• Title/Summary/Keyword: Micro:bit

Search Result 211, Processing Time 0.031 seconds

Measurements of a microchannel flow using micro-PIV

  • Lee Inwon;Choi Jayho;Lee In-Seop
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.44-52
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.8\;\times\;6.8{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

Implemantation of Micro-Web Server Using ARM Processor and Linux (ARM 프로세서와 LINUX를 이용한 마이크로 웹서버 구현)

  • Lee, Dong-Hoon;Han, Kyong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.697-700
    • /
    • 2002
  • In this paper, we proposed the micro web-server Implementation on Strong ARM processor with embedded Linux. The parallel port connecting parallel I/O is controlled via HPPT protocol and web browser program. HTTP protocol is ported into Linux and the micro web server program and port control program are installed on-board memory using CGI to be accessed by web browser, such as Internet Explore and Netscape. 8bit LED and DIP switches are connected to the processor port and the switch input status is monitored and the LED output is controlled from remote hosts vie internet. The result of the proposed embedded micro-web server can be used in automation systems, remote distributed control via internet using web browser.

  • PDF

Experimental Investigation on Flow Characteristics of Chicken Blood in a Micro Tube Using a Micro-PIV Technique (마이크로 PIV를 이용한 미세튜브 내부 조류 혈액유동에 관한 실험적 연구)

  • Yeo, Chang-Sub;Ji, Ho-Seong;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1027-1034
    • /
    • 2006
  • In order to investigate flow characteristics of chicken blood in a micro tube of 100$\mu$m in diameter, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, 2-head Nd:YAG laser, 12 bit cooled CCD camera and a delay generator. Chicken blood with 40% hematocrit was supplied into a micro tube using a syringe pump. The blood flow shows clearly the cell free layer near the tube wall and its thickness is increased with increasing the flow speed. The hemorheological characteristics of chicken blood, including shear rate and shear stress were estimated from the PIV velocity field data obtained. Since the aggregation index of chicken blood is less than 50% of human blood, non-Newtonian flow characteristics of chicken blood are smaller than those of human blood. As the flow rate increases, the degree of flatness in the velocity profile at the center region is decreased and the parabola-shaped shear stress distribution becomes to have a linear profile. Under the same flow rate, chicken blood shows higher shear stress, compared with human blood.

A Study on 16/32 bit Bi-length Instruction Set Computer 32 bit Micro Processor (16/32비트 길이 명령어를 갖는 32비트 마이크로 프로세서에 관한 연구)

  • Cho, Gyoung-Youn
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.2
    • /
    • pp.520-528
    • /
    • 2000
  • he speed of microprocessor getting faster, the data transfer width between the microprocessor and the memory becomes a critical part to limit the system performance. So the study of the computer architecture with the high code density is cmerged. In this paper, a tentative Bi-Length Instruction Set Computer(BISC) that consists of 16 bit and 32 bit length instructions is proposed as the high code density 32 bit microprocessor architecture. The 32 bit BISC has 16 general purpose registers and two kinds of instructions due to the length of offset and the size of immediate operand. The proposed 32 bit BISC is implemented by FPGA, and all of its functions are tested and verified at 1.8432MHz. And the cross assembler, the cross C/C++ compiler and the instruction simulator of the 32 bit BISC are designed and verified. This paper also proves that the code density of 32 bit BISC is much higher than the one of traditional architecture, it accounts for 130~220% of RISC and 130~140% of CISC. As a consequence, the BISC is suitable for the next generation computer architecture because it needs less data transfer width. And its small memory requirement offers that it could be useful for the embedded microprocessor.

  • PDF

HPC(High Performance Computer) Linux Clustering for UltraSPARC(64bit-RISC processor) (UltraSPARC(64bit-RISC processor)을 위한 고성능 컴퓨터 리눅스 클러스터링)

  • 김기영;조영록;장종권
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.45-48
    • /
    • 2003
  • We can easily buy network system for high performance micro-processor, progress computer architecture is caused of high bandwidth and low delay time. Coupling PC-based commodity technology with distributed computing methodologies provides an important advance in the development of single-user dedicated systems. Lately Network is joined PC or workstation by computers of high performance and low cost. Than it make intensive that Cluster system is resembled supercomputer. Unix, Linux, BSD, NT(Windows series) can use Cluster system OS(operating system). I'm chosen linux gain low cost, high performance and open technical documentation. This paper is benchmark performance of Beowulf clustering by UltraSPARC-1K(64bit-RISC processor). Benchmark tools use MPI(Message Passing Interface) and NetPIPE. Beowulf is a class of experimental parallel workstations developed to evaluate and characterize the design space of this new operating point in price-performance.

  • PDF

Development of a Hydraulic Servo System Real-Time Simulator Using a One-board Microprocessor and Personal Computer (원보드 마이크로 프로세서 제어기 및 PC를 이용한 유압서보시스템의 실시간 시뮬레이터 개발)

  • Chang, Sung-Ouk;Lee, Jin-Kul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.94-99
    • /
    • 2000
  • In this study applied the general controller into th 16bit ordinary controller and recommand the simulator features the real system's propeties without DSP(Digital Signal Processing)-card. This simulator is designed to be synchronized in real time using A/D(Analog-Digital) convert and D/A(Digital-Analong) convert. In this study DSP card which is usually used for complex calculation is replaced with personal computer and designed to control, control-force using with the 16-bit micro processor.

  • PDF

(A) Study on Natural Dyeing of polyester(I) - Ginseng Microcapsules - (폴리에스테르의 천연염색 처리 방법에 관한 연구(I) - 인삼 마이크로캡슐을 중심으로 -)

  • Min, Kyung-Hae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.4
    • /
    • pp.560-565
    • /
    • 2008
  • Plantae of the natural material has been broadly used on cloth dyeing by it's specific properties such as eco-friendly and innoxious. However dyeing with natural material on synthetic fiber is nearly impossible due to poor affinity between natural material and synthetic fiber. The method which is binding with micro-capsulized natural material to cloth, used in this study, has low change on quality by external influence. Also this method has high ability in spray effect by broken capsule which comes to pressure and friction when the treated cloth was dressed. And this method is applicable widely from natural fiber to synthetic fiber. The purpose of this study is to develop the multi-functional synthetic material with micro-capsulized Ginseng on PET. Moreover, it was driven by comparison of colormetric properties and fastness between regular dip-dyeing method and binding with micro-capsulized material method. Dyeability showed a little bit low exhaustion but the PET treated by micro-capsule was more or less better than the dip dyed PET. Through the SEM(Scanning Electron Microscope) of PET treated by micro-capsule, it has good residence of capsules even after 5 or 10 times washing. Wash and light fastness were revealed some different grades by each condition but showed high level, in most and the micro-capsulized PET was more improver than regular dip dyed PET.

A Basic Study on Micro-Electric Potential accompanied with Specimen Failure during Uniaxial Compressive Test (일축 압축에 의한 시료 파괴 시 수반되는 미소 전위에 대한 기초 연구)

  • Kim, Jong-Wook;Park, Sam-Gyu;Song, Young-Soo;Sung, Nak-Hun;Kim, Jung-Ho;Cho, Seong-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.203-210
    • /
    • 2007
  • As a part of basic studies on monitoring of landslides and slope stability using SP measurements, micro-electric potentials of rock samples were measured accompanied with the rock failure by a uniaxial loading test were measured. The measurement system consists of a 8 channel A/D converter with 24 bit resolution, uniaxial loading tester, strain gages and 4 sets of electrode attached to a rock sample. Rock samples of granite, limestone, and sandstone were tested. Also, mortar samples were tested in order to monitor electric-potentials of a uniform sample. Micro-electric potentials were detected in all saturated samples and the strength of them increased as the loading force increased. Sandstone samples showed the largest strength of micro-electric potential and it followed limestone and granite samples, which indicates a positive relationship with porosity of rocks. The mechanism generating these micro-electric potential can be explained in terms of electro-kinetics. In case of dry samples, micro-electric potential could be observed only in sandstone samples, where piezoelectric effect played main role due to high contents of quartz in sandstone samples. We found that biggest micro-electric potentials were observed at the electrodes near the crack surface of rock samples. This is very encouraging result that SP monitoring can be applied to predicting landsliding or to estimate collapsing position combining with monitoring of acoustic emissions.

A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer (Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究))

  • Suh, W.M.;Min, Y.B.;Yoon, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF