• Title/Summary/Keyword: Micro Bead

Search Result 61, Processing Time 0.041 seconds

Study on Hindered Diffusion of Single Polyelectrolyte Chain in Micro-Pores by Employing Brownian Dynamics Simulations (브라운 동력학 시뮬레이션에 의한 미세기공에서 단일한 다가전해질 사슬의 제한확산 연구)

  • 전명석;곽현욱
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.207-215
    • /
    • 2002
  • The hindered diffusion in confined spaces is an important phenomenon to understand in a micro-scale the filtration mechanism determined by the particle motion in membrane pores. Compared to the case of spherical colloids, both the theoretical investigations and the experiments on the hindered diffusion of polyelectrolytes is actually more difficult, due to lots of relevant parameters resulting from the complicated conformational properties of the polyelectrolyte chain. We have successfully performed the Brownian dynamics simulations upon a single polyeiectrolyte confined in a slit-like pore, where a coarse-grained bead-spring model incorporated with Debye-Huckel interaction is properly adopted. For the given sizes of both the polyelectrolyte and the pore width, the hindered diffusion coefficient decreases as the solution ionic concentration decreases. It is evident that a charge effect of the pore wall enhances the hindered diffusion of polyelectrolyte. Simulation results allow us to make sense of the diffusive transport through the micro-pore, which is restricted by the influences of the steric hindrance of polyelectrolytes as well as the electrostatic repulsion between the polyelectrolytes and pore wall.

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channel and GMR-SV Device

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Khajidmaa, Purevdorj;Bolormaa, Munkhbat;Lee, Sang-Suk
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2015.05a
    • /
    • pp.161-163
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of RBC + ${\mu}Beads$ is controlled by the electrical AC input signal. The RBC + ${\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

  • PDF

Microstructures of Friction Stir Lap Weld in A5052-H112 Alloy (A5052-H112 합금의 겹치기 마찰교반접합 조직 특성)

  • Ko, Young-Bong;Lee, Joong-Hun;Park, Kyeung-Chae
    • Journal of Welding and Joining
    • /
    • v.27 no.6
    • /
    • pp.17-24
    • /
    • 2009
  • The Friction Stir Welding(FSW) has mainly been used for making butt joints in Al alloys. Development of Friction Stir Lap Welding(FSLW) would expand the number of applications. Microstructure of FSLW in A5052-H112 alloy was investigated under varying rotation and welding speed. As the rotation speed was increased and the welding speed was decreased, a amount of heat was increased. As a result, bead interval was narrower, bead width are larger, and experimental bead interval was almost similar to theoretical bead interval. Typical microstructures of FSLW A5052-H112 alloy consist of three zones, including Stir Zone(SZ), Thermo-Mechanically Affected Zone(TMAZ) and Heat Affected Zone(HAZ). As a amount of heat was increased, average grain size was larger in three zones. Nevertheless, the aspect ratio was almost fixed for FSLW conditions. The misorientation of SZ, HAZ and TMAZ was examined. A large number of low angle grain boundaries, which were formed by severe plastic deformation, were showed in TMAZ as comparison with SZ and HAZ. Microhardness distribution was high in order of BM, SZ, TMAZ, and HAZ. The Micro-hardness distribution in HAZ, TMAZ of upper plate were lager than lower plate. Relationship between average grain size and microhardness was almost corresponded to Hall-Petch equation.

BEAD BASED CHEMICAL REACTION SYSTEM USING TEMPERATURE AND FLUID CONTROL FOR CANCER DETECTION (유체와 온도 조절을 이용한 생화학 물질 반응용 마이크로칩의 개발)

  • Kim, Min-Su;Lee, Bo-Rahm;Yoon, Hyo-Jin;Kim, Byung-Gee;Lee, Yoon-Sik;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1466-1467
    • /
    • 2008
  • We describe here a novel micro total analysis system for the purification and identification of the affinity-captured proteins. Also we demonstrated the mass analysis of the Carcinoembrionic antigen (CEA) and Alpha femtoprotein which were chosen as the target cancer marker. For MALDI-TOF analyses, the proteins should to be separated from a protein mixture and be concentrated when needed. This procedure usually takes a long time even before protease-digested samples are to be obtained from them. Here, we describe integrated and efficient micro chip for protein purification and digestion for MALDI-TOF analyses. At first, disease protein is purified by passing the micro chamber from a protein mixture or human whole serum and released from the micro affinity beads by thermal heating. Purified protein is then transfer to the hole for trypsin digestion. The final sample is analyzed by MALDI-TOF. All the processes could be finished successfully within one hour, which renders MALDI-TOF analyses of a target protein quite simple.

  • PDF

Welding Characteristic of Super Alloys for Nd:YAG Laser (Nd:YAG 레이저를 이용한 초합금 소재의 용접 특성 연구)

  • Yu, Sang-Hyeon;Lee, Je-Hun;Seo, Jeong;Kim, Jeong-O;Lee, Yeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.158-160
    • /
    • 2006
  • Super alloys are typically used for the liquid thruster in the aerospace industry. In this work, The bead-on-plate welding of Inconel 600, Inconel 625 and Haynes 230 using Nd:YAG laser are studied, in order to examine the effects of experimental parameters on their weldability. The micro-hardness and tensile strength of the specimens are also analyzed, to obtain the optimal welding conditions.

  • PDF

Seam Welding of Amorphous Metal with Nd:YAG laser (Nd:YAG 레이저를 이용한 비정질재료의 심(seam) 용접)

  • 이건상
    • Laser Solutions
    • /
    • v.3 no.2
    • /
    • pp.45-51
    • /
    • 2000
  • In this paper, the possibilities and the limits of the laser seam welding were studied to utilize the advantageous properties of amorphous metal foils. For the conventional welding method, the high heat transfer makes the crystallized zone of the work material unavoidable. The laser is able to weld the amorphous metal without a crystallized zone, because heat transfer is limited within a very small restricted volume. The crystallized zone is restricted in the neighbor of welding spot and not in the melting area. This can be proved directly by the etching and indirectly by the tensile shear test, micro hardness test and bending test. The overlapping of welding bead could form the formation of wider and thicker amorphous zone.

  • PDF

A study for PP resin High magnification MCPs Extrusion foaming (MCPs 압출 공법을 이용한 PP 수지의 고배율 압출 발포 연구)

  • Hyun C.H.;Cha S.W.;Kim H.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1046-1050
    • /
    • 2005
  • Micro Cellular Plastics create a sensation at polymer industrial for lowering product cost & overcoming a lowering of mechanical intensity. There Is much development from injection molding pans but Extrusion parts is slow. This research is MCPs Extrusion parts, It is basis experiment for Process to make beads that is basis raw material of Package used most by shock mitigative of industry.

  • PDF

Microfilter Chip Fabrication for Bead-Based Immunoassay (비드를 이용한 면역분석용 마이크로필터 칩의 제작)

  • Lee, Seung-Woo;Ahn, Yoo-Min;Chai, Young-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1429-1434
    • /
    • 2004
  • Immunoassay is one of the important analytical methods for clinical diagnoses and biochemical studies, but needs a long time, troublesome procedures and expensive reagents. In this study, therefore, we propose the micro filter chip with microbeads for immunoassay, which has pillar structures. The advantage of the proposed micro filter chip is to use simple fabrication process and cheap materials. The mold was made by the photolithography technique with Si wafer and negative photoresist SU-8. The replica was made of PDMS, bonded on the pyrex glass. The micro filter chip consists of inlet channel, filter chamber and outlet channel. HBV (Hepatitius B virus) monoclonal antibody (Ag1) labeled with biotin were immobilized onto streptavidin coated beads of 30∼50 $\mu$m size. Fluorescein isothiocyanate (FITC)-labeled HBV monoclonal antibody (Ag8) was used to detect HBsAg (Hebatitis B virus surface Antigen), and fluorescence intensity was monitored by epi-fluorescence microscope. In this study, the immune response of less than 30 min was obtained with with the use of 100 $m\ell$ of sample.

Micro Pre-concentration and Separation of Metal Ions Using Microchip Column Packed with Magnetic Particles Immobilized by Aminobenzyl Ethylenediaminetetraacetic Acid

  • Kim, Y.H.;Kim, G.Y.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.905-909
    • /
    • 2010
  • Magnetic beads (Dynabeads$^{(R)}$) embedded in ~1 micron size polystyrene beads bearing surface carboxylic acid groups were modified with aminobenzyl ethylenediaminetetraacetic acid (ABEDTA) to concentrate or separate metal ions using pH gradients on micro and nano scales. The immobilization of ABEDTA was achieved by amide formation. The presence of the metal chelating functional group in the fully deprotonated form was confirmed by FT-IR. The chelation efficiency of beads was tested by determining metal ions in supernatant using GFAAS when pH gradients from 3 to 7. Mixtures of Cu and Mg and of Cd and Mn (at 10 ng/mL of metal) were separated as the difference in formation constant with the functional group of ABEDTA. The separation was repeated twice with relative standard deviation of <18%. A polydimethylsiloxane (PDMS) microchip column packed with EDTA-coated magnetic beads was optimized to concentrate metal ion for practical applications by eluting a Cu solution of micro scale at pH 3.