• Title/Summary/Keyword: Metric for evaluation

Search Result 275, Processing Time 0.026 seconds

No-Touch Radiofrequency Ablation Using Twin Cooled Wet Electrodes for Recurrent Hepatocellular Carcinoma Following Locoregional Treatments

  • Seong Jun Hong;Jae Hyun Kim;Jeong Hee Yoon;Jeong Hoan Park;Jung-Hwan Yoon;Yoon Jun Kim;Su Jong Yu;Eun Ju Cho;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.438-448
    • /
    • 2024
  • Objective: To evaluate the therapeutic outcomes of no-touch radiofrequency ablation (NT-RFA) using twin cooled wet (TCW) electrodes in patients experiencing recurrent hepatocellular carcinoma (HCC) after undergoing locoregional treatments. Materials and Methods: We conducted a prospective, single-arm study of NT-RFA involving 102 patients, with a total of 112 recurrent HCCs (each ≤ 3 cm). NT-RFA with TCW electrodes was implemented under the guidance of ultrasonography (US)-MR/CT fusion imaging. If NT-RFA application proved technically challenging, conversion to conventional tumor puncture RFA was permitted. The primary metric for evaluation was the mid-term cumulative incidence of local tumor progression (LTP) observed post-RFA. Cumulative LTP rates were estimated using the Kaplan-Meier method. Multivariable Cox proportional hazard regression was used to explore factors associated with LTP. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat (ITT; including all patients) and per-protocol (PP; including patients not requiring conversion to conventional RFA alone) analyses were performed. Results: Conversion from NT-RFA to conventional RFA was necessary for 24 (21.4%) out of 112 tumors. Successful treatment was noted in 111 (99.1%) out of them. No major complications were reported among the patients. According to ITT analysis, the estimated cumulative incidences of LTP were 1.9%, 6.0%, and 6.0% at 1, 2, and 3 years post-RFA, respectively. In PP analysis, the cumulative incidence of LTP was 0.0%, 1.3%, and 1.3% at 1, 2, and 3 years, respectively. The number of previous locoregional HCC treatments (adjusted hazard ratio [aHR], 1.265 per 1 treatment increase; P = 0.004), total bilirubin (aHR, 7.477 per 1 mg/dL increase; P = 0.012), and safety margin ≤ 5 mm (aHR, 9.029; P = 0.016) were independently associated with LTP in ITT analysis. Conclusion: NT-RFA using TCW electrodes is a safe and effective treatment for recurrent HCC, with 6.0% (ITT analysis) and 1.3% (PP analysis) cumulative incidence of LTP at 2 and 3-year follow-ups.

Development and Application of Landscape Diversity Evaluation Model on the Basis of Rural and Natural Area (농촌 및 자연지역의 경관 다양성 평가모형 개발 및 적용)

  • Ra, Jung-Hwa;Lee, Yong-Eun;Cho, Hyun-Ju;Ku, Ji-Na;Kwon, Oh-Sung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.84-95
    • /
    • 2013
  • Recently, to prevent damage to the landscape, outstanding landscape areas have been designated in advance. In particular, as a fundamental way to evaluate landscape elements, landscape diversity is an important criterion to assess an area with a high conservative value. Therefore, the purpose of this study is to develop a quantitative evaluation model of landscape diversity based on landscape elements and to verify the model by applying it to the study sites. The assessment indicators derived from the literature analysis are topography, vegetation, land-use pattern, and unusual landscape. Topography diversity is subdivided into land undulation and land-form. Vegetation diversity is subdivided into plant community diversity and stratification diversity. To quantitatively analyse each indicator's diversity, SHDI was selected as the central metric. All of the quantitative measures were implemented by using the statistical tool, FRAGSTATS. Through the process of each indicator's standardization and summary, the final landscape diversity index was calculated. The results of the study are significant as it was the initial study of landscape diversity evaluation to seek applicability. However, the results of the Landscape Diversity Evaluation Model in this study based on 4 indicators synthetically demonstrate that more than one or two outstanding indicators can be underrated. Therefore, each 4 assessment indicator results should be considered individually. Furthermore, using the maximum value for each indicator's standardization reflects that it is necessary to analyse various examples to obtain higher objectivity later.

Semantic Segmentation of Clouds Using Multi-Branch Neural Architecture Search (멀티 브랜치 네트워크 구조 탐색을 사용한 구름 영역 분할)

  • Chi Yoon Jeong;Kyeong Deok Moon;Mooseop Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.143-156
    • /
    • 2023
  • To precisely and reliably analyze the contents of the satellite imagery, recognizing the clouds which are the obstacle to gathering the useful information is essential. In recent times, deep learning yielded satisfactory results in various tasks, so many studies using deep neural networks have been conducted to improve the performance of cloud detection. However, existing methods for cloud detection have the limitation on increasing the performance due to the adopting the network models for semantic image segmentation without modification. To tackle this problem, we introduced the multi-branch neural architecture search to find optimal network structure for cloud detection. Additionally, the proposed method adopts the soft intersection over union (IoU) as loss function to mitigate the disagreement between the loss function and the evaluation metric and uses the various data augmentation methods. The experiments are conducted using the cloud detection dataset acquired by Arirang-3/3A satellite imagery. The experimental results showed that the proposed network which are searched network architecture using cloud dataset is 4% higher than the existing network model which are searched network structure using urban street scenes with regard to the IoU. Also, the experimental results showed that the soft IoU exhibits the best performance on cloud detection among the various loss functions. When comparing the proposed method with the state-of-the-art (SOTA) models in the field of semantic segmentation, the proposed method showed better performance than the SOTA models with regard to the mean IoU and overall accuracy.

Availability Evaluation For Generation Orthoimage Using Photogrammetric UAV System (사진측량용 UAV 시스템을 이용한 정사영상 제작 및 활용성 평가)

  • Shin, Dongyoon;Han, Jihye;Jin, Yujin;Park, Jaeyoung;Jeong, Hohyun
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.3
    • /
    • pp.275-285
    • /
    • 2016
  • This study analyzes the accuracy of ortho imagery based on whether camera calibration performed or not, using an unmanned aerial vehicle which equipped smart camera. Photgrammetric UAV system application was developed and smart camera performed image triangulation, and then created image as ortho imagery. Image triangulation was performed depending on whether interior orientation (IO) parameters were considered or not, which determined at the camera calibration phase. As a result of the camera calibration, RMS error appeared 0.57 pixel, which is more accurate compared to the result of the previous study using non-metric camera. When IO parameters were considered in static experiment, the triangulation resulted in 2 pixel or less (RMSE), which is at least 200 % higher than when IO parameters were not considered. After generate ortho imagery, the accuracy is 89% higher when camera calibration are considered than when they are not considered. Therefore, smart camera has high potential to use as a payload for UAV system and is expected to be equipped on the current UAV system to function directly or indirectly.

Comparison of Personalized Ad Methods on the Internet and Smart Phone Platforms (인터넷과 스마트폰 환경에서의 개인화된 광고 방법론의 비교 분석)

  • Kim, Jun San;Lee, Jae Kyu
    • Asia pacific journal of information systems
    • /
    • v.22 no.4
    • /
    • pp.125-149
    • /
    • 2012
  • As the smart phone is propagating rapidly, the importance of mobile advertisement has also grown. One of the main characteristics of the Internet and smart phone advertising is that they can deliver personalized advertisements to each customer. The smart phone enables the identification of additional personalized information such as the customer's location and the accessibility to the site at any place any time. As the Internet platform becomes richer, firms that offer the ad services via the wired PC Internet and wireless smart phone are seeking various types of personalized ads. However, their service platform and Information and Communication Technology (ICT) platform should be suitable to the characteristics of personalized ads. This research explores various types of personalized ad methods and evaluates their adequacy encompassing four types of ad service platforms (such as search portal, news portal, e-mall servers, and SNS) and two types of ICT platforms (PC Internet and smart phone). To this end, we classified the personalized ads into seven types: three basic types and four composite types. The basic types of ad methods are identified by considering the current activity that the customer is engaged, the individual profile and log history, and the customer's current location or planning location. Four composite types of ad methods are constructed as the combination of these basic types. For those types of ad methods, we evaluate whether each ad method adequately maps with four types of ad service platforms and two types of ICT platforms. We proposed a metric of evaluation and demonstrated the concept with illustrative numbers. Specifically, we analyze and compare personalized ad methods in three ways. Firstly, the possibility of implementing a personalized ad method on the platform is analyzed to confirm the degree of suitability. Secondly, the value of personalized ad method is analyzed based on the customer accessibility. Lastly, expected effectiveness for each personalized ad method is computed by multiplying the possibility and the value. Through this kind of analysis, the ad service providers as well as advertising companies can evaluate what kinds of personalized ad methods and platforms are possible and suitable to maximize their ad effectiveness on the Internet and smart phone platforms.

  • PDF

Analysis of Ecological Health Using a Water Quality and Fish in Bocheong Stream (보청천의 수질 및 어류를 이용한 생태학적 건강도 분석)

  • Ryu, Tae-Ho;Kim, Yu-Pyo;Kim, Jin-Kyu;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.255-262
    • /
    • 2010
  • This study was conducted at 5 sites of Bocheong Stream basin in May and September 2009 for the evaluate of fish assemblage and chemical water quality. For the study, the models of Index of Biological Integrity (IBI) and Qualitative Habitat Evaluation Index (QHEI) were modified as 8 and 11 metric attributes, respectively. We also analyzed patterns of chemical water quality at the sampling site over the period of 2005~2009, using the water chemistry dataset, obtained from the Ministry of Environment, Korea. The survey showed that total sampled fishes were 34 species and the most dominant species was Zacco platypus (24.3%). In Bocheong Stream basin, values of IBI averaged 28 (n=5), which is judged as a "Good". IBI score at B1, B4 and B5 indicating a "Good" condition whereas, B2 and B3 were as 21 and 22, indicating "Fair" condition, respectively. QHEI was 152 (n=5), judged as "Fair" habitat condition. Values of BOD and COD averaged 1.0 $mgL^{-1}$ (scope: 0.3~4.0 $mgL^{-1}$) and 2.3 $mgL^{-1}$ (scope: 0.3~18.7 $mgL^{-1}$), respectively. Total nitrogen (TN), total phosphorus (TP) and suspended solid (SS) were distinct spatial variation. Based on the IBI, QHEI and chemical water quality dataset, ecological health of Bocheong Stream basin was evaluated that generally good.

A BERGPT-chatbot for mitigating negative emotions

  • Song, Yun-Gyeong;Jung, Kyung-Min;Lee, Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.12
    • /
    • pp.53-59
    • /
    • 2021
  • In this paper, we propose a BERGPT-chatbot, a domestic AI chatbot that can alleviate negative emotions based on text input such as 'Replika'. We made BERGPT-chatbot into a chatbot capable of mitigating negative emotions by pipelined two models, KR-BERT and KoGPT2-chatbot. We applied a creative method of giving emotions to unrefined everyday datasets through KR-BERT, and learning additional datasets through KoGPT2-chatbot. The development background of BERGPT-chatbot is as follows. Currently, the number of people with depression is increasing all over the world. This phenomenon is emerging as a more serious problem due to COVID-19, which causes people to increase long-term indoor living or limit interpersonal relationships. Overseas artificial intelligence chatbots aimed at relieving negative emotions or taking care of mental health care, have increased in use due to the pandemic. In Korea, Psychological diagnosis chatbots similar to those of overseas cases are being operated. However, as the domestic chatbot is a system that outputs a button-based answer rather than a text input-based answer, when compared to overseas chatbots, domestic chatbots remain at a low level of diagnosing human psychology. Therefore, we proposed a chatbot that helps mitigating negative emotions through BERGPT-chatbot. Finally, we compared BERGPT-chatbot and KoGPT2-chatbot through 'Perplexity', an internal evaluation metric for evaluating language models, and showed the superity of BERGPT-chatbot.

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Consideration of the Usefulness of 18F-FET Brain PET/CT in Brain Tumor Diagnosis (뇌종양진단에 있어 18F-FET Brain PET/CT의 유용성에 대한 고찰)

  • Kyu-Ho Yeon; Jae-Kwang Ryu
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.41-47
    • /
    • 2024
  • Purpose: 18F-FET, a radiopharmaceutical based on a Tyrosine amino acid derivative using the Sodium-Potassium Pump-independent Transporter (System L) for non-invasive evaluation of primary, recurrent, and metastatic brain tumors, exhibits distinct characteristics. Unlike the widely absorbed 18F-FDG in both tumor and normal brain tissues, 18F-FET demonstrates specific uptake only in tumor tissue while almost negligible uptake in normal brain tissue. This study aims to compare and evaluate the usefulness of 18F-FDG and 18F-FET Brain PET/CT quantitative analysis in brain tumor diagnosis. Materials and Methods: In 46 patients diagnosed with brain gliomas (High Grade: 34, Low Grade: 12), Brain PET/CT scans were performed at 40 minutes after 18F-FDG injection and at 20 minutes (early) and 80 minutes (delay) after 18F-FET injection. SUVmax and SUVpeak of tumor areas corresponding to MRI images were measured in each scan, and the SUVmax-to-SUVpeak ratio, an indicator of tumor prognosis, was calculated. Differences in SUVmax, SUVpeak, and SUVmax-to-SUVpeak ratio between 18F-FDG and 18F-FET early/delay scans were statistically verified using SPSS (ver.28) package program. Results: SUVmax values were 3.72±1.36 for 18F-FDG, 4.59±1.55 for 18F-FET early, and 4.12±1.36 for 18F-FET delay scans. The highest SUVmax was observed in 18F-FET early scans, particularly in HG tumors (4.85±1.44), showing a slightly more significant difference (P<0.0001). SUVpeak values were 3.33±1.13 for 18F-FDG, 3.04±1.11 for 18F-FET early, and 2.80±0.96 for 18F-FET delay scans. The highest SUVpeak was in 18F-FDG scans, while the lowest was in 18F-FET delay scans, with a more significant difference in HG tumors (P<0.001). SUVmax-to-SUVpeak ratio values were 1.11±0.09 for 18F-FDG, 1.54±0.22 for 18F-FET early, and 1.48±0.17 for 18F-FET delay scans. This ratio was higher in 18F-FET scans for both HG and LG tumors (P<0.0001), but there was no statistically significant difference between 18F-FET early and delay scans. Conclusion: This study confirms the usefulness of early and delay scans in 18F-FET Brain PET/CT examinations, particularly demonstrating the changes in objective quantitative metrics such as SUVmax, SUVpeak, and introducing the SUVmax-to-SUVpeak ratio as a new evaluation metric based on the degree of tumor malignancy. This is expected to further contributions to the quantitative analysis of Brain PET/CT images.

The Result of the Arthroscopic Reconstruction of Posterior Cruciate Ligament with Autogenous or Allogenous Graft (자가 또는 동종 이식물을 이용한 후방 십자 인대 재건술 후의 결과)

  • Chon Je-Gyun;Kim Eui-Soon;Choi Bo-Yeul;Yoon Chang-Hoon;Lee Jeong-Woung;Sun Doo-Hoon;Moon Myung-Sang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.74-79
    • /
    • 2001
  • Purpose : The purpose of this study is to evaluate the clinical results after arthroscopic PCL reconstruction and to compare the clinical results after arthroscopic PCL reconstruction using BPTB(bone patellar tendon bone) autograft(Group I : 11 cases), Achilles tendon allograft(Group II : 7 cases) and BPTB allograft(Group 111.6 cases). Materials and Methods : We reviewed the result of 24 patients who had been managed with arthroscopic reconstruction using different graft materials such as BPTB autograft, Achilles tendon allograft and BPTB allograft. Twenty-four patients(average age, 37 years) with PCL rupture were retrospectively evaluated more than one year(average, 31 months) after having arthroscopic posterior cruciate ligament reconstruction. The clinical results were evaluated by IKDC ligament standard evaluation form, using $KT-2000^{TM}$ knee ligament arthrometer and also evaluated Lysholm knee scoring scale. Results : The final evaluation was nearly normal in 11 patients($45\%$ in Group I, $43\%$ in Group II, $50\%$ in Group III). The corrected posterior sagging was abnormal(side to side difference more than 6mm) in 8 patients($36\%$ in Group I, $29\%$ in Group II, $33\%$ in Group III). We could not find significant difference among three groups by IKDC scale. Conclusion : Comparing with other reports, our overall results were not satisfactory. And also, we could not find any remarkable difference among the three groups. Further research is necessary to evaluate new surgical approaches as well as improved techniques for capsular and collateral ligament injuries.

  • PDF