• Title/Summary/Keyword: Micro Data Center

Search Result 209, Processing Time 0.023 seconds

Cluster ing for Analysis of Raman Hyper spectral Dental Data

  • Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • In this research, we presented an effective clustering method based on ICA for the analysis of huge Raman hyperspectral dental data. The hyperspectral dataset captured by HR800 micro Raman spectrometer at UMKC-CRISP(University of Missouri-Kansas City Center for Research on Interfacial Structure and Properties), has 569 local points. Each point has 1,005 hyperspectal dentin data. We compared the clustering effectiveness and the clustering time for the case of using all dataset directly and the cases of using the scores after PCA and ICA. As the result of experiment, the cases of using the scores after PCA and ICA showed, not only more detailed internal dentin information in the aspect of medical analysis, but also about 7~19 times much shorter processing times for clustering. ICA based approach also presented better performance than that of PCA, in terms of the detailed internal information of dentin and the clustering time. Therefore, we could confirm the effectiveness of ICA for the analysis of Raman hyperspectral dental data.

Toward Functional Genomics of Plant-Pathogen Interactions: Isolation and Analysis of Defense-related Genes of Rot Pepper Expressed During Resistance Against Pathogen

  • Park, Do-Il;Lee, Sang-Hyeob
    • The Plant Pathology Journal
    • /
    • v.18 no.2
    • /
    • pp.63-67
    • /
    • 2002
  • To understand plant-pathogen interactions, a complete set of hot pepper genes differentially expressed against pathogen attack was isolated. As an initial step, hundreds of differentially expressed cDNAS were isolated from hot pepper leaves showing non-host resistance against bacterial plant pathogens (Xanthomonas campestris pv. glycines and Pseudomonas syringae pv. syringae) using differential display reverse transcription polymerase chain reaction (DDDRT-PCR) technique. Reverse Northern and Northern blot analyses revealed that 50% of those genes were differentially expressed in pepper loaves during non-host resistance response. Among them, independent genes without redundancy were micro-arrayed for further analysis. Random EST sequence database were also generated from various CDNA libraries including pepper tissue specific libraries and leaves showing non-host hypersensitive response against X. campestris pv. glycines. As a primary stage, thousands of cDNA clones were sequenced and EST data were analyzed. These clones are being spotted on glass slide to study the expression profiling. Results of this study may further broaden knowledge on plant-pathogen interactions.

A variably compliable probe system for the in-circuit test of a PCB (인쇄회로기판의 통전검사를 위한 가변순응력을 갖는 프로브 시스템)

  • Shim, Jae-Hong;Cho, Hyung-Suck;Kim, Sung-Kwun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.323-331
    • /
    • 1997
  • A new probing mechanism and an active compliance control algorithm have been developed for the in-circuit test of a PCB( printed circuit board ). Commercially available robotic probing devices are incapable of controlling contact force generated through rigid probe contacts with a solder joint, at high speed. The uncontrollable excessive contact force often brungs about some defects on the surface of the solder joint, which is plastically deformable over some limited contact force. This force also makes unstable contact motions resulting in unreliable test data. To overcome these problems, we propose that a serially connected macro and micro device with active compliance provide the best potential for a safe and reliable in-circuit test. This paper describes the design characteristics, modeling and control scheme of the newly proposed device. The experimental results clearly show the effectiveness of the proposed system.

  • PDF

Fabrication of an Electrostatic Micro Actuator Using p+ Diaphragm As an Electrode (p+ 박막을 전극으로 한 정전형 마이크로 구동기의 제작)

  • Han, Sang-Woo;Yang, Eui-Hyeok;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.141-143
    • /
    • 1994
  • In this paper, an electrostatic micro-actuator is fabricated using flat p+ diaphragm. To avoid the buckling of the flat p+ diaphragm, the processes are designed appropriately. The fabrication processes of the actuator are the anisotropic etching with EPW, the boron diffusion process, Al deposition and the silicon to glass bonding using the negative photoresist. The distance between the p+ and Al electrodes is $10{\mu}m$, and the thickness of the p+ diaphragm is $2{\mu}m$. The measurement of the characteristic of the actuator is performed at 50V. The center displacement of the diaphragm is $1.5{\mu}m$ at 10Hz. In comparison with the experimental data of the actuator with corrugated diaphragm, it is confirmed that the actuator with flat diaphragm is more effective than that with corrugated one in the small deflection region.

  • PDF

Climatological Variability of Satellite-derived Sea Surface Temperature and Chlorophyll in the South Sea of Korea and East China Sea (남해와 동중국해에서 위성으로 추정된 표층수온 및 클로로필의 장기 변화)

  • Son, Young-Baek;Ryu, Joo-Hyung;Noh, Jae-Hoon;Ju, Se-Jong;Kim, Sang-Hyun
    • Ocean and Polar Research
    • /
    • v.34 no.2
    • /
    • pp.201-218
    • /
    • 2012
  • The purpose of this study is to investigate climatological variations from the sea surface temperature (SST), chlorophyll-a concentration (Chl-a), and phytoplankton size class (PSC), using NOAA AVHRR, SeaWiFS, and MODIS data in the South Sea of Korea (SSK) and East China Sea (ECS). 26-year monthly SST and 13-year monthly Chl-a and PSC data, separated by whole and nine-different areas, were used to understand seasonal and inter-annual variations. SST and Chl-a clearly showed seasonal variations: higher SST and Chl-a were observed during the summer and spring, and lower values occurred during the winter and summer. The annual and monthly SST over 26 years increased by $0.2{\sim}1.0^{\circ}C$. The annual and monthly Chl-a concentration over 13 years decreased by $0.2{\sim}1.1mg/m^3$. To determine more detailed spatial and temporal variations, we used the combined data with monthly SST, Chl-a, and PSC. Between 1998 and 2010, the inter-annual trend of Chl-a decreased, with decreasing micro- and nano-size plankton, and increasing pico-size plankton. In regional analysis, the west region of the study area was spatially and temporally correlated with the area dominated by decreasing micro-size plankton; while the east region was less sensitive to coastal and land effects, and was dominated by increasing pico-size plankton. This phenomenon is better related to one or more forcing factors: the increased stratification of ocean driven by changes occurring in spatial variations of the SST caused limited contributions of nutrients and changed marine ecosystems in the study area.

Evaluation of Acid Resistance of Demineralized Dentin after Silver Diamine Fluoride and Potassium Iodide Treatment (Silver Diamine Fluoride와 요오드화 칼륨 도포 후 변화하는 탈회 상아질의 내산성 평가)

  • Haesong, Kim;Juhyun, Lee;Siyoung, Lee;Haeni, Kim;Howon, Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.392-401
    • /
    • 2022
  • This study investigated the effects of silver diamine fluoride (SDF) and potassium iodide (KI) treatments on the acid resistance of dentin exposed to secondary caries. Sixteen bovine dentin specimens with artificially induced caries were assigned to the following four groups: untreated negative control, untreated positive control, SDF-treated (SDF), and SDF and KI-treated (SDFKI). Multispecies cariogenic biofilms containing Streptococcus mutans, Lactobacillus casei, and Candida albicans were cultured on the specimens for 28 days, except for the negative control group. Specimens from the negative control group were stored in phosphate-buffered saline for that period. After a cariogenic biofilm challenge, the degree of demineralization was evaluated using micro-computed tomography (micro-CT). As a result of data analysis using micro-CT, the demineralization depths of the negative control, positive control, SDF, and SDFKI groups were 149.0 ± 7 ㎛, 392.0 ± 11 ㎛, 206.0 ± 20 ㎛, and 230.0 ± 31 ㎛, respectively. The degree of demineralization was significantly reduced in the SDF and SDFKI groups compared with that in the untreated positive control group. There were no significant differences between the SDF and SDFKI groups. This study confirmed that SDF and SDFKI treatments increase the acid resistance of dentin to secondary caries. KI did not significantly affect the caries-arresting effect of the SDF.

Improvement Effect on Design Parameters by Pressure Grouting Applied on Micro-piling for Slope Reinforcement (가압식 마이크로파일로 보강된 사면의 설계인자 개량효과)

  • Hong, Won-Pyo;Han, Hyun-Hee;Choi, Yong-Ki;Hong, Ik-Pyo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.163-170
    • /
    • 2005
  • In this paper, the rock bolts, soil nails with filling grout and the micro-piling with injecting grout by pressure were applied for the stabilization of the cut slopes consisting of sedimentary rocks, igneous rocks and metamorphic rocks respectively. The field measurements and 3-D FEM analyses to find out mobilized tensile stresses of the grouted-reinforcing members installed in the drilled holes were executed on each site. With assuming the increments of the cohesive strength in the improved ground, the back analysis using direct calibration approach of changing the elastic modulus of the ground was used to find out the improved elastic modulus which yields the same tensile stresses from field measurements. The results of back analysis show that the elastic modulus of the improved ground were 4 to 6 times as large as the elastic modulus of original ground. Consequently, the design for slope reinforcement to be more rational, it is proposed that not only the improved cohesive strength is to be used in the incremental ranges on well-known previous proposed data, but also the increased elastic modulus which is about 5 times as large as the original elastic modulus is to be considered in design.

  • PDF

Characteristics of Copper Plating Solutions for Electroforming of Microcircuit (미세 배선 성형을 위한 전주용 동도금액의 특성)

  • Park, Hae-Deok;Jang, Do-Yeon;Gang, Seong-Gun
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.820-832
    • /
    • 2001
  • In order to obtain the basic data on the optimum conditions of electroforming process for fabricating the micro wiring pattern for plate type micro- motor core, characteristics of plating bath and properties of deposits were studied with various copper plating baths which contain sulfate, fluoborate, pyrophosphate and cyanide salt, respectively. Cathodic polarization, throwing power, internal stress, texture and surface morphology of deposits were observed. Throwing power of plating solution is deeply related to the polarization curves and the values are in the range of +20∼20%. The order of values ate as follows- pyrophosphate, cyanide, sulfate and fluoborate bath. Internal stresses of deposits are tensile in all of the copper plating bath. Thickness of the deposits plated at the center of holes has the highest value in the pyrophosphate bath and K factor, ratio of height and width of deposit, is 1.44. It was confirmed that the pyrophosphate bath was the best one for the electroforming of wire pattern.

  • PDF

Measurements of Adhesion Force of Micro-Sized Toner Particles Deposited on the Developing Roller Surface in a Non-contact type Laser Printer (비접촉 방식 레이저 프린터 현상롤러 위에 부착된 마이크로 토너 입자의 부착힘 측정)

  • Kim Sang-Yoon;Lee Dae-Young;Sheen Sowon;Eun Jong Moon;Hwang Jungho
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.75-80
    • /
    • 2005
  • Study for toner adhesion is known as an important role in electrophotography. In this research, a centrifugal detachment method was used to measure the adhesion force of several hundred particles simultaneously and to determine its sensitivity to particle size. For uncharged toner particles, we estimated the van der Waals force based on the centrifugal farce experiments. Then for charged toner particles, the centrifugal force experiments were carried out. The difference between the results for charged toner particles and the results for uncharged toner particles was compared with the image force calculated from a model which assumed that the toner charge was located at the center of the particle. In the calculations, experimental data obtained by E-SPART (Electrical- Single Particle Aerodynamic Relaxation Time) analyzer were used. The adhesion force of micro-sized toner particles deposited on the DR surface was found to be approximately 1${\~}$3 nN.

  • PDF

Measurements of Adhesion Force of Micro-Sized Toner Particles Deposited on the Developing Roller Surface in a Non-contact type Laser Printer (비접촉 방식 레이저 프린터 현상롤러 위에 부착된 마이크로 토너 입자의 부착힘 측정)

  • Kim, Sang-Yoon;Lee, Dae-Young;Sheen, So-Won;Eun, Jong-Moon;Hwang, Jung-Ho
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.105-110
    • /
    • 2006
  • Study for toner adhesion is 3non as an important role in electrophotography. In this research, a centrifugal detachment method was used to measure the adhesion force of several hundred particles simultaneously and to determine its sensitivity to particle size. For uncharged toner particles, we estimated the van der Waals force based on the centrifugal force experiments. Then for charged toner particles, the centrifugal force experiments were carried out. The difference between the results for charged toner particles and the results for uncharged toner particles was compared with the image force calculated from a model which assumed that the toner charge was located at the center of the particle. In the calculations, experimental data obtained by E-SPART (Electrical-Single Particle Aerodynamic Relaxation Time) analyzer were used. The adhesion force of micro-sized toner particles deposited on the DR surface was found to be approximately $1{\sim}3$ nN.

  • PDF