Study on the Optimization of Parameters for Burring Process Using 980MPa Hot-rolled Thick Sheet Metal (980MPa급 열연 후판재 버링 공정의 변수 최적화 연구)

  • Kim, S.H.;Do, D.T.;Park, J.K.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.30 no.6
    • /
    • pp.291-300
    • /
    • 2021
  • Currently, starting with electric vehicles, the application of ultra-high-strength steel sheets and light metals has expanded to improve mileage by reducing vehicle weight. At a time when internal combustion engine vehicles are rapidly changing to electric vehicles, the application of ultra-high-strength steel is expanding to satisfy both weight reductions and the performance safety of the chassis parts. There is an urgent need to improve the quality of parts without defects. It is particularly difficult to estimate the part formability through the finite element method (FEM) in the burring operation, so product design has been based on the hole expansion ratio (HER) and experience. In this study, design of experiment (DOE), analysis of variance (ANOVA), and regression analysis were combined to optimize the formability by adjusting the process variables affecting the burring formability of ultra-high-strength steel parts. The optimal variables were derived by analyzing the influence of variables and the correlation between the variables through FE analysis. Finally, the optimized process parameters were verified by comparing experiment with simulation. As for the main influence of each process variable, the initial hole diameter of the piercing process and the shape height of the preforming process had the greatest effects on burring formability, while the effect of a lower round of punching in the burring process was the least. Moreover, as the diameter of the initial hole increased, the thickness reduction rate in the burring part decreased, and the final burring height increased as the shape height during preforming increased.

Level of Blood Lead and Urine Cotinine of Residents by Area (지역 특성에 따른 주민의 혈중 Pb 농도와 요중 Cotinine의 농도)

  • Oh, Yu-Jin;Kim, Hyoung-Wook;Kim, Yun-Jae;Han, Yoon-Deok;Jung, Sung-Hyeon;Lee, Jong-Dae;Jang, Bong-Ki;Lee, Jin-Heon;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.28 no.3
    • /
    • pp.329-339
    • /
    • 2019
  • The National Institute of Environmental Research (3rd KONEHs) conducted a survey of 280 residents in Ulsan, Suwon and Asan, and the concentration of heavy metals in the blood and urine were also analyzed. In case of blood lead concentration, Ulsan $2.27{\mu}g/dl$, Suwon $2.08{\mu}g/dl$, and Asan $1.75{\mu}g/dl$, the high peak in Ulsan, and the low peak in Asan. In case of cotinine concentration, Ulsan smoking($609.16{\mu}g/g{\_}ct$) is higher than nonsmoking($74.07{\mu}g/g{\_}ct$), as Suwon and Asan smoking($416.72{\mu}g/g{\_}ct$, $903.21{\mu}g/g{\_}ct$) is higher than nonsmoking($72.72{\mu}g/g{\_}ct$, $18.06{\mu}g/g{\_}ct$), smoking group is higher than nonsmoking group in all areas revealed statistically significant correlation(p<0.01). In considering results synthetically, these study results are an aid to constructing environmental health science-side heavy metal management measure education programs for normal residents.

A study on the mold opening stroke according to the control method of the injection molding machine (사출성형기의 속도제어 방식에 따른 형개거리에 관한 연구)

  • Jung, Hyun-Suk;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.56-61
    • /
    • 2021
  • The increase in automation facilities in the injection molding industry is a very important process control item. The most important item when constructing an unmanned machine using a take-out robot is the "mold opening stroke" of the mold. The injection molding machine control method is divided into hydraulic type and electric type, and there have been few studies on the mold opening distance according to the control method. In this study, the correlation was confirmed by increasing the injection speed to 20, 50, 80, and 100% for the three types of hydraulic control method, open loop and close loop, and electric control method. Through the experiment, the following results were obtained. (1) It can be seen that the reproducibility is excellent with the electric, close loop, and open loop control methods. (2) When the injection speed is set to 50%, the mold opening distance is 263.10~263.27 mm, which is the most reproducible. (3) As a result of ANOVA, both injection speed and mold opening distance showed a significant difference in the hydraulic control method (p<0.05), but it was verified through experiments that there was no significant difference in the electric control method. Based on these results, when electric control is selected rather than hydraulic control, the reproducibility of the mold opening distance is excellent, so it is thought that the taking-out robot can take the object out of the mold more safely.

Effect of Hydrothermal Reaction Conditions on Piezoelectric Output Performance of One Dimensional BaTiO3 Nanotube Arrays (1차원 BaTiO3 나노튜브 어레이의 압전발전성능에 수열합성 반응조건이 미치는 영향)

  • Lee, Jae Hoon;Hyeon, Dong Yeol;Heo, Dong Hun;Park, Kwi-Il
    • Journal of Powder Materials
    • /
    • v.28 no.2
    • /
    • pp.127-133
    • /
    • 2021
  • One-dimensional (1D) piezoelectric nanostructures are attractive candidates for energy generation because of their excellent piezoelectric properties attributed to their high aspect ratios and large surface areas. Vertically grown BaTiO3 nanotube (NT) arrays on conducting substrates are intensively studied because they can be easily synthesized with excellent uniformity and anisotropic orientation. In this study, we demonstrate the synthesis of 1D BaTiO3 NT arrays on a conductive Ti substrate by electrochemical anodization and sequential hydrothermal reactions. Subsequently, we explore the effect of hydrothermal reaction conditions on the piezoelectric energy conversion efficiency of the BaTiO3 NT arrays. Vertically aligned TiO2 NT arrays, which act as the initial template, are converted into BaTiO3 NT arrays using hydrothermal reaction with various concentrations of the Ba source and reaction times. To validate the electrical output performance of the BaTiO3 NT arrays, we measure the electricity generated from each NT array packaged with a conductive metal foil and epoxy under mechanical pushings. The generated output voltage signals from the BaTiO3 NT arrays increase with increasing concentration of the Ba source and reaction time. These results provide a new strategy for fabricating advanced 1D piezoelectric nanostructures by demonstrating the correlation between hydrothermal reaction conditions and piezoelectric output performance.

Clinical outcomes of bending versus non-bending of the plate hook in acromioclavicular joint dislocation

  • Joo, Min Su;Kwon, Hoi Young;Kim, Jeong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.202-208
    • /
    • 2021
  • Background: We aimed to assess the effect of plate hook bending in treatment of acromioclavicular (AC) dislocation by analyzing clinical and radiological results according to the angle of the plate hook (APH). Methods: This was a retrospective, observational, case-control study including 76 patients with acute AC joint dislocation that were divided into two groups according to treatment with bent or unbent plate hook. The visual analog scale (VAS), the American Shoulder and Elbow Surgeons (ASES) shoulder score, and range of motion (ROM) were evaluated as clinical outcomes. Comparative coracoclavicular distance (CCD) was measured to evaluate radiological outcomes. Results: While the VAS and ASES of the bending group at 4 months after surgery were significantly higher (p=0.021 and p=0.019), the VAS and ASES of the bending group at other periods and ROM of the bending group showed no significant difference. The initial CCD decreased from 183.2%±25.4% to 114.3%±18.9% at the final follow-up in the bending group and decreased from 188.2%±34.4% to 119.1%±16.7% in the non-bending group, with no statistical difference (p=0.613). The changes between the initial and post-metal removal CCD were 60.2%±11.2% and 57.3%±10.4%, respectively, with no statistical difference (p=0.241). The non-bending group showed greater subacromial osteolysis (odds ratio, 3.87). Pearson's coefficients for the correlation between APH and VAS at 4 months after surgery and for that between APH and ASES at 4 months after surgery were 0.74 and -0.63 (p=0.027 and p=0.032), respectively. Conclusions: The APH was associated with improved postoperative pain and clinical outcomes before implant removal and with reduced complications; therefore, plate hook bending is more useful clinically during plate implantation.

Optimization of VIGA Process Parameters for Power Characteristics of Fe-Si-Al-P Soft Magnetic Alloy using Machine Learning

  • Sung-Min, Kim;Eun-Ji, Cha;Do-Hun, Kwon;Sung-Uk, Hong;Yeon-Joo, Lee;Seok-Jae, Lee;Kee-Ahn, Lee;Hwi-Jun, Kim
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.459-467
    • /
    • 2022
  • Soft magnetic powder materials are used throughout industries such as motors and power converters. When manufacturing Fe-based soft magnetic composites, the size and shape of the soft magnetic powder and the microstructure in the powder are closely related to the magnetic properties. In this study, Fe-Si-Al-P alloy powders were manufactured using various manufacturing process parameter sets, and the process parameters of the vacuum induction melt gas atomization process were set as melt temperature, atomization gas pressure, and gas flow rate. Process variable data that records are converted into 6 types of data for each powder recovery section. Process variable data that recorded minute changes were converted into 6 types of data and used as input variables. As output variables, a total of 6 types were designated by measuring the particle size, flowability, apparent density, and sphericity of the manufactured powders according to the process variable conditions. The sensitivity of the input and output variables was analyzed through the Pearson correlation coefficient, and a total of 6 powder characteristics were analyzed by artificial neural network model. The prediction results were compared with the results through linear regression analysis and response surface methodology, respectively.

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

A Study on the Heavy Metals Concentrations in the Air of the Dental Laboratories, in the Blood and Urine of Dental Laboratory Technicians (치과기공실 공기중 및 치과기공사의 혈액, 요중 중금속 함량에 관한 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 1988
  • The purpose of this study was to determine the concentration of cadmium, nickel and chromium in the air of the work-place, blood of and urine of workers and compare the level of those heavy metals by the duration of work, work-place, process of work, smoking and other factors. In this study, 48 male dental laboratory technicans and 72 office workers as the control group were subjected. The concentration of cadmium, nickel and chromium in their blood sand urine, and that of heavy metals in the air of their work-rooms were examined and analyzed from June I 1987 to September 30, 1987. The results were as follows : 1. The concentration of cadmium in the air was the highest in the porcelain part, $0.0087{\pm}0.0016mg/m^3$, that of nickel was the highest in the crown bridge part, $0.4253{\pm}0.0052mg/m^3$, and that of chrnmium was highest in the partial denture part, $0.1063{\pm}0.0024mg/m^3$. 2. cadmium, nickel and chromium concentrations in the blood and urine of dental laboratory techincians were higher that in the office workers'. Especially the concentration of cadmium in the blood($1.92{\pm}1.23{\mu}g$/100ml) of th dental laboratory techician was about two times as high as that in the office workers'($0.90{\pm}0.73{\mu}g$/100ml), and the concentration of nickel in the urine($48.53{\pm}38.83{\mu}g$/e) of the dental laboratory thchnician was about two times as high as that in the office worker's($20.24{\pm}15.35{\mu}g$/e). 3. there was no difference in the concentration of cadmium, nickel and chromium in the blood and urine with a longer duration of work. 4. The concentration of cadmium and chromium in the blood and urine differed significantly depending upon the place of work. The concentration of cadmium was the highest in the blood of dental laboratory technicians working kin the poreclain part marking at $2.53{\pm}1.08{\mu}g$/100ml. The chromium level was the heighest in the blood of partial denture park workers with a concentration of $3.60{\pm}1.02{\mu}g$/100ml. Concerning the level of cadmium in urine, it was the highest in the porcelain part workers with a concentration of $3.41{\pm}3.15{\mu}g$/e. 5. The concentration of cadmium in the urine of metal trimming and polishing group($2.64{\pm}2.41{\mu}g$/e) was higher than that of non-metal trimming and polishing group($1.39{\pm}1.18{\mu}g$/e). 6. The concentration of chromium in the blood of smoking group($2.46{\pm}1.54{\mu}g$/100ml)was higher than that lf non-smoking group($1.54{\pm}1.25{\mu}g$/100ml). 7. The height positive correlation coefficient was shown between the concentration of nickel and chromium in the blood among the all correlations between 3metals(Cd, Ni, Cr) in the blood and those in urine. The correlation coefficient was relatively high(r=0.605,,p<0.01). In general, the higher the concentration of heavy metals in the air of work places the higher the concention lf them in the blood and urine of workers, mere attention should be paid to the working environment of dental laboratory workers, Furthermore, continuous biological monitoring and further research are required for an efficient health management for dental laboratory workers.

  • PDF

Geochemical Characteristics and Heavy Metal Pollutions in the Surface Sediments of Oyster Farms in Goseong Bay, Korea (고성만 굴 양식장 표층퇴적물의 지화학적특성과 중금속 오염에 관한 연구)

  • Kang, Ju-Hyun;Lee, Sang-Jun;Jeong, Woo-Geon;Cho, Sang-Man
    • The Korean Journal of Malacology
    • /
    • v.28 no.3
    • /
    • pp.233-244
    • /
    • 2012
  • Goseong bay, located in southeast sea of Korea with an area of 2,100 ha, is a semi-enclosed bay well-known for oyster farming cultured in an extended range of 148 ha. The objective of this study is to provide the fundamental data in order to manage the effective sea area. A total 26 of surface sediment were collected from Goseong bay to evaluate their sedimentary environment and heavy metals. The loss on Ignition (LOI), C/N ratio, acid volatile sulfide (AVS) and heavy metals were analyzed. loss on ignition (LOI) of surface sediment range from 1.00% to 3.03% (average 2.00%). The carbonate content ranges from 0.52% to 4.29% (average 2.37%). C/N ratio of organic matter showed that most part of organic matter comes from neighboring continent. Acid volatile sulfide (AVS) value of surface sediment from 0.02 mg/g to 1.43 mg/g (average 0.24 mg/g). A ten element of surface sediments (Al, As, Cd, Cr, Cu, Hg, Ni, Pb, V, Zn) were calculated by enrichment factor (Ef) and the results show that some areas are highly polluted with respect Cu and Hg. The correlation matrix displays the existence of remarkable levels of correlation with both positive and negative values among different variable pairs. LOI and AVS showed both positive values. LOI and AVS values falls under 2% and 1%. Therefore, Goseong bay showed good in quality of sediment.

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.