Abstract
The $CO_2$ welding with 100% $CO_2$ gas is commonly used because of its cost and efficiency. Arc phenomena and spattering ratio of the $CO_2$ welding are influenced by various factors such as chemical compositions of welding wire, shielding gas, welding condition and welding power source etc.. Spattering ratio is predominantly influenced by the welding condition which determines a droplet transfer rode. In this study, arc phenomena and spattering ratio are investigated by using two type of FCW(titania type, semi-metal type). Then, the welding quality and optimum welding condition can be selected. From this study, the following results ware obtained; 1) In low current range(140A), FCW up to welding voltage(22V) resulted in a typical short circuit transfer, increase of spattering ratio and growth of spatter diameter. 2) In high current range(320A), the arc stability in titania FCW of a typical globular transfer is better than that of semi-metal FCW.
GMA 용접 중 100% $CO_2$ 가스를 사용하는 $CO_2$ 용접은 경제적이고 고능률적이라는 점 때문에 많이 사용되고 있다. $CO_2$ 용접의 아크현상과 스패터 발생량은 용접용 와이어의 화학성분, 실드가스, 용접조건 등에 영향을 받는다. 특히 용접조건은 용적이행 모드를 결정하기 때문에 스패터 발생량에 커다란 영향을 미친다. 본 연구는 $CO_2$ 용접 재료 중 두 type의 FCW(titania계, semi-metal계)를 이용하여 용접조건을 변화시켜 아크현상과 스패터 발생량을 파악하여 용접부의 품질 평가와 용접조건 설정에 기여코져 한다. 본 연구를 통해, 다음과 같은 결론을 얻을 수 있다. 1) 저전류 영역(140A)의 FCW 모두 22V까지는 전형적이 단락이행이 나타났고, 스패터 발생량의 증가와 저전류 스패터 입도를 대립화하였다. 2) 대전류 영역(320A)의 전형적인 globular이행에서 titania계 FCW가 semi-metal계 FCW보다 아크 안정성이 양호하였다.