• Title/Summary/Keyword: Meter-out control

Search Result 81, Processing Time 0.032 seconds

A Study on the Field Application of Automatic Grouting System (자동화 그라우팅 기법의 현장적용성에 관한 연구)

  • Do, Jongnam;Park, Junghwan;Choi, Dongchan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2012
  • In Korea, grouting has been mostly designed and constructed by experiences without expert knowledge and theoretical study. So there are a lot of problems related to the quality and safty of grouting. Therefor, in this paper the quality management skills and method were discussed through out by using the auto-grouting method and field test of grouting for the construction. Through the limit water injection test of the soil, it make the optimum injection pressure and injection speed of grouting, and through the lugeon test of the rock, it make assess the permeability of before and after grouting. In order to prevent the hydraulic fracture of soil and break away from the grouts if it apply four kinds of mode of grouting stop criteria, injection effects can be improved. From the above characteristcs designers evalute the fitness values of injection pressure(p), injection speed(q) and grouting penetration time(t). So far, to record and manage pressure(p) and speed(q) of grouting autographic devices such as intergation flow-meter usually record data in a roll of paper. Intergration flow-meter can record grouting flow quantity exactly, but the recorded pressures differ from the any basis such as intitial, intermediate and final point. Therefore, it has been argued that is a need of reliable method to describe the connection between the pressure recorded by an intergration flow-meter and the special properties of the grouting target ground. auto-grouting method can describe the reliable connection between the grouting pressure and the special properties of the grouting target ground. So, in this paper by using auto-grouting method, it is expected that to secure basis of quality control techniques construction.

The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray (이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가)

  • Lee, Hae-Jung;Kim, Ho-Sung;Kim, Eun-Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

Measurements of Streambed Hydraulic Conductivity Using Drive-point Piezometers and Seepage Meters in the Upper Reaches of Anseong Stream (관입형 피조미터와 시피지미터를 이용한 안성천 상류구간 하상 수리전도도 측정)

  • Lee, Jeongwoo;Chun, Seon Geum;Yi, Myeong Jae;Kim, Nam Won;Chung, Il-Moon;Lee, Min Ho
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.413-420
    • /
    • 2015
  • Streambed hydraulic conductivity along the upper reaches of the Gongdo stage of Anseong Stream was estimated through measurements of stream-aquifer exchange rates (using a seepage meter) and vertical hydraulic gradients (using a manually driven piezometer). From the measured data, it was found out that the stream-aquifer exchange rates varied from -1.55 × 10-6 to 1.77 × 10-5 m/s, the corresponding vertical hydraulic gradient varied from -0.122 to 0.030, and the values of the streambed vertical hydraulic conductivity were estimated from 1.77 × 10-5 to 1.97 × 10-3 m/s, with variations representing local differences. The results are within the general range of streambed hydraulic conductivity values suggested by Calver (2001) and are slightly higher than values previously measured at other stream sites in Korea. The combined use of a drive-point piezometer and seepage meter (both constructed of high-strength stainless steel) is expected to be of practical use in the estimation of streambed hydraulic conductance, given the durability and portability of the instruments.

Experimental Analysis of Flow Characteristics around Wind-Turbine Blades (풍력터빈 블레이드 주위 흐름의 유동특성에 대한 실험적 분석)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.64-71
    • /
    • 2010
  • The flow and noise characteristics of wake behind wind-turbine blades have been investigated experimentally using a two-frame particle image velocimetry (PIV) technique. Experiments were carried out in a POSTECH subsonic large wind-tunnel ($1.8^W{\times}1.5^H{\times}4.3^L\;m^3$) with KBP-750D (3-blade type) wind-turbine model at a freestream velocity of $U_o\;=\;15\;m/s$ and a tip speed ratio $\lambda\;=\;6.14$ (2933 rpm). The wind-turbine blades are connected to an AC servo motor, brake, encoder and torque meter to control the rotational speed and to extract a synchronization signal for PIV measurements. The wake flow was measured at four azimuth angles ($\phi\;=\;0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$) of the wind-turbine blade. The dominant flow structure of the wake is large-scale tip vortices. The turbulent statistics such as turbulent intensity are weakened as the flow goes downstream due to turbulent dissipation. The dominant peak frequency of the noise signal is identical to the rotation frequency of blades. The noise seems to be mainly induced by the tip vortices.

The Effect of Electron Beam Irradiation on Discoloration and Thermal Property of HDPE Filled with Antioxidants and UV Stabilizers (전자선 조사에 따른 산화방지제 및 자외선안정제 첨가 HDPE의 변색 영향과 열적 특성 분석)

  • Jeun, Joon Pyo;Jung, Seung Tae;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • In this study, we fabricated high density polyethylene (HDPE) composites filled with antioxidants and UV stabilizers. The electron beam irradiation on the fabricated composites was carried out over a range of absorbed doses from 50 to 200 kGy to confirm the changes of discoloration. The changes of discoloration were characterized using a color difference meter and FT-IR for confirming the changes of the color difference and structural change. It was observed that the color difference of IRGANOX 1010-, IRGAFOS 168-, and TINUVIN 328- added HDPE was higher than that of the control HDPE by electron beam irradiation. The melting temperature of UV stabilizer-added HDPE was not significantly changed by electron beam irradiation. However, the melting temperature of phenol-containing antioxidant-added HDPE was increased with increasing the absorbed dose. And the melting temperature of phosphorus-containing antioxidant-added composite was decreased with increasing the absorbed dose.

Effect of the Combined Use of FES and Over ground Walking with Partial Body-Weight Support on Walking and Balance Competency in Patients with Chronic Strokes (FES와 부분적인 체중지지를 결합한 지상보행훈련이 만성 뇌졸중 환자의 보행과 균형에 미치는 영향)

  • Wang, Gye-Seok;Yoon, Se-Won;Cho, Woon-Su;Kim, Yong-Nam
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.15-22
    • /
    • 2012
  • Purpose : We investigated the effects of the combined use of FES and over ground walking with partial body-weight support (PBWS) on walking function and balance control in people with chronic strokes. Methods : Twenty-seven people who were ambulatory after chronic strokes were evaluated. The exercise's intervention consisted of the combined use of FES and over ground walking with PBWS and general exercise groups. The FES + PBWS group and general exercise group consisted on a-20-minute session per day, 3 times a week during a 4 week period. The evaluation was carried out before, after, and two weeks after the exercise intervention. Outcome measures were a 6 Minute Walk Test, 6-Meter walk Test, Timed Up and Go Test, and a Balance Test, measured before and after the exercise interventions at a-2 week follow up. Results : The endurance was significantly increased in both the FES+PBWS group and general exercise group (p<0.05). Significant increase on the gait velocity was observed in both the FES+PBWS group and general exercise group (p<0.05). The TUG was significantly different in both the FES + PBWS group and general exercise group (p<0.05). However there were no differences in both the between-group & interaction. The stability index was significantly different in both the FES + PBWS group and general exercise group (p<0.05). Conclusion : In conclusion, the combined use of FES and over ground walking with PBWS led to an improvement in walking function and balance control. Thus, it is possible to combine the use of FES and over ground walking with PBWS for physical therapy intervention to improve walking function and balance control. It is suggested to apply this intervention in the clinical field.

Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University (선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.

The outbreaks and counterplan of highly pathogenic avian influenza in Korea and overseas (국내.외 조류인플루엔자(HPAI) 발생현황과 대응방안)

  • Jang, Hyung-Kwan
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.220-227
    • /
    • 2009
  • For last about 10 years, the Republic of Korea experienced 3 times of outbreaks of highly pathogenic avian influenza (HPAI) from 10 December 2003 to 30 April 2004 (a total number of 19 outbreaks), 22 November 2006 to 6 March 2007 (a total number of 7 outbreaks), and 1 April 2008 to 12 May 2008 (a total number of 33 outbreaks). Among the totally 59 outbreaks, the infected premises included 35 chicken farms, 17 duck farms, 1 quail farm, and 6 farms rearing mixed species. Control measures were applied according to the HPAI standard operation procedure including depopulation of all infected and suspected flocks, movement restrictions, and disinfection of the infected farms within a 500-meter radius. Including movement restrictions, stringent control measures were additionally applied to two designated zones: the protection zone was an area within a 3-kilometer radius of the outbreak farm, and the surveillance zone was an area between a 3- to 10-kilometer radius of the outbreak farm. Farms with dangerous contacts and/or all of poultry within the protection zone was subjected to preemptive culling. Epidemiological investigations were also carried out including trace-back and trace-forward investigations to identify possible sources of spread and dangerous contact farms. Investigation teams conducted on-site examination of farm premises and facilities, interview with farm owner and staff, and review of records. Genetic and pathogenic characteristics of the virus isolates, and the results of the various surveillance activities were also analyzed. HPAI surveillance conducted in Korea includes passive surveillance of investigating notified cases, and active surveillance of testing high risk groups and areas. HPAI is a notifiable disease in Korea and all suspect cases must be reported to the veterinary authorities. Cases reported for other poultry diseases that require differential diagnosis are also tested for HPAI. Active surveillance includes annual testing of breeder duck farms, broiler duck farms and wild bird surveillance, which is concentrated during the autumn and winter. Surveillance activities conducted prior to the outbreaks have shown no evidence of HPAI infection in Korea.

  • PDF

Effect of Treadmill Training and Proprioceptive Neuromuscular Facilitation Lower Leg Taping on Balance and Gait Ability in Stroke Patients (고유수용성신경근촉진법 아래다리 테이핑적용과 트레드밀 훈련이 뇌졸중 환자의 보행능력과 균형능력에 미치는 영향)

  • Jeong, Wang-Mo;Kim, Beom-Ryong;Kang, Mi-Gyeong
    • PNF and Movement
    • /
    • v.14 no.2
    • /
    • pp.83-91
    • /
    • 2016
  • Purpose: The purpose of this study was both to examine the effects of proprioceptive neuromuscular facilitation (PNF) lower leg taping and treadmill training on the gait and balance abilities of patients with hemiplegia resulting from a stroke and to provide a taping method based on the PNF concept. Methods: Twenty patients with hemiplegia resulting from a stroke were randomly and equally assigned to a control group (n=10), which received treadmill training, and to an experimental group (n=10), which received PNF lower leg taping and treadmill training. The intervention was conducted five times per week for six weeks. In order to measure changes in the gait ability of the subjects, a 10-meter walking test (10MWT) and a 6-minute walking test (6MWT) were conducted, and in order to measure changes in the subjects' balance ability, a timed up and go test (TUG) was performed. In order to compare differences within each group before and after the intervention, a paired-t test was carried out, and in order to compare differences between the two groups, the analysis of covariance was utilized. All statistical significance levels were set at ${\alpha}=0.05$. Results: There were significant differences before and after the intervention within both groups in changes of 10MWT, 6MWT, and TUG (p<0.01). Regarding differences between the two groups, the experimental group underwent more effective changes than the control group in 6MWT and TUG (p<0.05). Conclusion: This study applied PNF lower leg taping and treadmill training to patients with hemiplegia resulting from a stroke, and this resulted in improvement in the subjects' gait and balance abilities. Taping and treadmill training based on the PNF concept is considered to be usefully applied as one of the programs to improve hemiplegic patients' gait and balance abilities.

A Study on the Environmental Condition and Safety in Dental Radiography Room (치과방사선 촬영실의 환경 및 안전성에 관한 연구)

  • Park, Il-Soon;Lee, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.49-64
    • /
    • 2004
  • This study is designed to conduct a questionnaire research into the safety control and the actual condition of radiography by working with dentistry belonging to university hospitals, dental hospitals and dental clinics for three months ranging from August, 2003 to October, 2003. The researcher came to the following conclusions. 1. The research on the current condition of possessed radiational equipment shows that 61.2 percent of the subjects had one intraoral radiation medicine and that 70.1 percent of the subjects had more than one extraoral radiation medicine and that 37.3 percent of the subjects had more than one digital radiation medicine. 2. Most of intraoral radiography (82.1%) was conducted by dental hygienists, and 7.5 percent of intraoral radiography was conducted by nurse aids. On the other hand, most of extraoral radiography (76.6%) was conducted by dental hygienists and digital radiography was conducted by dental hygienists(60.6%), dentists(32.0%) and radiographer(80.0%). 3. The less-than 1-meter-long distance between cone and the radiographer accounted for 44.8 percent. And the more-than 1.6-meter-long distance accounted for no more than 13.4 percent. The exposure time per standard film which was adjusted to each part accounted for 71.6 percent. Fixing the film on the part of healthy patients accounted for 76.1 percent. Fixing the film of elderly patients and children patients by the radiographer accounted for 43.3 percent. 4. The average daily photographing frequency of standard films stood at six to ten pieces(31.3%), and the average weekly photographing frequency of bitewing films stood at less than one piece(47.8%), and the dentistries where bitewing films were not employed accounted for 25.4%. The subjects whose average weekly photographing freqeuncy of occlusal films stood at less than a piece accounted for 59.7 percent. The dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 41.8 percent. In case of panorama & cephalo, one to five pieces on a weekly average accounted for 36.2 percent. The dentistries whose average daily photographing frequency of digital radiation medicine stood at less than 1 piece accounted for 40.0 percent. 5. The research on the use of protective clothes shows that pregnant ·women only accounted for 31.3 percent. In regard to the use of protective clothes in case of the radiographers fixing films, the cases where no protective clothes were employed accounted for 88.1 percent. The reason was said to he attributable to the trouble related to wearing the clothes(54.2%). 6. The survey on the measurement of exposure dose shows that the cases where no measurement was made accounted for 76.1 percent. As far as the measurement methods of exposure dose was concerned, the employment of film badge accounted for 68.8 percent. The subjects turned out to conduct measurement of exposure dose every third month, which accounted for 43.8 percent. The barriers to the measurement of measurement of exposure dose were attributable to the recognition that a little amount of exposure dose need not be measured(29.9%). 7. The survey on the distinction of radiation rooms and clinic rooms reveals that the cases where radiation rooms exclusively existed accounted for 67.2 percent. 43.3 percent of the subjects turned out to have only one protective garment, and 49.3 percent of the subjects proved to conduct a periodical checkup of radiational equipment. The survey on the examination certificates of radiational generators and protective facilities indicates that 80.6 percent of the subjects had the certificates. The research also shows that the subjects with the marks indicating the radiational areas accounted for 70.1 percent. And trustees turned out to handle developing solutions and fixing solutions.

  • PDF