• 제목/요약/키워드: Micro Valve

검색결과 105건 처리시간 0.029초

마이크로 박판 밸브 성형을 위한 마이크로 프레스 개발 (Development of Micro Press for Forming the Micro Thin Foil Valve)

  • 이혜진;이낙규;이형욱
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.166-171
    • /
    • 2007
  • In this paper Research development about a micro metal forming manufacturing system has been developed. A micro forming system has been achieved in Japan and it's developed micro press is limited to single forming process. To coincide with the purpose to be more practical, research and development is necessary about the press which the multi forming process is possible. We set the development of the equipment including micro deep drawing, micro punching and micro restriking process to the goal. To achieve this goal, we set the application product to a micro thin foil valve which is used in the micro pump module. The compound die set has been designed and manufactured to make two step process. The material of thin foil valve is SUS-304 and its thickness is 50$\mu$m. We can get a good forming results from micro punching experiments in this paper.

A Micro Shunt Valve with Anti-siphon Effect

  • Lee, Sang-Wook;Yoon, Hyeun-Joong;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.31-34
    • /
    • 2004
  • This paper presents the fabrication and testing of a two-way pressure regulation micro shunt valve with an anti-siphon effect that can be implanted in hydrocephalus patients. This micro shunt valve consists of a silicone rubber membrane and a valve seat for the opening pressure control as well as the anti-siphon behavior. The two-way pressure regulation and the anti-siphon effect of the micro shunt valve are verified experimentally for various sizes of membranes and valve seats.

Polymer MEMS 공정을 이용한 의료용 미세 부품 성형 기술 개발 (Development of micro check valve with polymer MEMS process for medical cerebrospinal fluid (CSF) shunt system)

  • 장준근;박찬영;정석;김중경;박훈재;나경환;조남선;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1051-1054
    • /
    • 2000
  • We developed the micro CSF (celebrospinal fluid) shunt valve with surface and bulk micromachining technology in polymer MEMS. This micro CSF shunt valve was formed with four micro check valves to have a membrane connected to the anchor with the four bridges. The up-down movement of the membrane made the CSF on & off and the valve characteristic such as open pressure was controlled by the thickness and shape of the bridge and the membrane. The membrane, anchor and bridge layer were made of the $O_2$ RIE (reactive ion etching) patterned Parylene thin film to be about 5~10 microns in thickness on the silicon wafer. The dimension of the rectangular nozzle is 0.2*0.2 $\textrm{mm}^2$ and the membrane 0.45 mm in diameter. The bridge width is designed variously from 0.04 mm to 0.12 mm to control the valve characteristics. To protect the membrane and bridge in the CSF flow, we developed the packaging system for the CSF micro shunt valve with the deep RIE of the silicon wafer. Using this package, we can control the gap size between the membrane and the nozzle, and protect the bridge not to be broken in the flow. The total dimension of the assembled system is 2.5*2.5 $\textrm{mm}^2$ in square, 0.8 mm in height. We could precisely control the burst pressure and low rate of the valve varing the design parameters, and develop the whole CSF shunt system using this polymer MEMS fabricated CSF shunt valve.

  • PDF

7mm폭의 Micro Valve 자장 및 유동특성 고찰 (An Investigation into Micro Valve Field and Flow Field Characteristic of 7mm Width)

  • 전용식;김동수;신동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.657-658
    • /
    • 2006
  • Recently, the micro on-off valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for micro valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate micro on-off valve using the analogy of equivalent magnetic circuit and Finite Element Method(FEM) respectively. In case of poppet, flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

원심력기반 3차원 관성밸브 모델링을 통한 정밀 미세유체제어 (3D-inertia Valve Component for Centrifugal Force-based Micro Fluid Control)

  • 강동희;김나경;강현욱
    • 한국가시화정보학회지
    • /
    • 제19권1호
    • /
    • pp.12-17
    • /
    • 2021
  • A three-dimensional slope valve component is used for controlling micro volume of liquid on a centrifugal force-based microfluidic disk platform, also called a lab-on-a-disk. The modeling factor of the slope valve component is determined to centrifugal force for liquid passing the crest of a slope valve via variation of slope length and angle as well as the radius to start point of slope valve. The centrifugal force is calculated by the equilibrium equation of the capillary and gravitational forces according to the microchannel surface roughness and the liquid volume, respectively. As a result, the slope valve is analyzed by the minimum angular velocity for liquid passing at crest point and the ratio between the length of micro liquid and slope length to obtain the factors for optimal slope angle modeling.

기능성 액츄에이터를 이용한 마이크로 밸브 (Micro Valve with Functional Actuator)

  • 윤소남;함영복;이경우;칸다 쿠니오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.951-955
    • /
    • 2004
  • Piezoelectric(PZT) actuator can substitute for solenoid which is used in fluid control field because it has faster response times and no possibility of explosion. Besides, it is available in a high temperature and it has low energy consumption. In this study, pneumatic micro valve, bimorph type PZT actuator using the softner type PZT, carbon plate as a shim and its controller circuit were suggested and investigated. Performance tests and characteristics analysis, such as displacement, force, hysteresis and frequency properties, were carried out. The displacement of the actuator measured at the end point was 63 ${\mu}m$., force of the actuator was 0.052 N and maximum operating frequency was 15Hz. Also, characteristics of the micro valve with PZT actuator were evaluated in a testing system. The results show that the suggested PZT actuator is suitable for micro valve.

  • PDF

열모세관에 의한 미소액적 구동과 모세관 밸브 (Micro droplet driven by thermocapillary and capillary valve)

  • 임남혁;김성욱;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1777-1782
    • /
    • 2003
  • This paper presents the design, fabrication, and testing of the capillary-induced pressure drop valve, thermocapillary pumping of liquid droplet in hydrophilic channels and the splitting of droplet. The capillaryinduced pressure drop is derived with thermodynamic approach considering three-dimensional meniscus shape which is essential for calculating pressure drop in the diverging shape channel when the aspect ratio is close to one. The micro channel is fabricated via MEMS processes, which consists of the liquid stop valve to retard the liquid droplet, thermocapillary pumping region and the bifurcation region. Also the micro heaters are fabricated to drive the droplet by thermocapillary. The theoretical approaches agree well with the experimental data. The functionality of capillary valve is confirmed to be valid when the aspect ratio is smaller than one. To overcome the difficulty in splitting of the droplet due to the pressure drop in the general Y-shape channel, the protrusion shape is employed for easy splitting in the bifurcation channel.

  • PDF

바이오용 압전디스크방식 마이크로 펌프 설계 및 제작(I) -링형 플랩밸브 모듈의 최적설계- (Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (I): Optimal Design of Ring-shaped Flab Valve Module)

  • 김형진;서영호;김병희
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.355-361
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, it has some intrinsic disadvantages such as backward flow, pulsation of flow, low repeatability and producibility, and high cost. To overcome these limitation, a PZT disc actuated micro pump including a novel ring-shaped multi-flap check valve is introduced. To enhance the performance of the micro pump, the static behaviour of flap valve module and the micro fluidic behavior of fluids are numerically modelled and analyzed. As results of the numerical analysis, the optimal dimension and configuration of the ring-shaped multi flap valve are $1{\times}0.05$ mm and 2 (inlet side)${\times}1$ (outlet side) type. The obtained maximum flow rates and flow resolution are about 90 ml/min and 30 ${\mu}l$/stroke respectively.

Micro Valve 설계 및 해석

  • 서현석;김동수;최병오;박상운;김현섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 추계학술대회 논문요약집
    • /
    • pp.151-151
    • /
    • 2003
  • PDF

Micro On-Off Valve 해석에 의한 최적 설계 (The optimal design by Micro On-Off Valve analysis)

  • 김동수;박상운;고창섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.285-290
    • /
    • 2005
  • Micro On-Off valves are currently recognized as the core technology in the fields of the micro fluid chip fur medical applications and production lines of semi-conduct chip. Micro valves that operate by compressed air need the high-speed responsibility, repeatability, the absorbability and the uniform pressure by the poppet. In this study, Micro On-Off valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.