agreement with the conventional macro theory.

Experimental Study on Cooling Performance of Internal Heat Exchanger for CO2 Refrigerant System (이산화탄소 냉매 시스템용 내부 열교환기의 냉방성능에 관한 실험적 연구)

  • Kim, Dae-Hoon;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.587-592
    • /
    • 2008
  • In order to investigate the performance of an internal heat exchanger for $CO_2$ refrigerant system, the experiment was performed. Four kinds of internal heat exchangers(IHX) were used. The effects on the IHX length, the number of tube, the operating condition and the type of IHX were investigated. With increasing of the IHX length, the capacity and efficiency increased. The pressure drop of the low-side was larger compared with that of the high-side. As the temperature of the gas cooler increased, the capacity and efficiency increased linearly. The operation condition of evaporator was suggested as two phase region rather than superheat region. The capacity and efficiency of the micro-channel was larger about 90% and 75% than those of the tube. But the pressure drop of the micro-channel was more larger, compared with that of the tube.

Study on Heat Transfer and Pressure Drop Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Cooling Condition ($CO_2$ 열펌프용 내부 열교환기의 냉방조건에서 열전달 및 압력 강하 특성에 대한 연구)

  • Kim, Dae-Hoon;Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.517-525
    • /
    • 2008
  • In order to study the heat transfer and pressure drop of an internal heat exchanger for $CO_2$ heat pump under cooling condition, the experiment and numerical analysis were performed. Four kinds of internal heat exchangers with a coaxial tube type and a micro-channel tube type were used. The experimental apparatus consisted of a test section, a power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of the internal heat exchanger refrigerant flow rate, the length of the internal heat exchanger, the operating condition of the gas-cooler, the evaporator and the type of the internal heat exchangers were investigated. With increasing of the flow rate, the heat transfer rate increased about 25%. The heat transfer rate of the micro-channel tube type was higher about 100% than that of the coaxial tube type. With increasing of the length of the internal heat exchanger, the heat transfer rate increased about $20{\sim}50%$. The pressure drop of the low-side tube was larger compared with that of the high-side tube.