• Title/Summary/Keyword: Metal point

Search Result 1,071, Processing Time 0.028 seconds

Peroneal Artery Perforator Free Flap on the Palm and Removal of Back Foreign Body in High Voltage Electrical Burn Patient: A Case Report (고압전기화상 환자에서 손바닥에 비골동맥천공지유리피판수술과 등의 이물질제거수술: 증례 보고)

  • Jung, Sung Won;Lee, Seung Je
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.58-65
    • /
    • 2019
  • Wound caused by high-tension electrical burns is difficult to manage because the wound is deep and complex. The wound is progressively necrotic due to microvascular injury resulting in deep tissue exposure. So, coverage of the wound at the entry point and the exit point is cumbersome, often requiring flap coverage. We experienced a case of one patient for peroneal artery perforator free flap coverage on the palm of the right hand of the entry point of electrical burn. The left foot wound of electrical exit point was covered by full thickness skin graft. Also a small wound was on the left side of the lower back was the exit point of electrical burn. The lower back wound was healed and recurred repeatedly after burn. On postburn day 6 month, through the radiologic exam, metal shadow was identified in the left gluteus muscle forming chronic sinus. We explored the wound of sinus and a foreign body was identified in the sac as multi braid wires thin as hair. According to the patient's past history, we suspected that the back wound was caused by electrical burn injury through the wires.

Study on the Nucleation of Liquid Metal in Solidification (액체금속의 응고에서 핵생성에 관한연구 -Bi 용탕의 핵생성에 미치는 초음파진동의 영향에 대하여-)

  • ;;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.2
    • /
    • pp.113-124
    • /
    • 1977
  • By spplying the ultrasomic wave to the solidifing liquid metal, grain sizes of the ingot are refined and the structures are homogenized. One of the reason is the enhancement of nucleation by ultrasonic vibration. According to the reports on this subject, the uncleating conditions are formed by the increse of melting point which is produced by the high pressure due to caviation. In this paper we study whether the caviations are the orgin of the nucleation and analized whether the nucleating conditions are formed by the increase of melting point or not and also compared the analytical result with the experim nt. We analized the pressure change induced by cllaphsing of cavity and the motion of cavith in oscillating pressure field. And we further analized the variation of melting point with pressure change.

A Study on the Relation between Riverbed Structure and Pollutant Concentration in Downstream of Nakdong River (낙동강 하류의 하상구조와 오염물질과의 상관관계 연구)

  • 황선출;정성욱
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.481-494
    • /
    • 1996
  • This study was performed to investigate the relationship between concentrations of heavy metals in sediment and the depths of 27 sampling sites along the West Nakdong river in downstream of Nakdong River. The deepest site was Kangdong bridge nearby 20ft. From here, the depth was shallowed to Chidong gradually. In each site the smaller mesh was, the liger concentration of heavy metal becomed. Concentration of Zn, Cd, Cr and Cu at inflow point of Shinoe stream was 576.016 ppm, 262.307 ppm, 68.674 ppm and 61.634 ppm, respectively, the concentration was the higest at this point. From here, it was lowered gradually. The concentration of heavy metal at inflow point of Joman river was 155.328 ppm, 56.485 ppm, 25.200 ppm and 31.172 ppm, respectively, those concentrations were liger than other points with the exception of Shinoe stream. Therefore, woman river and Shinoe stream were the major source of pollution in West Nakdong river. Among two sources Shinoe stream was more important source of pollution. West Nakdong river has become lake by Noksan floodgate because it's pollution has had influence on Bonglim.

  • PDF

EXPERIMENTAL STUDY ON PROBABILITY OF STRENGTH FOR EPOXY ADHESIVE-BONDED METALS

  • Seo, Do-Won;Lim, Jae-Kyoo;Jeon, Yang-Bae;Yoon, Ho-Cheol
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.688-693
    • /
    • 2002
  • Adhesive bonding is becoming one of the popular joining techniques in metal industries, since it has some advantages over other techniques such as welding and diffusion bonding, e.g., any dissimilar metals are easily adhesive-bonded together. In this study, the experiments were carried out in order to provide the statistical data with strength evaluation methods: tension, shear and four-point bending tests for thermoplastic epoxy resin based adhesive-bonded metal joints. We should certificate on the probability of the adhesive strength that has the tendency of brittle fracture, the adhesive bonding strength between metals with thermoplastic adhesive has the best probability at four-point bending test. The strength testing method that has higher probability is four-point bending test, shear test and tensile test in order.

  • PDF

Analysis of Switching Overvoltage in 345kV Underground and Combined Transmission Systems (345kV 지중 및 혼합 송전계통에서의 개폐 과전압 해석)

  • 정채균;이종범;강지원
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.713-721
    • /
    • 2003
  • This paper analyzes the switching overvoltage occurred on 345kV underground power cable system as well as combined transmission system using EMTP. Cable length and closing time, preinsertion resistance have effect on switching overvoltage. Therefore, this paper analyzes the switching overvoltage occurred on conductor and sheath with change of those parameters. Specially, the cross bonding position becomes discontinuity point because of the difference between surge impedance of metal sheath and that of lead cable. Thus, the transmission and the reflection of traveling wave complexly occur at this connection point. According to these influences, voltage between sheath and earth as well as voltage between joint boxes rise. Time to crest point of switching overvoltage is longer than lightning overvoltage. Even though the voltage induced by switching surge is smaller than lightning surge, that voltage may have serious effect on the metal sheath. Therefore, this paper also analyses the reduction effect of switching overvoltage when the preinsertion resistance of circuit breaker is considered.

Microstructure and Mechanical Properties of Gas Metal Arc Brazed Joint of DP Steel with Cu-Si Filler Metal (Cu-Si 삽입금속을 이용한 DP강의 MIG 아크 브레이징 접합부의 미세조직과 기계적 성질)

  • Cho, Wook-Je;Yoon, Tae-Jin;Kwak, Sung-Yun;Lee, Jae-Hyeong;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.70-76
    • /
    • 2016
  • In this study, Microstructure and tensile properties in arc brazed joints of 1000MPa grade DP steel using Cu-Si insert metal were investigated. The fusion zone was composed of Cu phase which solidified a little Fe and Si. The former phase formed due to dilute the edge of base material by arc, although Fe was not solid solution in Cu at the room temperature. Cu3Si particles formed by crystallization at $1100^{\circ}C$ during faster cooling. After the tensile shear test, there are no differences between the brazed joint efficiencies. The maximum joint efficient was about 37% compared to strength of base metal. It is better than that of arc brazed joint of DP steel using Cu-Sn filler metal. Fracture position of all brazing conditions was in the fusion zone. Crack initiation occurred at three junction point which was a stress singularity point of upper sheet, lower sheet and the fusion zone. And then crack propagated across the fusion zone. The reason why the fracture occurred at fusion zone was that the hardness of fusion zone was lower than that of base material and heat affected zone. The correlation among maximum load and hardness of fusion zone and EST at fractured position was $R^2=0.9338$. Therefore, this means that hardness and EST can have great impact on maximum load.

A Study on effect that position of contact area at adjacent side has on fractures of porcelains in case of porcelain fused to metal crown (금속 소부 도재관의 경우 인접면에서 접촉점의 위치가 도재 파절에 미치는 영향에 관한 연구)

  • Kim, Yong-Won
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.173-180
    • /
    • 2007
  • There was a great problem about the deposition between materials of a different kind at the beginnings of the introduction of porcelains, however, thereafter the deposition efficiency was settlded to the sufficient level of all user thanks to effort to have studied by many scholars and clinical authorities. But in a clinical process, as the difference of designs has an effect on fractures of porcelains, this researcher divided them into 4 groups of A: 1 mm, B: 2 mm, C: 3 mm, and D: 4 mm, and made 40 pieces to each 10 as the test samples to consider a length axis of tooth for studies in accordance with a position of a finishing line to meet between porcelain and metal at the contact point at the adjacent side to a metal porcelain. The sample materials are those to be use at the open market and the test samples wer completed by the same manufacturing technique to that of existent metal porcelain tube. s a result of the strength test on fractures, the average value is as in the following, A: 1 mm - 8.5bar, B: 2 mm - 10.5bar, C: 3 mm - 14.3bar, and D: 4 mm - 15.0bar. In case of the metal porcelain tube, the more faraway to process parts of metal and porcelain from the contact point of adjacent side has the stronger strength of fractures, Accordingly, the research shows that it had better to keep off more than 3 to consider a ledngth axis of tooth.

  • PDF

Preparation of EMI Shielding Sheet by PVD Method and Its Characteristic of EMI Shielding Efficiency (PVD법을 이용한 전자파 차폐용 시트 제조 및 차폐효율 특성)

  • Chae, Seong-Jeong;Hong, Byung-Pyo;Lee, Byoung-Soo;Byun, Hong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.527-531
    • /
    • 2010
  • The optimized sheet for EMI shielding was prepared by metal power with Fe series. Then various metal powders were deposited on the sheet by PVD method. Moreover, the PVdF nanofiber membrane was used to compare the characteristic of EMI shielding efficiency of various metal powders. The electrical property was measured by the 4-point probe method. The result from EDS confirmed that the metal powder existed on the sheet. EMI shielding efficiency was analysed by EMI shielding measurement apparatus. The lowest electrical resistance, $641.95{\Omega}{wcdot}cm$, was obtained with $1000\;{\AA}$ deposition of Cu on the sheet. It was revealed that the EMI shielding efficiency increased with increase of the metal deposition thickness. The sheet deposited by Cu with $1000\;{\AA}$ showed the highest EMI shielding efficiency, 32.5 dB.

Aluminum Brazing and Its Principle (알루미늄의 브레이징과 원리)

  • Lee, Soon-Jae;Jung, Do-Hyun;Jung, Jae-Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • Aluminum alloys have been widely used in many fields such as electronic, structure, aero-space and vehicle industries due to their outstanding thermal and electrical conductivity as well as low cost. However, they have some difficulties for using in brazing process because of the strong oxide layer of $Al_2O_3$ on the surface of Al alloy. In addition, their melting point is similar to that of brazing filler metal resulting in thermal damage of Al alloys. Therefore, it is very important to understand the brazing principles, filler metal and its properties such as wetting, capillary flow and dissolution of base metal in the Al brazing process. This paper reviews the brazing principles, aluminum alloys, and brazing fillers. In the case of brazing principle, some formula was used for calculation of capillary force and the dissolution to obtain the best condition of Al brazing. In addition, the advanced research trends in Al brazing were introduced including thermal treatment, additive for improving property and decreasing melting point in Al brazing process.

Ceramic and stainless steel brazing by active filler metal (활성 용가재를 이용한 세라믹 및 스테인레스강의 접합)

  • 김원배;김숙환;권영각;장래웅;배석천
    • Journal of Welding and Joining
    • /
    • v.9 no.4
    • /
    • pp.17-27
    • /
    • 1991
  • The direct brazing technology which could be used for the simplification of brazing process and the improvement of brazed joint quality was studied with $Al_2O_3$ and stainless steels. The brazing of $Al_2O_3$ to STS304 or STS430 was performed under different brazing conditions such as brazing filler metal, temperature, heating rate and brazing time. Microstructural observation and chemical analysis be SEM/EPAM were carried out to verify the quality of brazed joints. 4-point bending strength of brazed joints was also measured to find the optimal brazing conditions. The results showed that, in brazing of $Al_2O_3$, the mixed oxide layer resulted from the reaction between Ti in filler metal and oxide layer on the material surface to be brazed was found to be bery important for the joint quality. The width of oxide layer varied with the brazing conditions such as brazing time, heating rate and chemical composition of filler metals. The strength of brazed joints was more affected by the type of materials and their thermal properties than by brazing heat cycle.

  • PDF