• 제목/요약/키워드: Micro Test

검색결과 2,146건 처리시간 0.035초

SMA 메쉬 와셔를 적용한 수동형 진동절연기의 미소진동 절연성능 검증 (Micro-vibration Isolation Performance Verification for the Passive Vibration Isolator using SMA Mesh Washer)

  • 권성철;전수현;오현웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.900-903
    • /
    • 2014
  • Fly-wheel, Gimbal antenna, CMG, Spaceborne cyrocooler generate micro-vibration during their on-orbit operation as well as implementing their own function. To comply with the mission requirement of high resolution observation satellite, additional technical efforts have been required to isolate the micro-vibration derived from such payloads by applying the vibration isolator. In this study, we proposed a passive isolator using SMA mesh washer, which guarantees the structural safety of both micro-vibration disturbance source and itself under harsh launch vibration loads without an additional holding mechanism and the micro-vibration isolation performance on orbit environment. To verify the micro-vibration isolation performance of the proposed vibration isolator, we performed the micro-vibration isolation measurement test using the dedicated micro-vibration measurement device proposed in this study.

  • PDF

Limited Diagnostic Value of microRNAs for Detecting Colorectal Cancer: A Meta-analysis

  • Zhou, Xuan-Jun;Dong, Zhao-Gang;Yang, Yong-Mei;Du, Lu-Tao;Zhang, Xin;Wang, Chuan-Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권8호
    • /
    • pp.4699-4704
    • /
    • 2013
  • Background: MicroRNAs have been demonstrated to play important roles in the development and progression of colorectal cancer. Several studies utilizing microRNAs as diagnostic biomarkers for colorectal cancer (CRC) have been reported. The aim of this meta-analysis was to comprehensively and quantitatively summarize the diagnostic value of microRNAs for detecting colorectal cancer. Methods: We searched PubMed, Embase and Cochrane Library for published studies that used microRNAs as biomarkers for the diagnosis of colorectal cancer. Summary estimates for sensitivity, specificity and other measures of accuracy of microRNAs in the diagnosis of colorectal cancer were calculated using the bivariate random effects model. A summary receiver operating characteristic (SROC) curve was also generated to summarize the overall effectiveness of the test. Result: Thirteen studies from twelve published articles met the inclusion criteria and were included. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odd ratio of microRNAs for the diagnosis of colorectal cancer were 0.81 (95%CI: 0.79-0.84), 0.78 (95%CI: 0.75-0.82), 4.14 (95%CI: 2.90-5.92), 0.24 (95%CI: 0.19-0.30), and 19.2 (95%CI: 11.7-31.5), respectively. The area under the SROC curve was 0.89. Conclusions: The current evidence suggests that the microRNAs test might not be used alone as a screening tool for CRC. Combining microRNAs testing with other conventional tests such as FOBT may improve the diagnostic accuracy for detecting CRC.

반작용휠의 미소진동 측정법에 관한 실험적 연구 (An Experimental Study on Micro-vibration Measurement Methods of a Reaction Wheel)

  • 김대관;오시환;이선호;용기력
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.828-833
    • /
    • 2011
  • A reaction wheel assembly(RWA) is the largest disturbance source that can induce high frequency micro-vibration on an optical payload of satellites. To ensure a tight pointing-stability budget of satellites, the RWA disturbance effect on spacecraft should be accurately analyzed and evaluated for whole design phases. For this purpose, the micro-vibration disturbance of RWA should be precisely measured. In the present study, two measurement methods on RWA micro-vibration disturbances are compared and investigated. One is a free run-down speed test and the other is a constant speed test. The micro-vibration data measured by the two methods are analyzed in terms of spectrum characteristics, static and dynamic imbalance values, and root sum square(RSS) values. The analysis results show that both methods can measure very similar results in time and frequency domains and that the free run-down speed method is more adequate in respects to wheel friction modeling, noise rejection of imbalance and RSS peak evaluation.

미소경도 측정에 의한 590DP강 Subsurface Zone 내 수소취성 평가 (Hydrogen Embrittlement Evaluation of Subsurface Zone in 590DP Steel by Micro-Vickers Hardness Measurement)

  • 최종운;박재우;강계명
    • 한국재료학회지
    • /
    • 제21권11호
    • /
    • pp.581-586
    • /
    • 2011
  • This study describes a hydrogen embrittlement evaluation of the subsurface zone in 590DP steel by micro-Vickers hardness measurement. The 590DP steel was designed to use in high-strength thin steel sheets as automotive materials. The test specimens were fabricated to 5 series varying the chemical composition through the process of casting and rolling. Electrochemical hydrogen charging was conducted on each specimen with varying current densities and charging times. The relationship between the embrittlement and hydrogen charging conditions was established by investigating the metallography. The micro-Vickers hardness was measured to evaluate the hydrogen embrittlement of the subsurface zone in addition to the microscopic investigation. The micro-Vickers hardness increased with the charging time at the surface. However, the changing ratio and maximum variation of hardness with depth were nearly the same value for each test specimen under the current density of 150 mA/$cm^2$ and charging time of 50 hours. Consequently, it appears that hydrogen embrittlement in 590DP steel can be evaluated by micro-Vickers hardness measurement.

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

고강도 숏크리트의 품질평가와 복합열화시험을 통한 장기내구성 검토 (An Investigation on the Quality of High-Strength Shotcrete and the Long Term Durability using Combined Deterioration Test)

  • 마상준;김동민;최재석;안경철;김선명;고진곤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.906-915
    • /
    • 2006
  • In this study, Field test was performed using high-quality additions and accelerators to obtain the improvement of the strength on domestic shotcrete and quality test based on EFNARC was performed. In addition, Deterioration test that combined the Freezing-thawing and Carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of field test, a promotion ratio of early strength is $90\sim97%$ in case of using alkali-free accelerators. And a compressive strength of shotcrete using Micro-silica fume was $45.2\sim55.8MPa$ and the flexible strength was $5.01\sim6.66MPa$, so a promotion ratio of strength was $37\sim79%$, $17\sim61%$ respectively. It was showed that increment effect of strength by the Micro-silica fume replacement of $7.5\sim10%$ for cement mass was remarkable. It was also realized that application of Micro-silica fume to shotcrete reduced deterioration and improved a long-term durability of shotcrete.

  • PDF

A study on thermo-mechanical behavior of MCD through bulge test analysis

  • Altabey, Wael A.
    • Advances in Computational Design
    • /
    • 제2권2호
    • /
    • pp.107-119
    • /
    • 2017
  • The Micro circular diaphragm (MCD) is the mechanical actuator part used in the micro electro-mechanical sensors (MEMS) that combine electrical and mechanical components. These actuators are working under harsh mechanical and thermal conditions, so it is very important to study the mechanical and thermal behaviors of these actuators, in order to do with its function successfully. The objective of this paper is to determine the thermo-mechanical behavior of MCD by developing the traditional bulge test technique to achieve the aims of this work. The specimen is first pre-stressed to ensure that is no initial deflection before applied the loads on diaphragm and then clamped between two plates, a differential pressure (P) and temperature ($T_b$) is leading to a deformation of the MCD. Analytical formulation of developed bulge test technique for MCD thermo-mechanical characterization was established with taking in-to account effect of the residual strength from pre-stressed loading. These makes the plane-strain bulge test ideal for studying the mechanical and thermal behavior of diaphragm in both the elastic and plastic regimes. The differential specimen thickness due to bulge effect to describe the mechanical behavior, and the temperature effect on the MCD material properties to study the thermal behavior under deformation were discussed. A finite element model (FEM) can be extended to apply for investigating the reliability of the proposed bulge test of MCD and compare between the FEM results and another one from analytical calculus. The results show that, the good convergence between the finite element model and analytical model.

마이크로 코일 스프링의 스프링 상수 평가 (Evaluation of the Spring Constant of a Micro Coil Spring)

  • 이종길;전병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 2001
  • The spring constant of a micro coil spring was measured by uniaxial tensile test. The inner diameter of it is $35{\mu}m$ and the pitch size is about $23{\mu}m$. A suing constant measurement system was developed. It consists of control units, load cell units, linear stages and several specially designed jigs and fixtures. Load and displacement are measured using a commercial load cell of 1000g capacity and a magnetic scale of $0.5{\mu}m$ resolution. In this study, a method to measure the spring constant of micro coil spring is presented and the relationship between misalignment of specimen and measurement error is discussed.

  • PDF

미세 엔진 운용성 검증 및 요소 기술 개발 (Fabrication and feasibility estimation of Micro Engine Component)

  • 이대훈;박대은;최권형;윤준보;권세진;윤의식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.31-36
    • /
    • 2001
  • As a part of micro engine development feasibility estimation was done through fabrication and test of down scaled combustor and MEMS fabricated spark electrode. In an experimental observation of the down scaled combustion phenomena where flame propagation was observed by optical method and pressure change in combustor which gives the information about the reaction generated thermal energy was recorded and analyzed. Optimal combustor scale was derived to be about 2mm considering increased heat loss effect and thermal energy generation capability. Through the fabrication and discharge test of MEMS electrode effects of electrode width and gap was investigated. Electrode was fabricated by thick PR mold and electroplating. From the result discharge voltage characteristic in sub millimeter scale electrode having thickness of $40{\mu}m$ was obtained. From the result base technology for design and fabrication of micro engine was obtained.

  • PDF

미세 X선 단층촬영 기법의 개발과 적용 (Development of X-ray Micro Computed Tomography and Applications)

  • 김승곤;임재홍;김보흠;이의재;이상준
    • 한국가시화정보학회지
    • /
    • 제8권2호
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.