• 제목/요약/키워드: Micro Pump

검색결과 186건 처리시간 0.024초

피에조마이크로펌프를 이용한 클라우드기반 수액주입기 (A Cloud-based Infusion Injector using Piezoelectric Micropump)

  • 송영진;강정구;송근산
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.62-65
    • /
    • 2018
  • We will provides a micro-pump infusion injector with the cloud networking for remote control. The existing infusion injector with controlled manually have an uncomfortable to use it inconveniently. The proposed remote control infusion, infusion system enables the identification and control of injected amount through the IOT function on th WEB. The micro-pump used is a piezo electric pump manufactured by using MEMS technology, and the amount of charge is varied depending on the frequency magnitude through the micro-controller. The micro-pump can adjust the speed of the fluid depending on the frequency and can be from 0.1ml / min to 7ml / min when the frequency is from 3 to 110Hz.

Temperature analysis of extra vessel electromagnetic pump cooling for a Micro nuclear reactor with an electric power of 20 MW

  • Tae Uk Kang;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.275-282
    • /
    • 2024
  • Lead bismuth eutectic (LBE) is used as coolant for MicroURANUS, a small marine nuclear power plant, and this coolant is transported in the plant by an electromagnetic pump. Given the considerable heat generated by the electromagnetic pump, the cooling of the pump is essential. This study compared air cooling and water-cooling methods and found that the maximum temperatures during air and water cooling were 640 K and 372 K, respectively. These findings were utilized to design an electromagnetic pump with water-cooling. The maximum temperature of the pump was lower than the boiling point of water; thus, the pump did not require a separate pressurization. Consequently, the resistance problem of the coil and the deformation problem of the material caused by generated heat can be solved through water-cooling.

미세기포 발생 펌프에서 생성되는 기포농도와 용존공기농도의 비교 (Comparison of Dissolved Air and Micro-Bubble Concentration by a Micro-Bubble Generating Pump)

  • 이창한;안갑환
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1835-1842
    • /
    • 2014
  • The goal of this study was to evaluate micro-bubble concentration ($C_{air}$) in water by air/water ratio (A/W ratio) with a micro-bubble generating pump. The estimation of micro-bubble concentration is based on the balance of inlet/outlet air and water flow rate. On net A/W ratio to be generated micro-bubble, we found that the obtained the $C_{air}$ are shown as a function of discharge pressure ($P_g$) of the micro-bubble generating pump. The correlation of the $C_{air}$ and the $P_g$ ($C_{air}=3.261P_g-1.754$) was adequately described by the least square methods with a high correlation coefficient (r = 0.9459) and calculated values fit the experimental data quite well. The $C_{air}$ was lower than theoretical dissolved air concentration ($C_{aq}$) calculated by Henry's law. The $C_{air}$ for being operated the micro-bubble generating pump was 6.75 - 39.53 mL/L, however, we found that the optimum of the $C_{air}$ to generate micro-bubble was the range from 10 to 12 mL/L.

Reynolds 수와 Knudsen 수가 초소형 점성펌프에 미치는 영향 (EFFECTS OF THE REYNOLDS AND KNUDSEN NUMBERS ON THE FLOW OF A MICRO-VISCOUS PUMP)

  • 강동진;이벨리나이바노바이바노바
    • 한국전산유체공학회지
    • /
    • 제13권2호
    • /
    • pp.14-19
    • /
    • 2008
  • Effects of the Reynolds and Knudsen numbers on a micro-viscous pump are studied by using a Navier-Stokes code based on a finite volume method. The micro viscous pump consists of a circular rotor and a two-dimensional channel. The channel walls are treated by using a slip velocity model. The Reynolds number is studied in the range of $0.1{\sim}50$. The Knudsen number varies from 0.01 to 0.1. Numerical solutions show that the pump works efficiently when two counter rotating vortices formed on both sides of the rotor have the same size and intensity. As the Reynolds number increases, the size and intensity of the vortex on the inlet side of the pump decrease. It disappears when the Reynolds number is larger than about Re=20. The characteristics of the performance of the pump is shown to deteriorate, in terms of mean velocity and pressure rise, as the Reynolds number increases. The Knudsen number shows a different effect on the characteristics of the pump. As it increases, the mean velocity and pressure rise decrease but the characteristics of the vortex flow remains unchanged, unlike the effect of Reynolds number.

레져버에 압력이 가해지는 환경에서의 미소 정량 토출 펌프의 개발 (Development of Constant Delivery Micro Pump in a Variable Pressure Environment for Intrathecal Drug Administration System)

  • 이태경;이철수;정유석;박경근
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.387-394
    • /
    • 2017
  • This paper develops a pump system for patient with chronic pain or cancer. The pump module is consists of two micro-valve and membrane. The micro-valve is operated by a solenoid. With two solenoid valves which are connected via a drug transport line, the inlet and outlet are completely blocked. A silicon rubber membrane located between the two valves makes the flow-rate constant without any backflow. This pump module can control the flow-rate of drugs by controlling the time that the valves are opened and closed. The reservoir consists of a drug chamber and a gas chamber. As the gas chamber encloses the drug chamber, propellant gas which is injected into the gas chamber pressurizes the drug chamber regardless of volume of the drug chamber. To design the pump module, analysis a constant efficiency test, and accuracy test for the pump module were conducted.

바이오용 압전디스크방식 마이크로 펌프 설계 및 제작(I) -링형 플랩밸브 모듈의 최적설계- (Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (I): Optimal Design of Ring-shaped Flab Valve Module)

  • 김형진;서영호;김병희
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.355-361
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, it has some intrinsic disadvantages such as backward flow, pulsation of flow, low repeatability and producibility, and high cost. To overcome these limitation, a PZT disc actuated micro pump including a novel ring-shaped multi-flap check valve is introduced. To enhance the performance of the micro pump, the static behaviour of flap valve module and the micro fluidic behavior of fluids are numerically modelled and analyzed. As results of the numerical analysis, the optimal dimension and configuration of the ring-shaped multi flap valve are $1{\times}0.05$ mm and 2 (inlet side)${\times}1$ (outlet side) type. The obtained maximum flow rates and flow resolution are about 90 ml/min and 30 ${\mu}l$/stroke respectively.

디스크형 진동자를 이용하는 새로운 형태의 밸브리스 마이크로 압전 펌프

  • 오진헌;임종남;정의환;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.91-91
    • /
    • 2009
  • Piezoelectric micro-pump should contain the physical running parts like check valves for acquiring the unilateral motion of fluid from the alternating motion of actuators. But the check valves raise many problems such as abrasion or exhaustive destruction by the recursive mechanical displacement To solve these problems, we propose a novle type piezoelectric valveless micro-pump using peristaltic motion due to the traveling wave excitation. Proposed pump model is consisted of two piezoelectric ceramic plates, elastic metal body, caps for covering flow path, rubber rings for sealing tightly and disk springs for the pressurization of pump body.

  • PDF

초소형 추진장치에 적용을 위한 누센펌프의 멤브레인 종류에 따른 질유량 특성 (Mass flow rate of Knudsen pump According to Membrane Type for Micro Propulsion Applications)

  • 김혜환;허환일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.36-40
    • /
    • 2008
  • 마이크로 추진장치에서 노즐의 소형화는 많은 유동손실을 유발한다. 이러한 유동손실을 극복하기 위해 본 연구에서는 열적발산원리를 이용한 새로운 개념의 마이크로 추진장치에 대한 기초연구를 진행하였다. 움직이는 부품 없이 오직 온도구배만으로 추진제를 낮은 온도에서 높은 온도로 자체 펌핑이 가능한 열적발산장치를 설계, 제작 하였으며, 진공환경에서 누센수에 따른 멤브레인 압력구배효율을 분석하였다. 또한 기존 누센펌프의 멤브레인인 폴리이미드와 종이재질의 전통 한지를 사용하여 질유량 특성을 비교하였다.

  • PDF

알루미늄 플랩 밸브와 상변화 구동 마이크로 펌프의 제작 (The fabrication of a micro pump with a flap valve and a phase change actuator)

  • 이상우;심우영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1023-1025
    • /
    • 1998
  • This paper presents the fabrication of a micro pump consisting of a pair of Al f1ap wave and a phase change actuator. The phase change actuator is composed of a heater, a silicone rubber diaphragm and a working liquid chamber. The diaphragm is actuated by the evaporation and the condensation of the working liquid. The actuator pumps fluid through the valves. The micro pump is fabricated by the anisotropic etch, the boron deposition and the metal evaporation. The forward and the backward flow characteristics of the f1ap valves were obtained. Also, the flow rate of the micro pump has been measured. When the square wave input of 12 V, 60% duty ratio and 0.2 Hz is applied, the average flow rate is $0.15{\mu}{\ell}/sec$ for zero pressure difference.

  • PDF