• 제목/요약/키워드: Metals' ratio

검색결과 658건 처리시간 0.031초

Aspergillus niger의 생물 흡착제를 이용한 납이온의 흡착 (Adsorption of lead ion by using biomass of Aspergillus niger)

  • 김병하;김장억;문성훈;김희식;오희목;윤병대;권기석
    • 한국토양환경학회지
    • /
    • 제1권2호
    • /
    • pp.43-50
    • /
    • 1996
  • The adsorption charateristics of lead(II) ions on Aspergillus niger and Rhizopus arrhizus were investigated. Adsorption amount of A. niger and R. arrhizus was about 95 mg/g and 25 mg/g, respectively. These biomass was approached to adsorption equilibrium within reaction time of 1hr because of their high reactivity. The uptake of lead ion by A. niger was less sensitivity than it by R. arrhizus on the inhibition effect of alkali metals and the decreasing ratio of uptake of lead ion of A. niger and R. arrhizus by inhibition effect of alkali metals was 37% and 50%, respectively. In pre-treatment on these biomass, NaOH treatment was contributed high adsorption capacity to these biomass. Then, adsorption amount of A. niger and R. allhizus was increased about 25 mg/g and 10 mg/g, respectively. In isotherm for the adsorption of lead ion based on Freundlich equation, 1/n value of A. niger and R. ar고izus was calculated the range of 0.28-0.56 and 0.44-0.67, respectively.

  • PDF

레이저 이종용접에서의 입열량 변화에 대한 용접특성 (Welding Characteristics on Heat input Changing of Laser Dissimilar Metals Welding)

  • 모양우;신병헌;신호준;유영태
    • 한국공작기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.51-58
    • /
    • 2006
  • Laser welding of dissimilar metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for SM45C and STS304 with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the dissimilar welding, the welding quality of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding qualify is 1600W of the laser power, 0.85m/min of welding speed and $4{\ell}/min$ of pressure for shielding gas.

CW Nd:YAG 레이저를 이용한 냉연강판의 용접특성 (Welding Characteristics of Cold Rolled Carbon Steel utilize CW Nd:YAG Laser)

  • 신병헌;유영태;신호준;안동규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.17-18
    • /
    • 2006
  • Laser welding of metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for metals with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the butt welding, the welding quality of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding quality is 1400W of the laser power, 0.8m/min, 0.9m/min of welding speed and $4{\ell}$ in of pressure for shielding gas.

  • PDF

지방산과 폴리에틸렌글리콜의 혼합에 따른 수용성 절삭유제의 절삭특성 (Drilling Properties of Water-Based Metal Working Fluid Containing Fatty Acid and Polyethylene Glycol)

  • 김영운;정근우;윤유정;김세훈;강석춘
    • 한국정밀공학회지
    • /
    • 제18권2호
    • /
    • pp.161-170
    • /
    • 2001
  • Synthetic water-based metal-cutting fluids are increasingly popular in the metal-working industry because of its environmental friendliness. The propose of this study is to investigate the synergistic effect of combining polyethylene glycol and common fatty acid in formulating a metal-cutting fluid. The tested metals were aluminum, copper and steel, and the test was performed with a modified drilling machine. From the study, it was found that there existed some synergistic effects on the drilling efficiency of the metals to decrease of cutting time, cutting energy, torque as well as the smoothness of surface depended on the formulation ratio of the two fluids.

  • PDF

중금속 오염 농경지 토양의 복원을 위한 현장실증시험 결과 (A Result of Field Demonstration Experiment on the Remediation of Farm Land Soil contaminated by Heavy Metals)

  • 유찬;윤성욱;박진철;이정훈;최승진;윤성문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.265-277
    • /
    • 2009
  • A long-term field demonstration experiment of selected stabilization method to reduce the heavy metal mobility in farmland soil contaminated by heavy metals around abandoned mine site was conducted. Field demonstration experiments were established on the contaminated farmland with the wooden plate(thickness=1cm) which dimension were width=200cm, Length=200cm, height=80cm and filled with treated soil, which was mixed with lime stone and steel refining slag except on control plot. Soil samples were collected and analyzed during the experiment period(2008. 2~2008. 8) after the installation of the plots. Field demonstration experiments results showed that the application ratio of lime stone 5% was effective for immobilizing heavy metal components in contaminated farmland soil.

  • PDF

2-Oximino-1-indanone을 이용한 Pt(IV) ion의 정량에 관한 연구 (Spectrophotometric Determination of Platinum (IV) with 2-Oximino-1-indanone)

  • 김정균;유미경;원미숙;심윤보;고영심
    • 약학회지
    • /
    • 제28권2호
    • /
    • pp.61-67
    • /
    • 1984
  • A method is described for the spectrophotometric determination of platinum (IV) with 2-oximino-1-indanone based on solvent extraction of Pt:2-oximino-1-indanone complex. The 2-oximino-1-indanone reacted with Pt(IV) to form a dark-orange complex which shows a characterisic maximum absorption at 342nm. The optimum PH for the platinum extraction lies between 5.4~8.0. Beer's law obeys up to 0.98-16.3ppm of platinum (IV) and the molar absorption coefficient is $1.06{\times}10^{-4}L.mol^{-1}.cm^{-1}$. The relative standard deviation of the method was $\times2.1%$. The composition of the complex is estimated to be Pt : In= 1 : 1, by the mole ratio method and ion exchange resin experiment. The optimum condition for the determination of platinum has been studied in detail. The 2-oximin-1-indanone is found to be a selectivereagent for the determination of platinum, since the synthesixed 2-oximino-1-indanone did not react with other metals such as cobalt, cadmium, copper, manganese nickel, iron, lead and zinc, to form the complex. In this studies, we have also clarified Sindhwani and Singh's spectrophotometric determination data of various metals with acenaphthenequinone monooxime (Talanta 20,248, 1973), whose results were not correct.

  • PDF

정형 보철용 금속이 자기공명영상에 미치는 영향 III (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging III)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.42-47
    • /
    • 2012
  • Followed by a paper on the Pig and Bone orthopedic prosthetic, this experiment using Phantom and Bone MRI imaging I, II of orthopedic prosthetic metal effect combines magnetic resonance imaging on metal signal-to-noise ratio(Signal to noise : SNR) and CNR(Contrast to noise: CNR), fat signal suppression(Fat-suppression) images was compared. Specimen trees to measure the reliability of the experimental reproducibility tests and statistical analysis using the SPSS statistical package was applied program SPSS(IBM SPSS Statistice 19) by * P = 0.000 < significance level $({\alpha})$ = 0.01 as a significant there was a correlation(** P < 0.01). SNR and CNR results did not directly proportional to the Titanium, Stainless, Clip CNR and fat signal suppression of the order of images of blood specimens was found to be close to the image. The impact of orthopedic prosthetic metals on magnetic resonance imaging in the diagnostic value of Titanium is relatively high and are meant more.

불꽃원자 흡수 분광법의 Micro Sampling Technique 에 의한 미량 중금속의 분석에 관한 연구 (A Study on the Determination of Some Heavy Metals using Micro Sampling Technique in Flame Atomic Absorption Spectrophotometry)

  • 이원
    • 대한화학회지
    • /
    • 제29권3호
    • /
    • pp.220-225
    • /
    • 1985
  • 불꽃 원자 흡수 분광법의 Micro Sampling Technique을 이용하여 염의 농도가 높고, 양이 제한된 시료중에 미량으로 함유된 Cu, Zn 및 Fe의 분석을 시도하였다. 최적기간 및 분석조건을 조사한 결과 측정시간 0.3초, 시료부피 100${\mu}l$, 시료의 흡입속도 7.5ml/min, 연료와 산화기체의 혼합비 2.0 및 버어너 높이는 Cu일때 6.0mm, Zn 및 Fe는 8.0mm이었다. 이 방법을 일반적인 불꽃 방법과 비교하여 보면 시료의 전처리 과정이 필요없이 간단하고, 비교적 정밀성과 정확성이 있으며, 특히 100${\mu}l$정도로 양이 제한된 시료와 약 20% 정도로 염의 농도가 높은 시료의 경우도 버어너 틈새가 막히지 않고 안정한 불꽃에서 분석이 가능하였다.

  • PDF

레이저 이종용접에서의 입열량 변화에 대한 용접특성 비교 (Comparison of Welding Characteristics on Heat input Changing of Laser Dissimilar Metals Welding)

  • 신호준;유영태;신병헌;안동규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.997-1003
    • /
    • 2005
  • Laser welding of dissimilar metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for SM45C and STS304 with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the dissimilar welding, the welding qualify of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding quality is 1600W of the laser power, 0.85m/min of welding speed and 4m/min of pressure for shielding gas.

  • PDF

Effect of Pre-treatments on the Content of Heavy Metals in Packaging Paper

  • Jo, Byoung-Muk;Jeong, Myung-Joon
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.465-469
    • /
    • 2006
  • Pre-treatment methods to determine various heavy metal contents in packaging papers were investigated by ICP-ES (Inductively Coupled Plasma Emission Spectrometry) analysis. Pre-treatment methods utilized in this study include dry ashing and decomposition methods ($HNO_{3-}HClO_{4-}HF,\;HNO_{3},\;and\;H_{2}SO_{4-}HNO_{3}$). They were compared with the conventional extraction (water) and migration (3% acetic acid) methods. The five representative heavy metals (Cd, As, Pb, Cr and Hg) were analyzed. For Cd, Hg, and As, the results were below detection limit of the instrument. In case of Cr and Pb, the migration test is considered to be a better method compared to the extraction test, but all pretreated methods showed much higher detection efficiency than the extraction or migration test. However, the detection ratio between the migration test and decomposition methods was different. Among all decomposition methods, the nitric acid - perchloric acid - hydrofluoric acid treatment brought a slightly higher detection value than others, but there was no significant difference among them except sulfuric acid - nitric acid method. Concerning Pb, the sulfuric acid - nitric acid method showed a low detection efficiency compared to other decomposition methods. The sulfuric acid - nitric acid method is, thus, not considered to be a suitable analysis method for Pb in packaging papers.

  • PDF