• 제목/요약/키워드: Micro Coil Spring

검색결과 15건 처리시간 0.026초

마이크로 코일 스프링의 스프링 상수 평가 (Evaluation of the Spring Constant of a Micro Coil Spring)

  • 이종길;전병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 2001
  • The spring constant of a micro coil spring was measured by uniaxial tensile test. The inner diameter of it is $35{\mu}m$ and the pitch size is about $23{\mu}m$. A suing constant measurement system was developed. It consists of control units, load cell units, linear stages and several specially designed jigs and fixtures. Load and displacement are measured using a commercial load cell of 1000g capacity and a magnetic scale of $0.5{\mu}m$ resolution. In this study, a method to measure the spring constant of micro coil spring is presented and the relationship between misalignment of specimen and measurement error is discussed.

  • PDF

유한요소 해석을 이용한 마이크로 스프링의 전단공정 개선에 관한 연구 (A Study on the Cutting Processes improvement of Micro-Spring by Finite Element Analysis)

  • 홍석관;전병희;김민건
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.421-426
    • /
    • 2003
  • Micro-suing that used on micro mechanism should be equal to distance between pitch and correct of shape. Therefore, micro spring must make by super-precision working. But, current step of super-precision processing depends on special quality of work piece and is ineffective the aspect of cost and productivity yet. Also, to use as demandable length shearing process perform but even if make precision spring, in the aspect of quality of coil spring make difficult that produce product of good quality. Therefore, purpose of this study presented proposed process that extract the point of processing factor after perform finite element analysis applying existing sheet shearing process to suing shearing process consider cost and productivity after evaluate.

  • PDF

진동 특성을 고려한 마이크로 엑추에이터 판 스프링의 최적설계 (Optimal Design of Micro Actuator Plate Spring Considering Vibration Characteristic)

  • 이종진;이호철;유정훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.220-225
    • /
    • 2003
  • Recent issue of optical actuator is applying to mobile device. It leads actuator to become smaller than conventional type. This paper proposes the design of micro actuator plate spring and analysis of its vibration characteristic. Considering natural frequency of spindle motor, 1st and 2nd eigenfrequency of micro actuator must avoid its natural frequency. First, magnetic circuit is designed by using fine pattern coil and magnetic force is acquired by simulation program. Then, concept design is achieved by topology optimization. From concept design, micro actuator plate spring is embodied through DOE(design of experiment). Finally, considering vibration characteristic simultaneously, optimal plate spring design is determined by RSM(response surface method).

  • PDF

저주파수 진동형 전자기식 마이크로 발전기의 설계 및 해석 (Design and Analyses of Vibration Driven Electromagnetic Energy Harvester with High Power Generation at Low Frequency)

  • 이병철;정귀상
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.102-106
    • /
    • 2011
  • This paper presents a design and analysis of an electromagnetic micro generator which can convert low frequency vibration energy to electrical power. The design aspects of the micro generator comprised planar spring, Cu coil and a permanent magnet(NdFeB). Threetype spring designs and four materials(Parylene, FR-4, Cu and Si) were compared to find resonance frequency. It was found that the resonance frequency will be changed according to the spring shape and material. Mechanical and magnetic parameters had been adjusted to optimize the output power through a comprehensive theoretical study.

지그재그 형태의 형상기억합금 스프링을 이용한 굽힘 액츄에이터의 제작 (Fabrication of Bending Actuator Using Zigzag-type Shape Memory Alloy Springs)

  • 임안수;이승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2512-2514
    • /
    • 1998
  • The bending actuator using zigzag type shape memory alloy springs has been fabricated and characterized. The small sized actuator with outer diameter of 3.0mm and inner diameter of 2.0mm could be implemented because zigzag type spring has advantages for thin wall type actuator over the coil type spring. The measured characteristics of the fabricated bending actuator show the possibility of practical application to micro active bending catheter.

  • PDF

Design of a VCM actuator for dual servo system

  • Choi, Hyeun-Seok;Han, Chang-Soo;Kim, Seung-Soo;Kim, Eung-Zu;Choi, Tae-Hoon;Na, Kyoung-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.301-306
    • /
    • 2004
  • In this study, Dual servo mechanism with VCM(Voice Coil Motor) and PZT is designed for a high precision force and position control. We designed the VCM actuator and dual servo mechanism with leaf spring. VCM actuators, with their high linearity, simple structure, low weight, and high efficiency, are increasingly being used in micro-positioning applications. There are many kinds of VCM with a structure. VCM actuators are divided into two types by moving parts. One is moving magnet type and the other moving coil type. We described the properties of these two types of VCM. Design parameters of VCM are defined through the FEM simulation analysis of magnetic field and dynamic model of dual servo mechanism. These researches help to for decreasing loss in the air gap of VCM. We present dual servo mechanism is effective mechanism for a force control in hi h precision, properties of designed VCM.

  • PDF

지그재그 형태의 형상기억합금 스프링을 이용한 굽힘 액추에이터의 제작 (Fabrication of Bending Actuator using Zigzag-type Shape Memory Alloy Spring)

  • 임안수;이승기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.269-274
    • /
    • 1999
  • A bending actuator using zigzag type shape memory alloy springs has been fabricated and characterized. The fabricated millimeter-sized actuator has outer diameter of 3.0mm and inner diameter of 2.0mm. The zigzag type spring is more suitable for thin wall type actuator because the zigzag type spring has a planar structure comparing with the coil type spring which has a three-dimensional structure. The measured characteristics of the fabricated bending actuator show the possibility of practical application to micro active bending catheters.

  • PDF

위상-치수 최적화에 의한 마이크로 구동기 판 스프링의 설계 (Plate Spring Design of a Micro Actuator Using Topology-parameter Optimization)

  • 이종진;이호철;유정훈
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1246-1253
    • /
    • 2007
  • The recent issue of optical pickup actuators is to apply optical storage devices to mobile devices such as a cellular phone and PDA. It requires actuators to become smaller than conventional types. As the size becomes smaller, the magnetic force is reduced and the assembly of optical pickup actuators becomes more difficult. In addition, its dynamic characteristics are changed. In this paper, methods to improve magnetic forces and dynamic characteristics are suggested and the optimal result of the plate spring design is obtained. A diamond shape magnet and the fine pattern coil (FPC) are used to improve magnetic forces and damping elements are attached to decrease the peak magnitude of the mode instead of using structural damping, mostly for the purpose of improving the accuracy of the finite element simulation. To get more stable dynamic characteristics than conventional ones, a plate spring is applied to the optical pickup actuator and it is optimized with topology and parameter optimization to obtain the concept and the detail design, respectively.

고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구 (Effects of drilling process in stability of micro-implants used for the orthodontic anchorage)

  • 장영일;김종완
    • 대한치과교정학회지
    • /
    • 제32권2호통권91호
    • /
    • pp.107-115
    • /
    • 2002
  • 본 연구는 교정적 고정원을 얻기 위하여 micro-implant(Osas$^{(R)}$, Epoch medical)를 drill method와 drill-free method로 매식시, 조기 교정력에 대한 각각의 경우 micro-implant의 역학적 안정성 및 조직학적 생체 적합도의 차이를 알아보고자 시행하였다. 두 마리의 실험견(beagle dog)을 대상으로 상, 하악 협측과 구개부위에 좌우측을 구분하여 drill method 군과drill-free method 군으로 나누어 매식하였다. 매식 한 재료는 직경 1.6 mm의 micro-implant를 사용하였으며, drill method 군 16개, drill-free method 군 16개, 총32개의 micro-implant를 식립하였다. 교정력은 매식 후 1주 뒤에 Ni-Ti coil spring(Ni-Ti springs-extension$^{(R)}$, Ormco)으로 200 gm - 300 gm의 힘을 적용하였다. 동요도 검사는 희생 전에 Periotest$^{(R)}$(Siemens)로 측정하였다. 매식 12주 후에 관류고정 하였으며 시편은 레진 포매하여 Exakt system$^{(R)}$(Exakt)을 이용하여 비탈회 표본을 제작하였다. 표본은 H-E 염색한 뒤, 광학 현미경 상에서 검경하여 조직학적 소견을 분석하였고 조직계측학적 측정은 골접촉률과 골밀도로 분석하였다. 위와 같은 실험을 통하여 매식한 micro-implant의 탈락률과 동요도, 골접촉률 및 골밀도로 drill method 군과 drill-free method 군의 역학적 안정성 및 조직학적 생체 적합도를 비교, 분석한 결과 다음과 같은 결론을 얻었다. 1. micro-implant와 골의 계면은 기계적 접촉 뿐만 아니라 골유착도 있었다. 2. micro-implant의 탈락은 drill method 군이 더 높았다. 3. 동요도는 drill method 군이 전반적으로 더 컸다. 4. micro-implant와 골접촉 정도는 전반적으로 drill-free method 군에서 양호했다. 5. micro-implant 나사산 사이 내에 존재하는 골밀도는 전반적으로 drill-free method 군에서 더 높았다. 결론적으로, micro-implant는 매식시 drill-free method가 drill method보다 탈락률과 동요도 및 골접촉률과, 골밀도에서 더 우수한 결과를 보여 drilling 과정이 안정성과 골조직 치유 및 골유착에 영향을 미친다고 판단된다.

Design of Torsion-typed Smooth Picture Actuator for DLP Projection TV

  • Moon, Yang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.564-568
    • /
    • 2006
  • Smooth picture module is operated by vibration to tilt the light from the DMD (digital micro mirror device) of DLP projection TV, which makes the screen of the TV smoother and DMD chip cost lower. To satisfy the vibration characteristics of smooth picture module, it is designed by optimizing moment of inertia, spring constant and damping coefficient, using structural and fluid dynamic simulation that showed a good agreement with experimental data. To reduce the material cost and moment of inertia, engineering plastic is used and the reliability is estimated. A VCM (voice coil motor) type actuator for smooth picture has to satisfy performance requirements such as higher driving force, lower power consumption, and lower cost. The initial design and optimization for VCM was performed using FE analysis. It allowed us to optimize the design of magnetic circuit of the proposed actuator to obtain higher force while maintaining a lower cost.

  • PDF