• 제목/요약/키워드: Metal-cored wire

검색결과 37건 처리시간 0.02초

FCAW에서 용접금속 확산성수소량에 미치는 용접변수 영향의 정량적 해석 (Quantitative Analysis on the Effects of Welding Parameters on Diffusible Hydrogen Contents in Weld Metal Produced by FCAW Process)

  • 한동우;방국수;정홍철;이종봉
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.54-59
    • /
    • 2010
  • The effects of welding parameters such as contact tip-to-work distance (CTWD), voltage, and current on the weld metal diffusible hydrogen contents (HD) were investigated and rationalized by the calculation of heating time and amount of heat generated in the extension length of flux cored wire. As CTWD increased from 15 to 25mm, HD decreased from 8.46 to 5.45mL/100g deposited metal. Calculations showed that, with an increase of CTWD, the amount of heat generated increased from 46 to 92J in addition to an increase of heating time. Increase of current from 250 to 320A, however, gave little variation of HD. It showed that no significant change in the amount of heat generated was found, and heating time was decreased with an increase of current. It also showed that CTWD is more influential than voltage in relatively lower heat input ranges, while voltage is more in higher input ranges

건축용 강 구조물의 용접기술 (Welding Technologies in the Steel Structure for Building)

  • 윤중근;박동환
    • Journal of Welding and Joining
    • /
    • 제12권3호
    • /
    • pp.18-25
    • /
    • 1994
  • 최근 건축용 강구조물이 초대형화 및 초고층화됨에 따라 용접물량의 급증하고 있으나 3D 직종에 대한 회피현상으로 용접기능자의 감소 및 인건비의 급증 등으로 인하여 건축용 강 구조물 제작시 경쟁력이 갈수록 저하되고 있다. 이에 대한 자구책으로 강 구조물 제작업체에서는 생산 성을 한층 배가 시킬 수 잇는 용접시공 기술을 자체 개발하거나 외부로부터 도입하고 있다. 본 보에서는 당사를 비롯하여 여러 업체에서 최근 개발된 용접기술 특히 대전류 SAW 기법, SESNET 기법 등의 초대입열 용접기술, Metal cored wire나 TIME 기법에 의한 고능률 GMAW 기법 및 Robot 용접 등에 대하여 간략히 기술하였다. 이 용접기술들의 적용에는 대개 고가의 시설투자가 수반되나, 이는 생산성 증가에 따른 원가절감으로 충분히 상쇄될 수 있다. 그러나 상기된 용접기술들의 적용에 대한 성패는 용접장비의 특성, 용접조건의 확립, 모재의 특성 혹은 주변 자동화 기술 및 상호 종속적인 관계에 크게 의존된다. 따라서 가 강 구조물 제작업체에서는 세심한 주위환경 분석을 토대로 각 업체에 가장 합당한 용접기술을 선정 및 적용하여야 하겠다.

  • PDF

선박조립과정의 FCAW 적용시 적정 보호가스 유량에 대한 연구 (A Study of Optimum Shielding Gas Flow Rate in FCAW for Shipbuilding)

  • 이훈동;심천식;송하철;염재선
    • 대한조선학회논문집
    • /
    • 제48권1호
    • /
    • pp.76-83
    • /
    • 2011
  • FCAW(Flux Cored Arc Welding) is a widely used welding method in shipbuilding. It also conducts WPS(Welding Procedure Specification) requested by the classification variations of the factors which affect the quality on the welded area such as thickness of base metal, type of welding wire and shielding gas etc. which has to be satisfied. CO2 is commonly used as a shielding gas for FCAW due to the economic point of view. The amount of shielding gas is stated when classification certify WPS. However, the shielding gas is unnecessarily used at the shipyard leaning only on the welder's experience as there are classification standards for using the shielding gas. It causes production cost to rise. Also recently, CO2 is a main contributor for global warming, and large amounts of CO2 are discharged into the atmosphere during shipbuilding processes without any filtration. Therefore it was confirmed by the security of the welded area as a result of conducting the destructive and non-destructive tests with setting up the factors and the standards by using the Taguchi method. Then the FCAW shielding gas's amounts were calculated precisely when assembling a ship. It will be applied to cost reduction and prevention of environmental pollution at the shipyard.

합금강(ASTM A387 Gr. 91) - 탄소강(ASTM A516 Gr.70) 이종금속의 FCA 다층 용접부 특성 평가 : Part. 2 (A Study of Characteristics on the Dissimilar Metals (Alloy steel : A387 Gr. 91 - Carbon Steel : A516 Gr. 70) Welds Made with FCA Multiple Layer Welding: Part 2)

  • 신태우;현준혁;고진현
    • Journal of Welding and Joining
    • /
    • 제35권3호
    • /
    • pp.68-74
    • /
    • 2017
  • Characteristics of dissimilar metal welds between alloy steel ASTM A387 Gr. 91 and carbon steel ASTM A516 Gr.70 made with Flux cored arc welding(FCAW) have been evaluated in terms of microstructure, mechanical strength, chemical analysis by EDS as well as corrosion test. Three heat inputs of 15.0, 22.5, 30.0kJ/cm were employed to make joints of dissimilar metals with E71T-1C wire. Post-weld heat treatment was carried out at $750^{\circ}C$ for 2.5 h. Based on microstructural examination, Intragranular polygonal ferrite and grainboundary ferrite were formed only in first layer of weld metal. Another layers consisted of acicular ferrite and $Widmannst{\ddot{a}}tten$ ferrite. The amount of acicular ferrite was increased with decreasing heat input and layer. Heat affected zone of alloy steel showed the highest hardness due to the formation of tempered martensite and lower bainite. Lower and upper bainite were formed in heat affected zone of carbon steel. Tensile strengths of dissimilar metal welds decreased with increasing heat inputs. Dissimilar metal welds showed a good hot cracking resistance due to the low HCS index below 4. The salt spray test of dissimilar metals welds showed that the weight loss rate by corrosion below 170 hours was decreased with increasing heat inputs due to the increase of the amount of acicular ferrite.

합금강(ASTM A387 Gr. 91) - 탄소강(ASTM A516 Gr.70) 이종금속의 FCA 다층 용접부 특성 평가 : Part. 1 (A Study of Characteristics on the Dissimilar Metals (Alloy Steel : A387 Gr. 91 - Carbon Steel : A516 Gr. 70) Welds Made with FCA Multiple Layer Welding : Part 1)

  • 신태우;장복수;고진현
    • Journal of Welding and Joining
    • /
    • 제34권3호
    • /
    • pp.61-68
    • /
    • 2016
  • Characteristics of dissimilar metal welds between alloy steel ASTM A387 Gr. 91 and carbon steel ASTM A516 Gr.70 made with Flux cored arc welding(FCAW) have been evaluated in terms of microstructure, mechanical strength, chemical analysis by EDS as well as corrosion test. Three heat inputs of 15.0, 22.5, 30.0kJ/cm were employed to make joints of dissimilar metals with E91T1-B9C wire. Post-weld heat treatment was carried out at $750^{\circ}C$ for 2.5 h. Based on microstructural examination, tempered martensite and lower bainite were formed in first layer of weld metal. The amount of tempered martensite was decreased and the amount of lower bainite was increased with increasing heat input and layer. Heat affected zone of alloy steel showed the highest hardness due to the formation of tempered Martensite and lower Bainite. Tensile strengths of dissimilar welds decreased with increasing heat inputs. Dissimilar welds seemed to have a good hot cracking resistance due to the low HCS index below 4. The salt spray test of dissimilar metals showed that the corrosion rate increased with increasing heat inputs due to the increase of the amount of lower Bainite.

플럭스 코어드 아크 용접의 아크현상과 스패터 발생량과의 관계 (Relation between Arc Phenomena and Spattering Ratio of Flux Cored Arc Welding with 100% $CO_2$ Shielding gas)

  • 강성원;엄동석;오은식;유덕상
    • 대한조선학회논문집
    • /
    • 제35권4호
    • /
    • pp.65-75
    • /
    • 1998
  • GMA 용접 중 100% $CO_2$ 가스를 사용하는 $CO_2$ 용접은 경제적이고 고능률적이라는 점 때문에 많이 사용되고 있다. $CO_2$ 용접의 아크현상과 스패터 발생량은 용접용 와이어의 화학성분, 실드가스, 용접조건 등에 영향을 받는다. 특히 용접조건은 용적이행 모드를 결정하기 때문에 스패터 발생량에 커다란 영향을 미친다. 본 연구는 $CO_2$ 용접 재료 중 두 type의 FCW(titania계, semi-metal계)를 이용하여 용접조건을 변화시켜 아크현상과 스패터 발생량을 파악하여 용접부의 품질 평가와 용접조건 설정에 기여코져 한다. 본 연구를 통해, 다음과 같은 결론을 얻을 수 있다. 1) 저전류 영역(140A)의 FCW 모두 22V까지는 전형적이 단락이행이 나타났고, 스패터 발생량의 증가와 저전류 스패터 입도를 대립화하였다. 2) 대전류 영역(320A)의 전형적인 globular이행에서 titania계 FCW가 semi-metal계 FCW보다 아크 안정성이 양호하였다.

  • PDF