• 제목/요약/키워드: Micro Fan

검색결과 56건 처리시간 0.028초

마이크로 팬의 최적 금형파팅면 생성에 관한 연구 (A Study on the Optimized Parting Surface Creation for a Micro Fan)

  • 최상련
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.245-250
    • /
    • 1999
  • In order to design micro-fan appropriately, flow chacracteristics and mechanics should be carefully considered. The present work concerns with design procedure for a micro-fan using NACA(National Advisory Committee for Aeronautics) airfoil series. The generation of fan profiles is carried out automatically by defining related parameters, which is also converted to CAD/CAM data automatically. The optimal parting surface for the mold of micro-fan is also calculated by analyzing the geometric data numerically. As a consequence, the high capacity micro-fan can be developed successfully with a high-quality and an improved efficiency.

  • PDF

축류 마이크로 홴의 전산해석 및 성능시험 (A Numerical Analysis and Experiment for Micro-Fans)

  • 조진수;변태균;박왕식;전창근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

CPU 냉각용 저소음 Micro-Cooling Fan 의 개발 (Development of Micro-Cooling Fans for Cooling of CPU)

  • 김기황;박용민;김진화;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.961-966
    • /
    • 2001
  • Micro fans of randomly swept-blades were designed to provide C.P.U. in a personal computer with effective cooling in a very quiet mode. The proto--type axial micro-fans machined by a laser sintering machine were tested against manufactured products by comparing the performance and overall sound pressure level with spectral measurements in an environment suggested by ASHRAE and ANSI standards. The predicted OSPLs and directivity patterns of fans by iDesignFan software were in good agreements with measured data. The newly introduced fans of randomly swept-blades were proved to provide a very promising mode of low noise at small loading conditions.

  • PDF

미세 다공판을 이용한 레인지 후드의 소음저감 (Noise Reduction of a Range Hood using Micro-Perforated Panel)

  • 김덕한;송화영;이동훈;이창근;김동윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1205-1208
    • /
    • 2006
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which rumbling noise is generated. Though the rumbling noise has low noise level. this noise makes most of the users nervous due to the its low frequency characteristics. For the purpose of noise reduction, in this study, a micro-perforated panel system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood is decreased over 2dB(A) in all frequency regions due to the effect of noise reduction by micro-perforated panel system.

  • PDF

홴 후방 유동장을 고려한 홴싱크 설계에 관한 연구 (A Study on the Design of a Fan-Sink Considering the Flow Fields Behind the Fan Outlet)

  • 조진수;한승호;한철희
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1055-1061
    • /
    • 2002
  • A numerical and experimental study on the flow fields behind the fan outlet was carried out to improve the performance of a conventional fan-sink(fan and heat sink). Conventional fan-sinks have a heat sink of which fin configurations tend to increase the flow resistance, thus decreasing the performance and the cooling capabilities of a fan-sink. Lifting surface method is used for the prediction of flow fields behind the fan outlet. Oil-dot flow visualization technique is applied for the validation of numerical results. The numerical results and experimental data show agreement each other. A conventional heat sink is modified and redesigned using flow patterns behind the fan outlet. The newly designed heat sink has the configuration of curved fins which minimize flow resistance. It showed improvements in both cooling: capabilities and volumetric flow rate compared to the conventional one.

레이저 3차원 진동측정기와 마이크로폰을 이용한 진공청소기용 팬모터의 실험적인 공력소음 분석 (The Experimental Analysis of Aerodynamic Sound for Fan Motor in a Vacuum Cleaner Using Laser 3-D Scanning Vibrometer and Microphone)

  • 곽이구;안재신;김재열
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.46-51
    • /
    • 2005
  • The vacuum cleaner motor runs at very high speed for suction power. Specially, motor power is provided by the impeller being rotated at very high speed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and small gap distance between the impeller and the diffuser, the level of noise in the centrifugal fan is at BPF(Blade Passage Frequency) and its harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, unsteady flow data are needed. The cause of noise is obtained by dividing the fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, an accelerometer has been used to measure vibration. However, it can not measure vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This study was conducted to perform accurate analysis of vibration and aerodynamic sound for fan motor in a vacuum cleaner using a laser vibration analyzer. A silent fan motor can be designed using the data measured in this study.

원심형 보조날개를 부착한 축류홴의 유동특성에 관한 실험적 연구 (An Experimental Study on the Flow Characteristics of Axial Flow Fan with Centrifugal Sub-Blade)

  • 이석종;성재용;이명호
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권3호
    • /
    • pp.19-25
    • /
    • 2013
  • A new type axial flow fan with centrifugal sub-blades has been designed and fabricated in the present study. We investigated velocity and pressure distributions in downstream flow fields of the fan experimentally to detect the detailed flow characteristics of new axial flow fan and an existing axial flow fan. Two-dimensional velocity components were probed by applying a particle image velocimetry system and pressure distributions were measured by Pitot tube and micro-manometer. Our results show that the velocity and pressure distributions at the flow fields of the new fan are quite different from the existing fan, and that the centrifugal sub-blades in the new fan can improve the performance characteristics in view of kinetic energy.

나노 템플레이트를 이용한 마이크로 히트 싱크 (Fabrication of Micro-Heatsink using Nanotemplate)

  • 함은주;손원일;홍재민
    • 마이크로전자및패키징학회지
    • /
    • 제10권1호
    • /
    • pp.7-11
    • /
    • 2003
  • 반도체 칩이나 전자제품에 사용되는 부품들은 작동할 때 발열을 하게 되며 발생한 열이 적절히 제거되지 않을 경우 제품 오작동의 원인이 된다. 이러한 열을 제거하기 위해 히트싱크(heatsink)와 냉각 팬 (cooling fan)을 조합한 냉각 구조가 사용된다. 그러나 히트싱크와 냉각 팬의 조합 구조는 복잡한 형상을 취하기 때문에 전기 전자 제품의 소형화 추세에 부응하기에는 어려움이 따른다. 냉각 효율은 히트싱크의 표면적과 히트싱크 제조시 사용된 재료에 따라 달라진다. 일반적인 냉각 구조의 한계를 극복하기 위한 방안으로써, Trach-etched 멤브레인의 표면과 기공(pore)에 무전해 금도금과 구리 도금을 실행하여 크기는 작으면서 표면적을 증가시킨 마이크로 히트싱크를 제조하였다. 제조한 마이크로 히트싱크의 구조는 주사현미경(SEM)과 광학 현미경으로 관찰하였으며, 일반적인 구리보다 열효율이 우수함을 방열 특성 실험을 통해 관찰하였다.

  • PDF

미세 다공판을 이용한 환기팬 시스템의 소음저감 (Noise Reduction of a Ventilating Fan System using Micro-Perforated Panel)

  • 이종석;송화영;이동훈;권혁정;김동윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1209-1211
    • /
    • 2006
  • This paper introduces an experimental study for the noise reduction of a ventilating fan system. For the purpose of noise reduction, conventionally an absorptive duct silencer filled with a glass fiber has been utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with its noise reduction performance.

  • PDF

Micro lens array 설계 (Design of micro lens array)

  • 홍경희
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.204-211
    • /
    • 1994
  • 팩시밀이나 복사기용으로 이용되는 micro lens array를 설계하였다. array 형태는 육각형배열이고 유효경은 0.160mm, 가장 가까운 이웃렌즈의 중심간 거리는 0.192mm로 하였다. 결상계의 횡배율은 1.0이다. single layer는 working distance가 10.55mm, double layer는 working distance가 7.90mm가 되었다. 각각의 성능은 ray fan을 계산하여 그 특성을 조사하였으며 서로 비교하였다.

  • PDF