• 제목/요약/키워드: Metal sample

검색결과 842건 처리시간 0.027초

Spectrometer for the Study of Angle-and Energy-Resolved Reactive Ion Scattering at Surfaces

  • S-J. Han;C.-W. Lee;C.-H. Hwang;K.-H. Lee;M. C. Yang;H. Kang
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.883-888
    • /
    • 2001
  • We describe an ion-surface scattering apparatus newly developed to investigate the reactive scattering process of low-energy alkali-metal ions at surfaces. The apparatus consists of an alkali-metal ion gun that is rotatable by 360°, a quadrupole mass spectrometer (QMS) with an ion energy analyzer, a sample manipulator with a heating-and-cooling stage, and an ultrahigh vacuum (UHV) chamber that houses these components. Preliminary experimental results obtained from the apparatus are presented on angular and energy distributions of the ions scattered from clean Pt(111) and water-adsorbed Pt surfaces.

Determination of Zinc and Lead in Water Samples by Solvent Sublation Using Ion Pairing of Metal-Naphthoate Complexes and Tetra-n-butylammonium Ion

  • 김영상;최윤석;이원;이용일
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.821-826
    • /
    • 2001
  • Solvent sublation has been studied for the separation and determination of trace Zn(Ⅱ) and Pb(Ⅱ) in water samples. A synergy producing method was utilized to improve the efficiency of extraction in the sublation using an ion-pair of metal-naphth oate {M-(Nph)3- } complexes and tetra-n-butylammonium (TBA+ ) ion. After the M-(Nph)3- complexes were formed by adding 1-naphthoic acid to the sample solution, tetra-n-butylammonium bromide was added in the solution to form the ion-pair. And sodium lauryl sulfate (SLS) was added to make the ion-pair hydrophobic. The ion-pairs of the metal complexes were floated and extracted into methylisobutyl ketone (MIBK) from the aqueous solution by bubbling with nitrogen gas in a flotation cell. Metal ions in MIBK solution were measured by graphite furnace-AAS. Experimental conditions were optimized as follow so. After the pH of a 1.0 L water sample was adjusted to 5.0, 6.0 mL of 0.1 M 1-HNph and 10 mL of 0.03 M TBA-bromide were added to the sample to form ion-pairs, and 2.0 mL of 0.2%(w/v) SLS was added to make the ion-pairs hydrophobic. The solution was bubbled with 30 mL/min N2 gas for 5 minutes in a flotation cell. Linear calibration curves were obtained for the determination of Zn(Ⅱ) and Pb(Ⅱ) in several water samples. Reproducible results of showing a relative standard deviation of < 10% and recoveries of 80-100% could be obtained.

실리콘 웨이퍼 중의 금속 불순물 분석을 위한 시료 전처리 (Sample Pretreatment for the Determination of Metal Impurities in Silicon Wafer)

  • 정혜영;김영훈;유학도;이상학
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.412-417
    • /
    • 1999
  • 실리콘 웨이퍼 중의 금속 불순물을 유도결합플라스마-질량분석기(ICP-MS)로 분석하기 위한 시료의 전처리 방법으로 마이크로파 분해법과 산분해법을 비교하였다 $HNO_3$-HF 혼합용액을 실리콘 웨이퍼 시료에 가하고 마이크로파 분해법과 산분해법으로 용해시킨 후, 용액의 실리콘 매트릭스는 증발 용기 안에서 Si-F의 형태로 증발시켜 분석하였다. 실제 시료에 spike한 Ni, Cr 및 Fe의 회수율은 두 전처리 방법에서 95∼106%였다. Cu의 경우는 산분해법이 회수율이 더 좋았고, Zn의 경우는 마이크로파 분해법으로 전처리 한 경우의 회수율이 더 좋았다. Spin coater로 Fe를 오염시킨 실리콘 웨이퍼를 산분해법과 마이크로파 분해법으로 전처리하여 ICP-MS로 분석한 결과, Fe의 농도는 위의 두 전처리 방법에서 거의 차이가 없었다.

  • PDF

Preparation and Properties of Waterborne Poly(urethane-urea) Ionomers -Effect of the Type of Neutralizing Agent-

  • Yang, Jung-Eun;Lee, Young-Hee;Koo, Young-Seok;Jung, Young-Jin;Kim, Han-Do
    • Fibers and Polymers
    • /
    • 제3권3호
    • /
    • pp.97-102
    • /
    • 2002
  • A series of waterbome poly(urethane-urea) anionomers were prepared from isophorone diisocyanate (IPDI), polycaprolactone diol (PCL), dimethylol propionic acid (DMPA), ethylene diamine (EDA), and triethylamine (TEA), NaOH, or Cu($(COOCH_3)_2$) as neutralizing agent. This study was performed to decide the effect of neutralizing agent type on the particle size viscosity, hydrogen bonding index, adhesive strength, antistaticity, antibacterial and mechanical properties. The particle size of the dispersions decreased in the following order: TEA based samples (T-sample), NaOH based samples (N-sample), and Cu($(COOCH_3)_2$) based sample (C-sample). The viscosity of the dispersions increased in the order of C-sample, N-sample, and T-sample. Metal salt based film samples Of and C-sample) had much higher antistaticity than TEA based sample. By infrared spectroscopy, it was found that the hydrogen bonding index (or fraction) of samples decreased in the order of T-sam-pie, N-sample, and C-sample. The adhesive strength and tensile modulus/strength decreased in the order of T-sample, N-sam-pie, and C-sample. The C-sample had strong antibacterial halo, however, T- and N-samples did not

Influence of metal annealing deposited on oxide layer

  • Kim, Eung-Soo;Cho, Won-Ju;Kwon, Hyuk-Choon;Kang, Shin-Won
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.365-368
    • /
    • 2002
  • We investigated the influence of RTP annealing of multi-layered metal films deposited on oxides layer. Two types of oxides, BPSG and P-7205, were used as a bottom layer under multi-layered metal film. The bonding was not good in metal/BPSG/Si samples because adhesion between metal layer and BPSG oxide layer was poor by interfacial reaction during RTP annealing above 650$^{\circ}C$. On the other hand bonding was always good in metal/ P-TEOS /Si samples regardless of annealing temperature. We observed the interface between oxide and metal layers using AES and TEM. The phosphorus and oxygen profile in interface between metal and oxide layers were different in metal/BPSG/Si and metal/P-TEOS/Si samples. We have known that the properties of interface was improved in metal/BPSG/Si samples when the sample was annealed below 650$^{\circ}C$.

  • PDF

국내 유통 한약재의 중금속 함량 모니터링 -서울과 대구지역 한약재 중심으로 - (Monitoring of Heavy Metal Contents in Commercial Herbal Medicines in Korea: Cultivated Herbal Medicines in the Seoul and Daegu Areas)

  • 장설;이아름;이아영;최고야;김호경
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.30-39
    • /
    • 2015
  • Objectives: This study was conducted to determine the heavy metal contents in commercial herbal medicines in Korea. Methods: Monitoring of lead, arsenic, cadmium and mercury was carried out on 116 samples of eleven types of herbal medicines. Among the total samples, 71 samples were domestic and 45 were imported. The samples were digested using the microwave method. The heavy metal contents were measured by inductively coupled plasma atomic emission spectrometry (ICP-AES) and a mercury analyzer. ICP-AES was used to analyze lead, arsenic cadmium. Mercury was analyzed by the amalgamation method. Results: The mean values of the heavy metal contents in the herbal medicines were Pb 0.64mg/kg, As 0.26mg/kg, Cd 0.07mg/kg and Hg 0.004mg/kg. Of the total samples, one violated the MFDS (Ministry of Food and Drug Safety) regulatory guidance on heavy metals in herbal medicines. Lead was detected at more than 5mg/kg in one sample. The measured values of arsenic, cadmium and mercury in the herbal medicines showed levels lower than the recommended levels for herbal medicines in MFDS regulatory guidance. In the comparison of domestic samples with imported herbal medicines, it was found that one domestic sample surpassed the maximum residue limits for lead. Conclusion: These results will be used to establish the regulation and control of heavy metal contents in herbal medicines. In addition, continuous monitoring is needed to ensure confidence in and the safety of these herbal medicines.

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

  • Kim Yong-Sun;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.275-283
    • /
    • 2006
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were $88{\pm}10{\mu}m$ for the control (metal-ceramic crowns), $92{\pm}4{\mu}m$ for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

중금속과 체류시간이 산업단지하수 질산화에 미치는 영향 (Analysis on effect of heavy metal and Retention time to nitrification using industrial wastewater)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제20권4호
    • /
    • pp.390-397
    • /
    • 2018
  • 산업단지 인근에 위치한 하수처리장은 유입되는 산업폐수 내 중금속으로 인해 질산화 효율이 감소하는 문제점이 있다. 본 연구에서는 실험실 규모 반응조 운전 결과를 바탕으로 산업폐수가 유입되는 하수처리장의 질산화 효율 개선을 위해 중금속과 체류시간이 질산화에 미치는 영향을 분석하였다. 또한 운전 결과를 바탕으로 질산화율 향상을 위한 하수처리장 운전 방법을 제시하고자 한다. 실험실 반응조 운전 결과 체류시간 0.5일 이상으로 운전 할 경우 60% 이상의 질산화율을 확보할 수 있을 것으로 나타났다. 하지만, 동일한 조건에서 일반 도시하수처리장 시료를 이용하는 경우보다 낮은 효율을 보이는 것으로 조사되었다. 이와 같은 결과를 보인 원인으로 산업 폐수 내 함유된 중금속의 영향으로 질산화 미생물의 활성(SNR 기준)을 분석하였다. S 하수처리장과 일반 하수처리장 시료(A MWTPame )를 이용한 반응조의 SNR은 각각 0.13 ~ 0.21 mg NH4/gMLSS/hr과 0.74 mg NH4/gMLSS/hr의 범위를 보였다. 이는 S 하수처리장 시료를 유입수로 하는 반응조 내 미생물의 활성이 낮음을 확인 할 수 있다. 따라서 산업폐수가 유입되는 하수처리장에서 질산화 효율개선을 위해 체류시간 증가 및 전처리를 통한 중금속 처리가 필요할 것으로 판단된다.

Montmorillonite가 섞인 천연 제올라이트를 이용한 중금속 이온의 제거 (Removal of Heavy Metal Ions by Using Natural Zeolite Comixed with Montmorillonite)

  • 문정호;김윤호;김영만;김천한;곽현태
    • 분석과학
    • /
    • 제13권3호
    • /
    • pp.394-398
    • /
    • 2000
  • The mineralogical properties of natural zeolite comixed with montmorillonite were investigated by the chemical composition analysis, X-ray diffraction analysis, and differential scanning calorimetry. The experimental results on the removal of heavy metal ions by using the natural sample are summerized as follows. The removal of the heavy metal in solution is greatly influenced by the pH. Also, the removal capacity of heavy metal ions by zeolite and montmorillonite have increased in order of $Cu^{2+}>Cd^{2+}>Ni^{2+}$.

  • PDF

연소법 전처리에 의한 고분자 물질 중 중금속의 분석 (Analysis of heavy metal in polymer materials by combustion ICP-AES Method)

  • 임헌성;이보름;이석근
    • 분석과학
    • /
    • 제23권6호
    • /
    • pp.615-618
    • /
    • 2010
  • An oxygen bomb combustion procedure were studied for determination of heavy metal in polymer materials such as polyvinyl chloride and polypropylene by ICP-AES. This method is proposed as a rapid and simple sample preparation for decomposition of polymer containing certified contents of the analytes by teflon coated oxygen bomb combustion using different absorbing solution. The recoveries of metal were found to be 30~102% from absorbed solution by ICP-AES method using polypropylene certified reference material(PP CRM-As, Ba, Cd, Hg, Pb, Zn). The recoveries of metal using PVC CRM(Cd, Hg, Pb) was found to be 45 ~101% with same procedures.