A Case Study on Malfunction of OCGR and Inaccuracy of Watt-hour Meter in Distributed Generation System (분산형 발전고객의 OCGR오동작 및 과부족 계량에 대한 사례연구)

  • Shin, Dong-Yeol;Park, Yong-Woo;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1349-1355
    • /
    • 2008
  • The paper shows the analysis of operating conflict of OCGR trip events and metering errors in the photovoltaic generation, wind generation distributed generation customers with no defect of the distributed generation facilities, which are connected to 22.9kV distribution lines. To analyze problems with metering errors and OCGR fault event, a power quality analyzer and PSIM program were used to test the field and to simulate in Sun-Cheon photovoltaic generation and Seo-Cheon photovoltaic generation customers. With the trial distribution line, the result of analysis was verified to prove with the same situation of the actual field. This paper suggests short term and long term countermeasures of OCGR fault events, analysis of over and shortage of metering errors in distributed generation customers.

An Efficient WWW Metering Scheme based on Hash Functions (해쉬함수 기반의 효율적인 WWW 사용량 측정 방안)

  • Shin, Weon;Rhee, Kyung-Hyune
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.2
    • /
    • pp.133-139
    • /
    • 2000
  • In this paper we propose a secure and an efficient metering scheme for measuring the usage and the popularity of web pages. The proposed scheme is based on the cryptographic secure hash functions. Since the metering schemes based on cryptographic technology provides security, efficiency, accuracy and anonymity comparing to the existing metering schemes in WWW, they have the advantages that are secure against attempts by servers who inflate the number of clients and against attempt of collaboration of severs and clients.

  • PDF

Development of a Garlic Clove Planter Attached to Power Tiller (경운기 부착형 점파식 마늘파종기 개발)

  • Choi, D.K.;Park, S.H.;Kang, T.G.;Kwak, T.Y.;Lee, C.S.;Cho, S.C.;Kim, Y.J.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.140-146
    • /
    • 2009
  • The garlic, along with the red pepper, is one of the major seasoning vegetables in Korea. Garlic clove planting is one of the most laborious operations. Labor cost is the main source of high production cost of the garlic. Because of the geometrical uniqueness and irregularity of garlic cloves, mechanization of garlic clove planting is very difficult. To overcome price competition against the imported garlic, however, there has been a need of development of a clove metering device and a planting device for the garlic clove planter. Computer simulation, laboratory tests and field tests were conducted to develop a garlic clove planter. This research was conducted to drop garlic cloves into a soil holes through a drum bucket metering system and a rotary type planting system. Followings are the major achievements from this study. 1. The metering device consisted of a drum, a guide, a bucket and a bucket cover. Opening positions of the metering hopper were evaluated at different positions and trajectories of planting hoppers. The simulation showed that the optimum positions of hopper was -15${\sim}$0 mm in the x direction. 2. When the planter was tested under different soil textures and water contents, the best performances were obtained in a upland field with 29.1% water content and a paddy field with 18.3% water content where single clove metering and missing rate were 88.4% and 1.3%, and 90.7% and 2.0%, respectively.

An Empirical Research on the IoT Basis Gas AMI Platform and Smart Metering Services (IoT 기반 가스 원격검침(AMI) 플랫폼과 서비스의 실증 연구)

  • Lee, Seungwoo;Lee, Sangshin;Song, Min-hwan;Kwon, Youngmin
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.3
    • /
    • pp.1-10
    • /
    • 2020
  • This paper describes the development of a smart advanced metering infrastructure(AMI) architecture and services for using smart metering in gas industry. A general gas AMI system is composed of a smart gas meter, IoT network, the AMI platform, and an operation management system with security functions. The proposed gas AMI platform supports two-way communication between smart metering devices and AMI services and is applied by oneM2M standard to support interoperability between various types of metering devices and heterogeneous IoT networks. To demonstrating AMI system with the proposed platform, we installed about 2,900 smart gas meters in real environments and operated AMI systems for one year. We verified that about 94% of gas meters are normally worked and AMI services are stably operated without error or malfunction.

A Study on the Operation Boundary of Ramp Metering System (진입제어 전략 적용 시 적정 운영영역 설정에 관한 연구)

  • Kim, Kyu-Ok;Park, Joon-Hyeong;Park, Ji-Eun;Shin, Hee-Cheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.2
    • /
    • pp.9-21
    • /
    • 2011
  • The ramp metering strategy is one of the effective ways to solve the freeway traffic congestion in peak time periods. The study was initiated with assurance that the traffic conditions of ramp and mainline that mitigate the congestion would exist. Under the moderate traffic volume levels, ramp metering is expected to improve the quality of freeway operation. To derive a range of traffic condition, three operation strategies(Do nothing, ramp metering, minimum ramp control) were set up and the ALINEA algorithm was implemented with microscopic traffic simulator "VISSIM". The volumes of mainline and ramp are key parameters for the simulation scenarios. Measures of effectiveness for the study include mainline density and average vehicle speed. Operation boundaries in terms of traffic volume were proposed for operating ramp metering strategy. The results show that under the proposed traffic conditions the ramp metering was more successful to increase average vehicle speeds. Traffic controls under the operation boundaries of traffic levels give significant effects for density and average vehicle speed. The outcomes of this study would be useful to improve the performance of ramp metering strategies.

The Study on the Design Factors of the Groove-Roller Seed Metering Device for Seeder of Foxtail millet & Sorghum

  • Choi, Il Su;Kang, Na Rae;Kim, Young Keun;Jun, Hyeon Jong;Choi, Yong;Kang, Tae Gyoung;Hyun, Chang Sik;Lee, Sang Hee;Kim, Jin Gu;Yu, Seoung Hwa;Chung, Sun Ok
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.303-310
    • /
    • 2018
  • Purpose: This research was conducted to determine the design factors of a seed-metering device for the development of a seeder. The device allows the seeder to sow precisely one to three seeds of foxtail millet and sorghum. To obtain fundamental information regarding the design of the seed-metering device, examination of the physical properties of foxtail millet and sorghum was conducted. Methods: Based on the results of an adaptability test using an existing seeder with foxtail millet and sorghum, an experimental roller-type seed-metering device was made. The seeding factors considered during the experiment were the width, length, and depth, as well as the shape of the groove in the seed-metering roller. By adapting an analysis of variance, the experimental results of the seeding factors were analyzed. Results: The measured results of the respective lengths and widths of the seeds were 2.11 and 1.64 mm for foxtail millet, and 3.68 and 3.32 mm for sorghum, respectively. The weight of 1,000 seeds was 2.43 g for foxtail millet and 17.5 g for sorghum. The seeds were of an elliptical shape, considering the length and width. A sieve analysis showed that the size distribution of foxtail millet was quite regular whereas that of sorghum was irregular. Conclusions: The seeding results showed that the rates of incorrect planting were low when the groove of the roller-type metering device is an elliptical type. To sow one to three seeds, the groove of roller-type metering devices $2.0mm{\times}4.0mm{\times}1.5mm$ ($width{\times}length{\times}depth$) for foxtail millet, and $4.0mm{\times}8.0mm{\times}3.0mm$ and $4.5mm{\times}8.0mm{\times}3.0mm$ ($width{\times}length{\times}depth$) for Sorghum.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF