• 제목/요약/키워드: Meter-in circuit

검색결과 81건 처리시간 0.021초

칩마운트 (SMD) 장비의 동하중(動荷重) 발생특성에 관한 실험적 연구 (An Experimental Study on the Dynamic Load Characteristics of Surface Mount Device(SMD))

  • 백재호;이홍기;김강부
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1913-1917
    • /
    • 2000
  • SMD Equipment convey an electronic parts at high speed, then assemble parts into a circuit board, and it develop a long time-duration dynamic force to be caused by moving mass. Vibration problem to be caused by SMD Equipment have an effect on micro-meter level's precision production process, directly, and dynamic stability of building. In the cause of quantitatively access about its vibration problem, input information(or data) of structure dynamic analysis need accuracy information of dynamic load. Determination of Dynamic load is various kinds of method using experimental and theory. In this paper, we got dynamic load using direct measurement method. We expect that an study on the dynamic load characteristic of SMD can be used to Equipment development of low level vibration and basis information of structure dynamic analysis.

  • PDF

열선을 이용한 혼합기체의 농도와 유량의 측정 (Measurement of Gas Concentration and flow Rate Using Hot Wire)

  • 김영한;최종정
    • 제어로봇시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

$PbTiO_3$ 박막의 적외선 스펙트럼특성과 초전감지소자의 모델링에 관한 연구 (A Study on IR Spectrum Characteristics of $PbTiO_3$ Thin Film and Pyroelectric Detector Modeling.)

  • 김성민;이문기;김봉열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.439-443
    • /
    • 1987
  • $PbTiO_3$ thin film is prepared by rf sputtering method to implement the pyroelectric infrared detector at room temperature. Annealing of $PbTiO_3$ thin film is done from $400^{\circ}C$ to $550^{\circ}C$ each for 2 hours in furnace. The spectral response to recrystallization process of $PbTiO_3$ thin film is measured by IR photospectro meter. Pyroelectric detector Modeling is studied for implementing device using electrical equivalent circuit model. It is found that $PbTiO_3$ thin film has two IR absorption band within $1000-400\;cm^{-1}$ (10um-25um) and it's spectral response is improved as annealing temperature increase. As a result of pyroelectric detector modeling, we find the possibility of implementing optimum device structure.

  • PDF

성능이 향상된 면적선량계(DAP) 개발 (Development of Enhanced DAP(Dose Area Product))

  • 이영지;이상헌;이승호
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.739-742
    • /
    • 2019
  • 본 논문에서는 성능이 향상된 면적선량계(DAP)를 제안한다. 본 논문에서 제안한 성능이 향상된 면적선량계는 기존에 개발되었던 면적선량계를 최적화하였다. 성능이 향상된 면적선량계는 전하 적분기 및 ADC 회로의 최적화 설계, RS-485 통신용 Line transceiver의 최적화 설계, Display 회로의 최적화 설계, 연동 및 에이징을 위한 PC 기반 제어 프로그램 최적화 등을 수행하였다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 Radiation dose dependence와 Radiation quality dependence는 4.2%의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. Energy range/Tube voltage는 30~150kV 구간에서 반응이 확인되었다. 센서필드간 감도차이와 센서필드간 면적선량 감도차이는 4.3%의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. 면적선량계의 재현성을 측정하기 위하여 10회 반복하여 측정한 결과 0%로 확인되어서 IEC60580 권고 사항인 2% 이하에서 정상동작 됨이 확인되었다. Digital resolution은 시간당 기준선량에 대해 오차 범위 내에서 $0.01{\mu}Gy{\cdot}m^2$의 최소단위로 측정되는 것을 확인되었다.

다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현 (Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe)

  • 강법주;김양수
    • 한국정보통신학회논문지
    • /
    • 제20권1호
    • /
    • pp.175-184
    • /
    • 2016
  • 본 논문에서는 기존의 LCR 미터에 의한 측정방식이 아니라 C/V(capacitance to voltage) 변환 방식을 이용하여 커패시턴스를 측정하는 방법을 제안하였다. 그리고 다중채널용 초음파 프로브 진단장치를 구현하기 위해 192채널들을 6개의 MUX(multiplexer) 채널로 변환하는 아날로그 MUX 회로를 설계하였다. 각각의 MUX 채널 회로별 전압을 다시 커패시턴스로 변환하는 회로특성이 다르기 때문에 각각의 MUX 채널별 디지털전압을 커패시턴스로 변환하는 변환함수를 최소 자승법을 이용하여 유도하였다. 개발된 시제품의 성능시험결과로 1회 측정시간이 4초 이내로 측정되었고, 192개 채널들의 반복적인 측정에서 최대값, 최소값, 평균값에 대한 측정 오차값이 5% 이내의 시험결과가 제시되었다.

산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현 (Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site)

  • 장문석;이응혁
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구 (A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.552-558
    • /
    • 2014
  • 본 논문에서는 원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계방법을 제안한다. 제안된 ZigBee 원칩형 통신모듈 설계는 ZigBee 시스템 구성을 위해 일반적으로 사용되는 2개의 칩 제어 프로세서와 ZigBee RF 디바이스로 구성되는 방식을 한 개의 칩 모듈로 설계한다. 원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈은 무선통신 통합제어부, 센서 및 고전압 발생부, 충전 및 전원회로부, 유선통신부, RF 회로부 및 안테나부 등으로 구성된다. 무선통신 통합제어부는 ZigBee를 위한 무선통신 제어 기능 및 방사선 측정 및 제어를 위한 기능을 수행한다. 센서 및 고전압 발생부는 2차에 걸쳐 500V의 고전압을 생성하여 GM Tube를 통해 감지된 방사선에 대한 펄스를 증폭 필터링 하는 기능을 수행한다. 충전 및 전원회로부는 리튬이온 배터리의 충전 및 원칩 프로세서에 전원을 공급하는 기능을 수행한다. 유선통신부는 PC와의 인터페이스 및 디버깅을 위한 USB 인터페이스 및 원거리 유선 통신이 가능하도록 RS-485/422 인터페이스 기능을 수행한다. RF 회로부 및 안테나부는 칩안테나를 적용할 수 있도록 RLC 수동소자를 적용하여 BALUN 및 안테나 임피던스 매칭 회로를 구성하여 무선통신이 가능하도록 한다. 제안된 원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈을 설계 실험한 결과, 10m, 100m 구간에서 모두 데이터가 정상적으로 전송되어서 원격 방사선량 측정이 되었음을 확인할 수가 있었다. 또한 낮은 소비전류와 적은 비용으로 원격 방사선량 측정환경을 구축할 수 있었다. 따라서 방사선 측정장치의 선형성 확보 및 장치의 소형화를 통해 안정적인 방사선 측정 및 실시간 모니터링 환경을 구축할 수가 있었다.

RF Front End의 결함 검출을 위한 새로운 온 칩 RF BIST 구조 및 회로 설계 (New On-Chip RF BIST(Built-In Self Test) Scheme and Circuit Design for Defect Detection of RF Front End)

  • 류지열;노석호
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.449-455
    • /
    • 2004
  • 본 논문에서는 입력 정합(input matching) BIST(Built-In Self-Test, 자체내부검사) 회로를 이용한 RF front end(고주파 전단부)의 새로운 결함 검사방법을 제안한다. 자체내부검사 회로를 가진 고주파 전단부는 1.8GHz LNA(Low Noise Amplifier, 저 잡음 증폭기)와 이중 대칭 구조의 Gilbert 셀 믹서로 구성되어 있으며, TSMC 40.25{\mu}m$ CMOS 기술을 이용하여 설계되었다. catastrophic 결함(거폭 결함) 및 parametric 변동 (미세 결함)을 가진 고주파 전단부와 결함을 갖지 않은 고주파 전단부를 판별하기 위해 고주파 전단부의 입력 전압특성을 조사하였다. 본 검사방법에서는 DUT(Device Under Test, 검사대상이 되는 소자)와 자체내부검사회로가 동일한 칩 상에 설계되어 있기 때문에 측정할 때 단지 디지털 전압계와 고주파 전압 발생기만 필요하며, 측정이 간단하고 비용이 저렴하다는 장점이 있다.

하천유량측정의 효율성 향상을 위한 범용 전자파표면유속계 개발 (Development of Microwave Water Surface Current Meter for General Use to Increase Efficiency of Measurements of River Discharges)

  • 김영성;노준우;최광순
    • 생태와환경
    • /
    • 제47권3호
    • /
    • pp.225-231
    • /
    • 2014
  • 본 연구는 홍수기 유량측정의 어려움을 극복하고자 물과 비접촉식으로 유속을 측정하여 유량을 산정하는 전자파표면유속계(microwave water surface current meter, MWSCM)의 성능개선 제품인 범용 MWSCM에 대하여 소개하고자 하였다. 기존에 사용 중인 MWSCM은 홍수용으로써 연중 활용도가 낮아 이것의 이용성을 높이고자 성능을 개선하였다. 유속측정 범위를 확장하여 평 갈수기에도 하천 유량측정이 가능하게 하였다. 즉 기존 홍수용 MWSCM의 유속측정 범위가 $0.5{\sim}10.0ms^{-1}$이었던 반면, 금번에 개발된 범용 MWSCM은 $0.03{\sim}20.0ms^{-1}$로 홍수기 및 평수기 측정이 가능하도록 성능을 개선하였다. 이를 위해서 사용주파수의 변경($10GHz{\rightarrow}24GHz$), 안테나 및 송수신부 회로가 새롭게 설계 제작되었다. 이와 더불어 기존 홍수용 MWSCM 사용자들의 개선요구사항-기기 경량화, 유속 안정화, 자체점검기능, 저전력, 방수 및 방습-을 파악하여 반영함으로써 현장에서 유량을 측정하기에 용이한 기기로 개발하였다.

공압 수직실린더의 쿠션특성에 관한 실험적 연구 (An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted.)

  • 김동수;김형의;이상천
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF