AMI Network Failure Analysis based on Graph Database (그래프 데이터베이스 기반 AMI 네트워크 장애 분석)

  • Jeong, Woo-Cheol;Jun, Moon-Seog;Choi, Do-Hyeon
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.7
    • /
    • pp.41-48
    • /
    • 2020
  • Recently, the spreading business of AMI (Advanced Metering Infrastructure) remote metering systems in various regions of the country has been activated, and it provides various metering functions such as two-way communication and security plan functions for power demand management. Current AMI system is difficult to analyze based on the existing RDB(Relational Database) due to the increase in the size of new internal IoT devices and networks. This study proposes a new GDB(Graph Database) based failure analysis method that utilizes existing RDB data. It analyzes the correlation of new failure patterns through accumulated data such as internal thresholds and status values. As a result of GDB-based simulation, it was confirmed that RDB can predict to a new obstacle pattern that was difficult to analyze.

Development of the Train Dwell Time Model : Metering Strategy to Control Passenger Flows in the Congested Platform (승강장 혼잡관리를 위한 열차의 정차시간 예측모형)

  • KIM, Hyun;Lee, Seon-Ha;LIM, Guk-Hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.3
    • /
    • pp.15-27
    • /
    • 2017
  • In general, increasing train dwell time leads to increasing train service frequency, and it in turn contributes to increasing the congestion level of train and platform. Therefore, the studies on train dwell time have received growing attention in the perspective of scheduling train operation. This study develops a prediction model of train dwell time to enable train operators to mitigate platform congestion by metering passenger inflow at platform gate with respect to platform congestion levels in real-time. To estimate the prediction model, three types of independent variables were applied: number of passengers to get into train, number of passengers to get out of trains, and train weights, which are collectable in real-time. The explanatory power of the estimated model was 0.809, and all of the dependent variables were statistically significant at the 99%. As a result, this model can be available for the basis of on-time train service through platform gate metering, which is a strategy to manage passenger inflow at the platform.

Research Regard to Necessity of Smart Water Management Based on IoT Technology (IoT 기술을 활용한 스마트 물관리 필요성에 관한 연구)

  • Choi, Young Hwan;Kim, Yeong Real
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.4
    • /
    • pp.11-18
    • /
    • 2017
  • The Objective of this Study is to Prove the Effectiveness of a Smart Water Management(SWM) Technology. The SWM Technology can Reduce the Production Cost using Internet of Thing(IoT) Technology that Utilizes Remote Metering of Consumer's Water usage and Reduce the Leakage of Supply Facilities. The SWM Demonstration Model Installed a Remote Water Leakage Sensor, Smart Metering and Micro Multi Sensor in Water Supply Facility, and Provided Real-Time Monitoring of the Operation Status. Consumers can be Provided the usage of Tap Water and the Water Puality through a Smart Phone Application. At this Time, we Surveyed Whether Consumers save the Tap Water or Drinking Directly using the Tap Water usage Information. Also, this Study is to Verify the Degree of Improvement of Water Supply Rates and Drinking Water Rate, and to Decrease Consumer's Complaints, Operating Costs, and Water Consumption by the SWM Technology. It is also Established a SWM Model Combined with the IoT Sensor at Supply Facilities, operator monitoring system and explored recovery solution detected events. It means the upbringing of the domestic water industry by developing the related technologies and spreading the SWM to advanced levels.

A Proposal of the Usage Metering Functions on Cloud Computing-Based Building Information Modeling (BIM) and the Law for the Open BIM Ecosystem (열린 BIM 생태계 조성을 위한 클라우드 컴퓨팅 기반 BIM 서비스 환경의 사용량 측정 기술 및 법 규정 제안)

  • Kim, Byungkon;Kim, Jongsung
    • Journal of KIBIM
    • /
    • v.6 no.3
    • /
    • pp.49-56
    • /
    • 2016
  • As project opportunities for the Architecture, Engineering and Construction (AEC) industry have grown more complex and larger, the utilization of Building Information Modeling (BIM) technologies for three-dimensional (3D) design and simulation practices has been increasing significantly; the typical applications of the BIM technologies include clash detection and design alternative based on 3D planning, which have been expanded over to the technology of construction management in the AEC industry for virtual design and construction. As for now, commercial BIM software has been operated under a single-user environment, which is why initial costs for its introduction are very high. Cloud computing, one of the most promising next-generation Internet technologies, enables simple Internet devices to use services and resources provided with BIM software. Recently in Korea, studies to link between BIM and cloud computing technologies have been directed toward saving costs to build BIM-related infrastructure, and providing various BIM services for small- and medium-sized enterprises (SMEs). This study addressed development of the usage metering functions of BIM software under cloud computing architecture in order to archive and use BIM data and create an optimal revenue structure so that the BIM services may grow spontaneously, considering a demand for cloud resources. For the reason, we surveyed relevant cases, and then analyzed needs and requirements from AEC industry. Based on the relevant cases, customizing for cloud BIM and design for the development was performed. We also surveyed any related-law to support cloud computing-based BIM service. Finally, we proposed herein how to optimally design and develop the usage metering functions of cloud BIM software.

Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway (도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Jongyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

Evaluation Of LoRaWAN In A Highly Dense Environment With Design Of Common Automated Metering Platform (CAMP) Based On LoRaWAN Protocol

  • Paul, Timothy D;Rathinasabapathy, Vimalathithan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.5
    • /
    • pp.1540-1560
    • /
    • 2022
  • Latest technological innovation in the development of compact lower power radios has led to the explosion of Internet of Things. With Wi-Fi, Zigbee and other physical layer protocols offering short coverage area there was a need for a RF protocol that had a larger coverage area with low power consumption. LoRa offers Long Range with lower power consumption. LoRa offers point to point and point to multipoint connections. with Single hop communication in place the need for routing protocols are eliminated. LoRa Wide Area Network stack can accommodate thousands of nodes under a single LoRa gateway with a single hop communication between the end nodes and LoRaWAN gateway. This paper takes an experimental approach to analyze the basic physical layer parameters of LoRa and the practical coverage offered by a LoRaWAN under highly dense urban conditions with variable topography. The insights gained from the practical deployment of the LoRaWAN network, and the subsequent performance analysis is used to design a novel public utility monitoring platform. The second half of the papers is designing a robust platform to integrate both existing wired sensor water meters, current and future generation wireless water meters. The Common Automated Metering Platform is designed to integrate both wired sensors and wireless (LoRaWAN and Wi-Fi) supported water meters. This integrated platform reduces the number of nodes under each LoRaWAN gateway and thus improves the scalability of the network. This architecture is currently designed to accommodate one utility application but can be modified to integrate multi-utility applications.

470-MHz-698-MHz IEEE 802.15.4m Compliant RF CMOS Transceiver

  • Seo, Youngho;Lee, Seungsik;Kim, Changwan
    • ETRI Journal
    • /
    • v.40 no.2
    • /
    • pp.167-179
    • /
    • 2018
  • This paper proposes an IEEE 802.15.4m compliant TV white-space orthogonal frequency-division multiplexing (TVWS)-(OFDM) radio frequency (RF) transceiver that can be adopted in advanced metering infrastructures, universal remote controllers, smart factories, consumer electronics, and other areas. The proposed TVWS-OFDM RF transceiver consists of a receiver, a transmitter, a 25% duty-cycle local oscillator generator, and a delta-sigma fractional-N phase-locked loop. In the TV band from 470 MHz to 698 MHz, the highly linear RF transmitter protects the occupied TV signals, and the high-Q filtering RF receiver is tolerable to in-band interferers as strong as -20 dBm at a 3-MHz offset. The proposed TVWS-OFDM RF transceiver is fabricated using a $0.13-{\mu}m$ CMOS process, and consumes 47 mA in the Tx mode and 35 mA in the Rx mode. The fabricated chip shows a Tx average power of 0 dBm with an error-vector-magnitude of < 3%, and a sensitivity level of -103 dBm with a packet-error-rate of < 3%. Using the implemented TVWS-OFDM modules, a public demonstration of electricity metering was successfully carried out.

A Study on Energy Saving of IMV Circuit using Pressure Feedback

  • Park, Hyoung Gyu;Nahian, Syed Abu;Anh, Kyoung Kwan
    • Journal of Drive and Control
    • /
    • v.13 no.4
    • /
    • pp.31-44
    • /
    • 2016
  • In recent hydraulic actuation systems, conventional hydraulic spool valves with pressure compensators are becoming less popular, after the introduction of the independent metering concept for valves. Within this concept, four valves are needed for actuating a single cylinder. Subsequently, this increases the freedom of controlling both chamber pressures of the cylinder, and it then provides for electronically-controlled pressure compensation facilities. Additionally, this has the potential to save valuable energy. The primary focus of this paper is to develop a new generation of hydraulic circuits using the independent metering valve (IMV). This configuration can function well as a conventional IMV circuit while providing better pressure control. We first describe the working principles of five distinct modes of the proposed IMV system. Then, mathematical models for each working mode are presented. Finally, we present numerical simulations that have been carried out to evaluate the system performance, in comparison with that of the conventional IMV configuration. The simulation results demonstrate that the performance of the new IMV configuration is superior to the conventional IMV system in terms of energy savings.

Development of Automatic Meter Reading and Meter Data Management System for Advanced Metering Infrastructure (첨단계랑인프라를 위한 원격검침 및 계량데이터관리 시스템 개발)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.829-836
    • /
    • 2017
  • This paper is a study on development of a new structured AMR/AMI(automatic meter reading/advance metering infrastructure) system. The developed system has a faster reading and is cheaper and easier to install compared to the existing AMR/AMI system. The system can be applied to AMR/AMI for five kinds of meters, electricity, gas, water, hot-water and calorie meter, which are used in most Korean households. Test results show that the developed system is both economical and reliable both in theoretical and practical applications. The resuts also show that the developed system is more suitable than existing system for AMR/AMI applications.

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (III) - Analysis of Pneumatic Conveying System and Improvement of Fertilizer Application Uniformity - (친환경 정밀농업을 위한 입제 변량살포기 개발 (III) -공기이송 시스템 분석과 입제 살포균등도 향상-)

  • Kim, Y.J.;Kim, H.J.;Jang, T.S.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.482-488
    • /
    • 2006
  • Application of precision farming technology to rice cultivation could be an effective measure for rice quality improvement and environment-friendly agriculture. This study was conducted to develope a variable rate pneumatic granule applicator. Previous study reported that application uniformity of the prototype machine (C.V. = 23.3%) was not satisfactory. To improve the uniformity, increase of blow-head number from 12 to 16 was suggested. Analysis of the pneumatic conveying system showed that increase of number of blow-head was possible. Three-way variance analysis of the modified applicator showed that inserting length should be changed according to granule metering rate. The range of metering rate from 27.3 to 417.9 g/s were divided into 4 levels and 4 sets of inserting lengths were determined to ensure CV values less than 15%. The revised applicator showed satisfactory C.V. values of 9.4 to 14.6% in the metering rate. Granule conveying pattern was observed using a high speed camera and judged as the homogeneous flow pattern.