• Title/Summary/Keyword: Metal sample

Search Result 842, Processing Time 0.024 seconds

A Study of Bond Strength of Nickel-Chromium Alloys with Porcelain in Ceramometal System (상이(霜異)한 Ceramometal System에 있어서 Nickel-Chromium합금과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 비교실험연구(比較實驗硏究))

  • Kim, Chee-Young
    • Journal of Technologic Dentistry
    • /
    • v.7 no.1
    • /
    • pp.19-25
    • /
    • 1985
  • In oder to compare and measure bond strength of ceramometal system with use of ceramco porcelain powder including SnO2 and uni metal, Rexillium III, Vera Bond as non precious alloys manufactured for porecelain-metal restorations. Total 24 test sample were constructed. All Test sample were measured with a Mitutoyo micrometer graduated to 0.01mm. It is as follows measured of thickness 3.3mm(metal : 1.1mm, porcelain: 2.2mm), width 12mm, length 30mm(porcelain 12mm x 12mm), Compared maximum bending stress test. The results obtained were as follows: 1. Bond strength of each metal with ceramco porcelain powder showed statistical significance.(P<0.05) 2. Vera Bond and uni metal, uni metal and Rexillium III revealed no statistical Significance.(P>0.05) Vera Bond and Rexillium III showed statistical significance.(P<0.05) 3. The order of maximum bending stress was Rexillium III, uni metal, vera Bond. The order of bond strength ratio making bending stress was Vera bond, uni metal, Rexillium III.

  • PDF

Effect of Zirconia Core Thickness on the Tone Blocking of Discolored Tooth and Metal Post (지르코니아 코어의 두께에 따른 변색치와 메탈 포스트의 색조차단 효과)

  • O, Seon-Mi;Lee, Chae-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.327-335
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the correlation between zirconia core thickness and color tone blocking of discolored tooth and metal post. Methods: For this study, we made 20-porcelain sample and 4-metal sample( liechtenstein IPS e.max) bonded to zirconia core of different thickness with cement(Relyx ARC-3M USA)for produce discolored. We measured the color-spectral characteristics, using Shadepilot equipment(Degudent USA).We measured it with Shadepilot equipment set by automated average mode in 3 times And applied the average value obtained from 2 times of measurement in the middle of each sample. Results: As a result of analysing color-spectral characteristics on zirconia core sample, Depending on the thickness of zirconia core, the value of brightness(${\Delta}L*$:color-spectral characteristic) was increased within limited range, value of ${\Delta}a*$, ${\Delta}b*$ was decrease. Conclusion: Consequently, we obtained the following results: Changes of sample color were observed depending on the thickness of zirconia, but the range of change did not exceed the scope range of shade guide. The case of metal posts, shade guide color D2 were observed in 0.5mm of zirconia core thickness. As a result, in case of porcelain, increasing the zirconia thickness of 0.3mm or more is unnecessary for color blocking effect, in case of metal post, considering the discolored tooth, thickness of zirconia with at least 0.5mm or more is recommended.

Annealing for Improving adhesion between Metal layer and Oxide layer (산화막과 금속박막 계면에서의 adhesion 개선을 위한 열처리)

  • 김응수
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.225-228
    • /
    • 2002
  • The adhesion effect between the oxide layer and the metal layer has been studied by RTP anneal. Two types of oxides, BPSG and P-TEOS, were used as a bottom layer under multi-layered metal film. We observe the interface between oxide and metal layer using SEM (scanning electron microscopy), TEM (transmission electron microscopy), AES (auger electron spectroscopy). Adhesion failure was occurred by interfacial reaction between the BPSG oxide and the multi-layered metal film at 650"C RTP anneal. The phosphorus rich layer was observed at interface between BPSG oxide and metal layer by AES and TEM measurements. On the other hand adhesion was a)ways good in the sample used P-TEOS oxide as a bottom layer. We have known that adhesion between BPSG and multi-layered metal film was improved when the sample was annealed below $650^{\circ}C$.TEX>.

  • PDF

Isotachophoretically Assisted On-Line Complexation of Trace Metal Ions in a Highly Saline Matrix for Capillary Electrophoresis

  • Kim, Ji-Hye;Choi, Ki-Hwan;Cho, Sun-Young;Riaz, Asif;Chung, Doo-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.790-794
    • /
    • 2012
  • Trace metal ions such as $Cd^{2+}$, $Ni^{2+}$, and $Zn^{2+}$ in a highly saline sample were subjected to on-line complexation with 4-(2-thiazolylazo) resorcinol (TAR) dissolved in a background electrolyte (BGE) under transient isotachophoresis (TITP) conditions. A long plug of the saline sample, containing the trace metal ions but devoid of TAR, was injected into a coated capillary filled with a BGE composed of 150 mM 2-(cyclohexylamino) ethanesulfonic acid (CHES) and 110 mM triethylamine (TEA) at pH 9.7. Since the electrophoretic mobility of TAR fell between the mobilities of the anionic leading electrolyte ($Cl^-$ in the sample) and the anionic terminating background electrolyte ($CHES^-$), a highly concentrated zone of TAR from the BGE was formed at the rear of the sample matrix and then the metal cations toward the cathode were swept by isotachophoretically assisted on-line complexation (IAOC) between the metal ions and the isotachophoretically stacked TAR. As a result, anionic metal-TAR complexes were formed efficiently, which satisfy the TITP conditions between $Cl^-$ and $CHES^-$. The enrichment factors of metal ions including $Cd^{2+}$ were up to 780-fold compared to a conventional CZE mode using absorbance detection. The detection limits were 17 nM, 15 nM, and 27 nM for $Ni^{2+}$, $Zn^{2+}$, and $Cd^{2+}$ in a 250 mM NaCl matrix, respectively. Our method was successfully applied to the analysis of urine samples without desalting.

Adsorption of Hg(I), Pb(II), and U(VI) ions using from Fruits of Schizandra Chinensis (오미자를 이용한 Hg(I), Pb(II), U(VI) 이온들의 흡착)

  • Kim, Kwan-Chun;Kim, Joon-Tae
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.1 s.63
    • /
    • pp.29-35
    • /
    • 2007
  • This study was examined adsorption ability of heavy metal Hg(I), Pb(II), and U(Vl) ion use of fruit from schizandra chinensis, The fruits of schizandra chinensis sample used breaking into fragments $50{\sim}100$ mesh. The sample solution was mixed fruits of schizandra chinensis and heavy metal ion. Each heavy metal ion of into solution was quantum analysis with ICP-AES. As the result, each condition of maxium adsorption ability of heavy metal ion was high in the range of pH 5-7, adsorption time was about 15 minutes, and the optimum temperature was $100^{\circ}C$. The heavy metal ion was increased adsorption in order of increasing concentration and in ethanol solution better than in aqueous solution.

The Application of Surfactants to the Suppression of Fugitive Dust Generated from the Scrap Metal Loading Field in Inchon Port and Preliminary Evaluation on Their Wetting Capability (인천항 고철 하역 작업시 발생하는 비산분진 억제를 위한 계면활성제의 적용 및 기초 성능 평가)

  • Lee, Bo-Young;Yoo, Yong-Ho;Jung, Yong-Won;Kim, Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.85-96
    • /
    • 2001
  • The objective of this study is to develop the water spraying which can effectively by applied to the control or suppression of the fugitive dust generated from the scrap metal handling area at the Port of Inchon. As a first step toward this goal, we carried out some preliminary analyses on the chemical composition, physical shape, and particle size distribution of the sample dust. Next, to quantitatively investigate the effect of adding surfactants to the spraying water on the wettability of the sample dust, the Standard Sink Test was carried out for four different surfactants and at six different concentrations using the surfactants considered in this study. Results of from the preliminary analysis indicated that the main chemical component consisting of the sample dust is Goethite(FeO(OH)) and that the particles smaller than 10 ${\mu}{\textrm}{m}$ in geometric diameter occupy about 36% of the sample dust in mass. This result implies that the fugitive dust generated from the scrap metal handling area at the Port of Inchon should affect the environment nearby more than we have expected. This is because of relatively large mass percentage of the small metal particles less than 10${\mu}{\textrm}{m}$ in geometric diameter, what we may call respirable particles. As for the results of the Standard Sink Test, higher surfactant concentration tends to result in the higher wettability of the sample dust for the surfactants considered in this study, which in turn ensures the high particle collection efficiency of the droplets generated from the water spraying system. Based upon this preliminary results, studies to develop more sophisticated scaled model for dynamic test in underway and the effort to find the best surfactants as well as the optimum operating conditions are being made at the same time.

  • PDF

표준시료를 이용한 토양중 중금속 분석방법 비교

  • Yun Jeong-Gi;Kim Tae-Seung;Kim Dong-Ho;Jeon Seong-Hwan;Jeong Il-Rok;Kim Hyeok
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.242-246
    • /
    • 2005
  • The heavy metal analysis (Cd, Pb, Cu, Cr, Zn, Ni) with various extraction methods was performed using the certified sample and real soil sample. In case of the certified samples, $10.5{\sim}118%$ of recovery was showed with various ranges depend on the metal kinds and extraction methods. Also, the alkali-digestion method was showed the proper results by applying in hexavalent chromium. In case of real sample, compared to amounts of heavy metals extracted using 0.1N-HCl, those extracted using acid digestion are higher by $3{\sim}24$ times in Cu, $1.1{\sim}1.5$ times in Cd, $2{\sim}23$ times in Pb, $3{\sim}104$ times in Zn, $12{\sim}101$ times in Ni, $30{\sim}202$ times in Cr. There is no considerable difference between four acid digestion methods.

  • PDF

Specimen Preparation for Scanning Electron Microscope Using a Converted Sample Stage

  • Kim, Hyelan;Kim, Hyo-Sik;Yu, Seungmin;Bae, Tae-Sung
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.214-217
    • /
    • 2015
  • This study introduces metal coating as an effective sample preparation method to remove charge-up caused by the shadow effect during field emission scanning electron microscope (FE-SEM) analysis of dynamic structured samples. During a FE-SEM analysis, charge-up occurs when the primary electrons (input electrons) that scan the specimens are not equal to the output electrons (secondary electrons, backscattered electrons, auger electrons, etc.) generated from the specimens. To remove charge-up, a metal layer of Pt, Au or Pd is applied on the surface of the sample. However, in some cases, charge-up still occurs due to the shadow effect. This study developed a coating method that effectively removes charge-up. By creating a converted sample stage capable of simultaneous tilt and rotation, the shadow effect was successfully removed, and image data without charge-up were obtained.

Evaluation of a metal level in non-precious metal alloys dental casting having beryllium by lactic acid Solution (베릴륨함유 치과 주조용 비귀금속 합금의 젖산용액에 의한 금속 노출수준 평가)

  • Park, Soo-Chul;Jang, Eun-Jin;Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the level of each metal in non-precious metal alloys dental casting, still used even banned for use and trade by the law, for oral health. Methods: Two kinds of metal alloys were analyzed. One was Ticonium 100 for removable prosthesis and the other was Rexillium V for dental porcelain. Two samples of each metal alloy were made in 0.5g, 1.0g, and 1.5g. Total number of samples were 12. Two kinds of lactic acid Solution, pH7 and pH4.6, were injected into each samples. After injection, each samples had been for 21days ${\pm}$ 1 hour in the water tank of which temperature was $37^{\circ}C$. The level of metal was measured in each sample by inductively couplled plasma-atomic emission spectrometer. Results: In both metal alloys, metals, chrome, nickel, beryllium, and molybdenum, were founded. In Ticonium 1000, the highest level of nickel was 2.531ppm in 1.5g pH4.6 sample while the highest level of nickel was 4.062ppm in 1.5g pH4.6 sample of Rexillium V. In chemical composition of these methal alloys, chrome(14~17%) was much more than beryllium(1.95~1.99%) and molybdenum(5.0~9.0%) but berllium and molybdenum were founded more than chrome in samples. Therefore, chrome showed better anti-corrosion than other metal alloys. In both metal alloys, more metals were founded in higher pH level and more mass. Levels of chrome was significantly different in samples of both metal alloys in each pH level(p<0.05). Levels of nickels was significantly different in samples of both metal alloys in each pH level(p<0.05). Conclusion: For oral health, further studies are needed in nickel-chrome metal alloy and cobalt metal alloy of non-beryllium in addittion to beryllium metal alloy and also long-term studies needed in various period and other non-percious metal alloys for dental casting.

THE PROBLEMS IN THE USUAL METHOD OF CLASSIFICATION FOR METAL POOR STARS

  • Lee, Sang-Gak
    • Journal of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.173-181
    • /
    • 1988
  • The usual method of classification for metal poor stars is based on the normal standard stars. In this study, we show that among the sample of stars classified by this method, a systematic bias in the observed classes of metal weakness is found and, also that this method is not appropriate for classification of metal poor stars, by showing that the spectral line dependences on the temperature and pressure in the extreme metal poor stars are different from those in the normal standard stars. Therefore, we suggest that the 3-dimensional classification system, like 2-dimensional MK system, is necessary for an accurate classification of metal poor stars.

  • PDF