• 제목/요약/키워드: Micro cavity

검색결과 178건 처리시간 0.023초

금형 내부 압력 최소화를 위한 자동차 인스트루먼트 패널의 게이트 위치 최적화 (Gate Locations Optimization of an Automotive Instrument Panel for Minimizing Cavity Pressure)

  • 조성빈;박창현;표병기;최동훈
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.648-653
    • /
    • 2012
  • Cavity pressure, an important factor in injection molding process, should be minimized to enhance injection molding quality. In this study, we decided the locations of valve gates to minimize the maximum cavity pressure. To solve this problem, we integrated MAPS-3D (Mold Analysis and Plastic Solution-3Dimension), a commercial injection molding analysis CAE tool, using the file parsing method of PIAnO (Process Integration, Automation and Optimization) as a commercial process integration and design optimization tool. In order to reduce the computational time for obtaining the optimal design solution, we performed an approximate optimization using a meta-model that replaced expensive computer simulations. To generate the meta-model, computer simulations were performed at the design points selected using the optimal Latin hypercube design as an experimental design. Then, we used micro genetic algorithm equipped in PIAnO to obtain the optimal design solution. Using the proposed design approach, the maximum cavity pressure was reduced by 17.3% compared to the initial one, which clearly showed the validity of the proposed design approach.

초음파 기구에 의한 치근단 와동형성후 역충전의 밀폐성에 대한 연구 (A COMPARATIVE STUDY ON THE APICAL LEAKAGE OF RETROFILLING AFTER APICAL CAVITY PREPARATION WITH ULTRASONIC INSTRUMENT)

  • 이형일;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.197-204
    • /
    • 1993
  • This study was conducted to evaluate and compare the apical leakage in the following retrofilling techniques after apical resection; No apical cavity preparation and no retrofilling(control group), Amalgam(group I) or silver glass ionomer cement(group II) retrofilling after apical cavity preparation with mini contra-angle and bur, Amalgam(group III) or silver glass ionomer cement(group N) retrofilling after apical cavity preparation with ultrasonic micro endo tip. Extracted ninety upper anterior and lower canine teeth were fixed in skull simulators and root canals were prepared with step-back method and obturated with gutta-percha and zinc oxide eugenol sealer. Obturated roots were resected 2mm from apical ends and apical cavities of 1mm width and 2mm depth were prepared and retrofilled by above mentioned methods. After application of nail varnish on all surface except resected surface, apical 1/3 of the roots were placed in 1% methylene blue solution for 3 days. After longutudinal sectioning to expose central parts of filled materials, depths of penetrated dye were measured by measuring microscope and were analyzed statistically. The results were as follows. 1. Having no relation with instruments used in apical cavity preparation, amalgam retrofilling groups(group I and II) showed less apical leakage which was not significant statistically than no retrofilling group(control group) (P<0.05), but silver glass ionomer cement retrofilling gruoups(group II and IV) showed significantly less apical leakage than no retrofilling group(control group) (P<0.01). 2. In the groups retrofilled with the same material, the apical leakage in cavities prepared with ultrasonic micro endo tip (group III and IV) was less than that in cavities prepared with mini contra-angle and bur(group I and II), but not significant statistically(P>0.05). 3. When apical cavities were prepared with same instrument. the egroups retrofilled with silver glass ionomer cement(group II and IV) showed significantly less apical leakage than the groups retrofilled with amalgam(group I and III)(<0.01).

  • PDF

Micro-Cavity Effect of ZnO/Ag/ZnO Multilayers on Green Quantum Dot Light-Emitting Diodes

  • Lee, Hyungin;Kim, Jiwan
    • 한국세라믹학회지
    • /
    • 제55권2호
    • /
    • pp.174-177
    • /
    • 2018
  • ZnO/Ag/ZnO multilayers were fabricated and their optical properties were investigated in terms of the micro-cavity effect in electroluminescent devices based on colloidal quantum dots. The top and bottom ZnO layers were formed by a sol-gel method while the middle Ag layer was deposited by thermal evaporation. After the fabrication of the ZnO/Ag/ZnO structure, the transmittance increased to 74%. When the oxide/metal/oxide multilayers were applied to quantum dot light-emitting diodes, the color purity was enhanced due to the narrower full width at half maximum.

광결정 공진기와 링 공진기의 공진특성 결합을 통한 바이오센서 응용 (Applied of Integrated Optical Biosensor based on Combination of Photonic Crystal Micro-Cavity and Ring Resonator)

  • 김홍승;김두근;오금윤;이태경;최영완
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.817-822
    • /
    • 2011
  • We propose a novel ring structure based on the stadium-shaped ring resonator (SSRR) with dual photonic crystal microcavity (DPCM) for biosensor and analyzed the sensing characteristics. The Q-factor of the photonic crystal microcavity (PCM) can be significantly enhanced when the PCM or DPCM has the same resonance condition as the SSRR. The simulation results show that the Q-factor of the SRR with DPCM was increased by three times in comparison with single PCM structure. We also defined a mutual interference between two PCMs. Assuming a detectable spectral resolution of 10 picometers, a refractive index resolution of $3.03\times10-5$ can be measured on the SSRR-DPCM.

Cavity를 갖는 SDB SOI 구조의 제작 (Fabrication of SDB SOI structure with sealed cavity)

  • 강경두;정수태;주병권;정재훈;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.557-560
    • /
    • 2000
  • Combination of SDB(Si-wafer Direct Bonding) and electrochemical etch-stop in TMAH anisotropic etchant can be used to create a variety of MEMS(Micro Electro Mechanical System). Especially, fabrication of SDB SOI structures using electrochemical etch-stop is accurate method to fabrication of 3D(three-dimensional) microstructures. This paper describes on the fabrication of SDB SOI structures with sealed cavity for MEMS applications and thickness control of active layer on the SDB SOI structure by electrochemical etch-stop. The flatness of fabricated SDB SOI structure is very uniform and can be improved by addition of TMAH to IPA and pyrazine.

  • PDF

무산소동의 초정밀 절삭 특성을 이용한 아노드 및 캐비티의 가공 (Machining of Anode and Cavity applying Ultraprecision Machining Characteristics of OXFC)

  • 원종호;김주환;박순섭;김건희;김상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.922-925
    • /
    • 2002
  • Klystron which is micro wave amplifier tube are mainly used in fields of science such as accelerator, nuclear fusion, broadcasting, communication fields, and defense industry fields, tract. The quality of Klystron anode and cavity are determined by form accuracy and roughness of the worked surface. Therefore anode and cavity are restricted the from accuracy strictly and the surface roughness be under Rmax 0.03S. As a work material of anode and cavity, the oxygen-free copper, that is used for optical pares of aerospace and laser mirror is selected. An outside diameter of material is $\Phi$100 mm and an inside diameter is $\Phi$30~33 mm. In this study, to find the optimum ultra precision cuffing condition of oxygen-free copper with diamond turning machine, the surface roughness is examined for various diamond toot nose radius, main spindle speed, fred rate and depth of cut. As a result of experiment, we could machined the anode and cavity with a surface roughness within Ra 3.2 nm, a form accuracy within 0.01 $\mu\textrm{m}$.

  • PDF

Substrate-integrated-waveguide cavity-backed circularly polarized antenna with enhanced bandwidth and gain

  • Shankaragouda M. Patil;Rajeshkumar Venkatesan
    • ETRI Journal
    • /
    • 제46권3호
    • /
    • pp.404-412
    • /
    • 2024
  • We propose a method for increasing the bandwidth of a substrate-integrated-waveguide (SIW) cavity-backed antenna with taper-based micro-strip SIW transition feeding. For radio transmission, a circular slot is etched on top of the SIW cavity. For optimal antenna design, the slot is etched slightly away from the cavity center to generate circularly polarized waves. Simulations show a wide axial ratio bandwidth of 7.860% between 11.02 GHz and 11.806 GHz. Experimental results confirm a similar wide axial ratio bandwidth of 4.9% between 10.8 GHz and 11.35 GHz. An SIW feed from an inductive window excites the radiating circular slot, resulting in a simulated wide impedance range of 1.548 GHz (10.338 GHz-11.886 GHz) and bandwidth of 13.93%. Experimental results show a wide impedance of 2.08 GHz (10.2 GHz-12.08 GHz) and bandwidth of 18.84%. The SIW cavity-backed antenna creates a unidirectional pattern, leading to gains of 6.61 dBi and 7.594 dBi in simulations and experiments, respectively. The proposed antenna was fabricated on a Rogers RT/Duroid 5880 substrate, and the reflection coefficient, radiation patterns, and gains were tested and compared using a computer simulator. The developed broadband antenna seems suitable for X-band applications.

미세 방전 가공을 이용한 반구형 전극 제작 (Half spherical electrode machining in micro EDM)

  • 김기현;주종남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1080-1084
    • /
    • 2001
  • In manufacturing a micro die with half spherical cavity by MEDM, it is necessary to prepare an electrode with the same shape. This paper suggests a simple method to manufacture a half spherical electrode based on tool wear. The tool wears more rapidly at the edge of a cylindrical electrode. In order to make a half spherical micro electrode, cylindrical electrode was fed into the workpiece by the distance of its radius. The d/R(depth/Radius) value varied with respect to capacitance and electrode diameter. The smaller the size of electrode was, the closer the electrode tip geometry approached to a half sphere.

  • PDF

금형온도에 의한 미세패턴 성형 특성에 관한 연구 (Put English Title Here)

  • 김창완;유영은;권기환;제태진;최두선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1129-1131
    • /
    • 2008
  • We injection molded a plate with micro surface features including micro prizms & micro channels patterns on its surface and investigated the replication of the micro features depending on the mold temperature which is one of typical process parameters. The size of the patterns were 8um, 10um, 15um of prizm features & 15um, 30um, 45um of channel features. The size of the plate is about $400mm{\times}400mm$ and the thickness is 1mm of plate. the repliction of the mucro features turned out to depend on the mold temperature and also the location on the plate. The pressure and the feature of the melt in the cavity were also measured in real-time for the investigation on the micro feature replication.

  • PDF