• Title/Summary/Keyword: Micro Motor

Search Result 350, Processing Time 0.03 seconds

Development of Chassis Parts Using High Toughness Micro-alloyed Steel (고인성 비조질강 샤시부품 개발)

  • Lee, Si-Yup;Kim, Hyuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.1-6
    • /
    • 2012
  • This paper developed the chassis part as micro-alloyed steel with high toughness. The performance of micro-alloy steels are superior to similar heat treated steels. The strengthening effects of vanadium make micro-alloyed steels particularly suited for high-strength-steel applications. The disadvantages are that ductility and toughness are not as good as quenched and tempered (Q&T) steels. Precipitation hardening increases strength but may contribute to brittleness. Toughness can be improved by reducing carbon content and titanium additions. dispersed titanium nitrides (TiN) formed by titanium additions effectively prevents grain coarsening. Grain refinement increases strength but also improves toughness. For the chassis parts using high toughness micro-alloy steel, it had proven superior to a plain steel forging by static strength test and endurance test.

Development of a Micro Tensile Tester for the Material Characterization and the Reliability Estimation of Micro Components (마이크로 부품의 물성 및 신뢰성 평가를 위한 시험기 개발)

  • 이낙규;최석우;임성주;최태훈;이형욱;나경환
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.2
    • /
    • pp.27-33
    • /
    • 2004
  • This paper is concerned with development of a micro tensile testing machine for optical functional materials such as single or poly crystal silicon and nickel film. Two micro tensile testers have been developed for various types of materials and dimensions. One of the testers is actuated by a PZT and the other is actuated by a servo motor for a precise displacement control. The specifications of PZT actuated micro tensile tester developed are as follows: the volumetric size of tester is desktop sized of 710$\times$200$\times$270 $mm^3$; the minimum load capacity and the load resolution in the load cell of 1N are 3 mN and 0.1 mN respectively; the full stroke and the stoke resolution of piezoelectric actuator are 1 mm and 10nm respectively. A special automatic specimen installing equipment is applied in order to prevent unexpected deformation and misalignment of specimens during handling of specimen for testing.

  • PDF

Design of an One-Chip Controller for an Electronic Dispenser (전자 디스펜서용 단일칩 제어기 설계)

  • Won, Young-Uk;Kim, Jeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.137-140
    • /
    • 2005
  • The electronic dispenser is composed of electronic part and mechanical part. Electronic part is consisted of input keypad, micro-controller, display module, and pump module. In this paper we designed micro-controller for electronic part. The micro-controller controls display module and pump module. The display module is composed by LCD device, and the pump module is composed by motor device. The micro-controller for an electronic dispenser is designed by VHDL. We used WX12864APl for the LCD device and SPS20 for the stepping motor. Also, the micro-controller is designed by Altera Quartus tool and verified with Agent 2000 Design-kit using APEX20K Device. In this paper, we present possibility to adopt of biotechnology field through designing of one-chip controller for an electronic dispenser.

  • PDF

A Micro Tribotester for MEMS Elements

  • Kim Choong-Hyun;Ahn Hyo-Sok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.4
    • /
    • pp.39-43
    • /
    • 2006
  • A computer-controlled micro tribotester has been developed to investigate the friction and wear characteristics of thin coatings, which can be applied to silicon-based materials. In the developed system, a step motor gives a reciprocating movement and an electromagnet applies a load between a ball and a plate specimen. Test results confirmed that the application of load in the range of $0.03{\sim}1.8N$ and with a sliding speed of $4.44{\sim}7.70mm/s$ was successfully accomplished. Advantages of the developed micro tribotester are: (1) realization of micro load and displacement applicable to micro electromechanical systems(MEMS) using DC motor and electromagnet (2) continuously variable load and reciprocating speed; and (3) high reliability, which allows for unattended use for long periods.

A Development of the Control System of BLDC Motor for Micro Motor Handpiece (마이크로 모터 핸드피스를 위한 BLDC 전동기 제어시스템 개발)

  • Baik, Won-Sik;Song, Hyun-Jig;Kim, Min-Huei;Kim, Dong-Hee;Lee, Heon-Uk;Hwang, Don-Ha
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.231-234
    • /
    • 2008
  • The permanent magnet BLDC motors are increasingly being used in high performance applications due to the high torque density and simplicity in their control. In this paper, the control system of the BLDC motor is developed which can be used for the micro motor handpiece, and position sensorless control is realized using back EMF measurement scheme, The validity and practical applications of the developed slotless BLDC motor and drive system are verified through the experimental results.

  • PDF

A Study On Chuck System development for PDP panel sealing process (PDP panel 봉입 공정을 위한 Chuck System 개발에 관한 연구)

  • 이재황;김희식;최기상;이호찬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.337-337
    • /
    • 2000
  • This paper describes a Chuck System developed for scaling PDP gas hole on PDP panel glass. There are lots of constraints for designing Chuck System: high temperature, high vacuum, precious motor control etc. A such constraints was considered by design of structure and by selecting of parts and material for Chuck System. The Chuck System was manufactured and assembled after the design process. It was applied on the PDP process unit. For sealing POP hole, precious control of a step motor was important in this system. For this experiment, a step motor, motor driver and micro controller(80196KC) were used.

  • PDF

Development of a Wheel Type Locomotive Mechanism Using Micro motor for a Capsule-Type Endoscope (모터를 이용한 바퀴형 체내이동 메커니즘의 개발)

  • Lee, Young-Jae;Kim, Byung-Kyu;Lim, Young-Mo;Park, Jong-Oh;Hong, Yeh-Sun;Kim, Soo-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.289-294
    • /
    • 2001
  • The two prototypes of a Wheel Type Locomotive Mechanism Using Micro motor for a Capsule-Type Endoscope are outlined and realized. Basic concept of these mechanisms is to use a rod-shaped wheel, with which these mechanisms can go over the haustral folds inside colon. The actuator of Prototype I is geared dc motor and the actuator for steering is Shape Memory Alloy. Prototype I goes through the whole area of colonoscopy training model. Prototype II can not only go forward and backward, but also be steerable with 2 geared dc motors. Prototype II goes through dead pig colon.

  • PDF

Ultra Precision Positining System for Servo Motor-piezo Actuator Using the Dual Servo Loop and Digital Filter Implementation (이중서보제어루프와 디지털 필터를 통한 서보모터-업전구동기의 초정밀위치결정 시스템 개발)

  • Lee, Dong-Sung;Park, Jong-Ho;Park, Heui-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.154-163
    • /
    • 1999
  • In this paper, an ultra precision positioning system has been developed using dual servo loop control. For positioning system having long distance with ultra precision , the combination of global stage and micro stage was required. A servo motor based ball screw is used as a global stage and the piezo actuator as a micro stage. For the improvement of positional precision, the digital Chebyshev filter is implemented in the developed to dual servo system. Therefore, the positional repeatability has been achieved within ${\pm}$ 10 mm, and this technique can be applied to develop precision semiconductor equipments such as lithography steppers and probers.

  • PDF

Micro-vibration Isolation Performance of X-band Antenna Using Blade Gear (블레이드 기어를 적용한 2축 짐발 구동 안테나의 미소진동 절연성능)

  • Jeon, Su-Hyeon;Kwon, Seong-Cheol;Kim, Tae-Hong;Kim, Yong-Hoon;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.5
    • /
    • pp.313-320
    • /
    • 2015
  • A 2-axis gimbal-type X-band antenna has been widely used to effectively transmit the high resolution image data from the observation satellite to the desired ground station. However, a discontinuous stepper motor activation for rotating the pointing mechanism in azimuth and elevation directions induces undesirable micro-vibration disturbances which can result in the image quality degradation of a high-resolution observation satellite. To enhance the image quality of the observation satellite, attenuating the micro-vibration induced by an activation of the stepper motor for rotational movements of the antenna is important task. In this study, we proposed a low-rotational-stiffness blade gear applied to the output shaft of the stepper motor to obtain the micro-vibration isolation performance. The design of the blade gear was performed through the structure analysis such that this gear is satisfied with the margin of safety rule under the derived torque budget. In addition, the micro-vibration isolation performance of the blade gear was verified through the micro-vibration measurement test using the dedicated micro-vibration measurement device proposed in this study.

Research on Development of a Wide Range Velocity Control Method of Small Size DC Motor for Portable Drug Delivery System

  • Lee, Dong-Joon;Lim, Yang-Ho;Kim, Jang-Hwan;Shin, Chan-Soo;Kim, Hee-Chan;Choi, Soo-Bong;Lee, Hong-Gyu
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.22-24
    • /
    • 1996
  • Small size DC motor control method for portable drug delivery system has been developed to be used for the actuator of insulins pump. The control method gives the controllabilities both in high speed(40-50 revolution per second(rps)) DC motor drive and also in low speed(0.5-1rps). In low speed mode DC motor is controlled to act like stepping motor and in high speed to optimize power consumption. To control both mode modified bang bang control is suggested. Using this method small size DC motor(spec.) speed is controlled from 0.2 rps to 50 rps. Experimental setup is developed using micro-processor(PIC16C73, Micro Chips co., USA), motor turns checking circuitry, small size DC motor for pager(SM1012, Samhong co., Korea) and gear box. Results from experiment meet need for vailable load condition which is require for portable drug delivery system.

  • PDF