• 제목/요약/키워드: Micro Test

검색결과 2,128건 처리시간 0.033초

세침의 예리도 시험에서의 정렬 오차 영향 평가 (Evaluation of the Influence of Alignment Error in the Sharpness Test of a Micro-Needle)

  • 이종길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.250-253
    • /
    • 2004
  • Sharpness of the tip of micro needle is very Important quality that should be controlled in the manufacturing processes. Acupuncture needle is one of the most widely used micro-needle. And the tip sharpness of acupuncture needle Is usually checked by the magnitude of resisting force obtained through sharpness test. In this study, some sharpness tests of acupuncture needle were done and the relationship between the misalignment of specimen and the magnitude of resisting force. The diameter of the needle used in the test was $250\;{\mu}m$ and the length of it was 40 mm.

  • PDF

TAMAM 반작용휠의 미소진동 측정 및 분석 (TAMAM RWA Micro-Vibration Test and Analysis)

  • 오시환;이승우;최홍택;이선호;용기력
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.836-839
    • /
    • 2003
  • In this paper, we briefly introduce the test bench and test method of RWA micro-vibration. TAMAM RWA (Reaction Wheel Assembly) micro-vibration was measured on a KISTLER dynamic plate which can measure time signals of three orthogonal forces and torques simultaneously up to 400Hz, and test data was analyzed. Measured data were evaluated with respect to the wheel spin rate and the static/dynamic unbalances were estimated from the extracted first harmonic component. The estimated static and dynamic unbalances were 0.79gㆍcm and 17.4gㆍ$\textrm{cm}^2$ respectively. The resonance mode and two rocking modes were observed as a results of its frequency analysis. Several higher order harmonic components were observed, which comes from its rotor shape as well as the wheel bearing.

  • PDF

경량콘크리트를 사용한 충전용 재료의 공학적 특성 (Engineering Characteristics of Filling Materials using Lightweight Foamed Concrete)

  • 도종남;강형남;서두원;천병식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.519-523
    • /
    • 2009
  • In this study, the base mixing ratio was determinated to estimate the optimal mixing ratio of material with a change of mixing ratio of micro cement, sand, foaming agent, plasticizer by testing the unconfined compressive strength test. The unconfined compressive strength test was performed to grasp a engineering characteristics of with a change of micro cement, bubble. The results of test, the unconfined compressive strength increased with a micro cement's increase and bubble's decrease. In the future, it will be secured that is reliable datas from laboratory of various condition and in-situ tests to develop optimal lightweight foamed concrete.

  • PDF

IPA 저온 접합법을 이용한 PMMA Micro CE Chip의 제작 (Fabrication of PMMA Micro CE Chip Using IPA Assisted Low-temperature Bonding)

  • 차남구;박창화;임현우;조민수;박진구
    • 한국재료학회지
    • /
    • 제16권2호
    • /
    • pp.99-105
    • /
    • 2006
  • This paper reports an improved bonding method using the IPA (isopropyl alcohol) assisted low-temperature bonding process for the PMMA (polymethylmethacrylate) micro CE (capillary electrophoresis) chip. There is a problem about channel deformations during the conventional processes such as thermal bonding and solvent bonding methods. The bonding test using an IPA showed good results without channel deformations over 4 inch PMMA wafer at $60^{\circ}C$ and 1.3 bar for 10 minutes. The mechanism of IPA bonding was attributed to the formation of a small amount of vaporized acetone made from the oxidized IPA which allows to solvent bonding. To verify the usefulness of the IPA assisted low-temperature bonding process, the PMMA micro CE chip which had a $45{\mu}m$ channel height was fabricated by hot embossing process. A functional test of the fabricated CE chip was demonstrated by the separation of fluorescein and dichlorofluorescein. Any leakage of liquids was not observed during the test and the electropherogram result was successfully achieved. An IPA assisted low-temperature bonding process could be an easy and effective way to fabricate the PMMA micro CE chip and would help to increase the yield.

미세전류 자극이 얼굴 피부개선에 미치는 영향에 관한 임상시험 연구 (Clinical Test for Evaluation of Effectiveness of the Micro-current Stimulation in Facial Skin Care)

  • 조승관;김성국;김용민;박세근;이지환;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.195-207
    • /
    • 2016
  • This study examined the effectiveness of micro-current stimulation (MCS) to improve the facial skin qualities by performing clinical test. The MCS is generally known that provide healing response in the damaged tissue and pain relief through activating the adenosine triphosphate (ATP) and protein synthesis. In here, we can hypothesize that the improvement of facial skin qualities may occur due to MCS, since the induction of micro-current from outside may enhance the cellular activity according to ATP activation. From the clinical test, our results showed that a variety of evaluating categories, which is able to assess the skin qualities, significantly enhanced due to stimulation of micro-current after 7 and 14 days. Therefore, we can estimate that MCS in human facial skin may be effective to improve the skin qualities.

단결정 실리콘 박막의 미소인장 물성 평가 (Micro-tensile Test for Micron-sized SCS Thin Film)

  • 이상주;한승우;김재현;이학주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.45-48
    • /
    • 2008
  • The mechanical behavior of small-sized materials has been investigated for many industrial applications, including MEMS and semiconductors. It is challenging to obtain accurate mechanical properties measurements for thin films due to several technical difficulties, including measurement of strain, specimen alignment, and fabrication. In this work, we used the micro-tensile testing unit with the real-time DIC (Digital Image Correlation) strain measurement system. This system has advantages of real time strain monitoring up to 50 nm resolution during the micro-tensile test, and ability to measure the young's modulus and Poisson's ratio at the same time. The mechanical properties of SCS (Single Crystal Silicon) are measured by uniaxial tension test from freestanding SCS which are $2.5{\mu}m$ thick, $200-500{\mu}m$ wide specimens on the (100) plane. Young's modulus, Poisson's ratio and tensile strength in the <110> direction are measured by micro-tensile testing system.

  • PDF

MEMS 공정을 이용한 단결정 실리콘 미세 인장시편과 미세 변형 측정용 알루미늄 Marker의 제조 (Fabrication of Single Crystal Silicon Micro-Tensile Test Specimens and Thin Film Aluminum Markers for Measuring Tensile Strain Using MEMS Processes)

  • 박준식;전창성;박광범;윤대원;이형욱;이낙규;이상목;나경환;최현석
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.285-289
    • /
    • 2004
  • Micro tensile test specimens of thin film single crystal silicon for the most useful structural materials in MEMS (Micro Electro Mechanical System) devices were fabricated using SOI (Silicon-on-Insulator) wafers and MEMS processes. Dimensions of micro tensile test specimens were thickness of $7\mu\textrm{m}$, width of 50~$350\mu\textrm{m}$, and length of 2mm. Top and bottom silicon were etched using by deep RIE (Reactive Ion Etching). Thin film aluminum markers on testing region of specimens with width of $5\mu\textrm{m}$, lengths of 30~$180\mu\textrm{m}$ and thickness of 200 nm for measuring tensile strain were fabricated by aluminum wet etching method. Fabricated side wall angles of aluminum marker were about $45^{\circ}~50^{\circ}$. He-Ne laser with wavelength of 633nm was used for checking fringed patterns.

마이크로 터빈 개발 및 성능 평가 (Micro Turbine Development and Performance Test)

  • 전병선;제갈승;민홍석;방정환;김세준;송성진;주영창;민경덕
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.473-476
    • /
    • 2002
  • Micro turbine that is a component of micro power system refers to turbines on the scale of centimeters which can transmit power on the order of tens of Watts. Such devices can be used as propulsion or power generation devices for various potable and micro devices. An interdisciplinary team at Seoul National University has designed, fabricated and tested such a device, and this paper describes test results.

  • PDF

고인성 비조질강 샤시부품 개발 (Development of Chassis Parts Using High Toughness Micro-alloyed Steel)

  • 이시엽;김혁
    • 한국자동차공학회논문집
    • /
    • 제20권3호
    • /
    • pp.1-6
    • /
    • 2012
  • This paper developed the chassis part as micro-alloyed steel with high toughness. The performance of micro-alloy steels are superior to similar heat treated steels. The strengthening effects of vanadium make micro-alloyed steels particularly suited for high-strength-steel applications. The disadvantages are that ductility and toughness are not as good as quenched and tempered (Q&T) steels. Precipitation hardening increases strength but may contribute to brittleness. Toughness can be improved by reducing carbon content and titanium additions. dispersed titanium nitrides (TiN) formed by titanium additions effectively prevents grain coarsening. Grain refinement increases strength but also improves toughness. For the chassis parts using high toughness micro-alloy steel, it had proven superior to a plain steel forging by static strength test and endurance test.

Fabrication of Micro Spur Gear in Nano Grained Al Alloy

  • Lee, Won-Sik;Jang, Jin-Man;Ko, Se-Hyun
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.778-779
    • /
    • 2006
  • Manufacturing technologies of micro parts were studied in nano grained Al-1.5mass%Mg alloy. During compressive test at $300^{\circ}C$, the Al alloy showed stain softening phenomenon by grain boundary sliding regardless of strain rate. Micro spur gear with ten teeth (height of $200{\mu}m$ and pitch of $250{\mu}m$) was fabricated with sound shape by micro forging. During micro forging, increase of applied stress induced by friction between material and die surface was effectively compensated by decrease of stress by strain softening behavior and as a result, flow stress increased only about 50 MPa more than that in compressive test

  • PDF