• Title/Summary/Keyword: Metal color

Search Result 550, Processing Time 0.027 seconds

Studies on the Quality Evaluation and Metal Content of Sanitary Canned Kamju Beverage (위생캔으로 제조한 감주 음료의 품질 평가와 금속물질 함량에 관한 연구)

  • 허윤행
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.18-26
    • /
    • 2000
  • In order to improve the quality of Kamju(sikhae), Korean traditional sweat fermentated rice drink, Kamju made with laboratory fermenting from both covered barley malt and that added to commercial $\alpha-amylase$ and commercial sikhae can were investigated and analyzed ad follows 1. The amylase activities in L-malt(laboraory made malt), C-malt(commercial malt) were 25,065 units, 20,498 units at $60^{\circ}C$ and when heating at $60^{\circ}C$ for one hour their heat stability was getting lower and while at $70^{\circ}C$ after 2 hours both their heat stability was under 21%. 2. The external appearance, of all samples, in beating test, flipper, springer and leaker test were excellent and good valued. On the open test of sample can, head space was 7.9~9.0mm, net weight 247~250g, 432~435g, pH 4.96-5.76, Brix 13.2~14.0 and vacuum degree was 29~35cmHg. 3. The sucrose content of sample 1~5 was 8,57~10.01% highest ammount than sample 6(0.91%) 7(0.43%) and maltose content of sample 1~5 was 0.65~1.41% lower than 6 was 7.91% and 7 was 8,36%. The good traditional flavor texture and saccharides components content of glucose of sample 1~5 was 1.09~1.51, 6(3.86%), 7(3.97%), fructose content of sample 1~5 was 0.45~0.95%, 6(2.76%), 7(2.81%), maltotriose and raffinose of sample 1~5 were 0.04~0.291, 6(0.61%), 7(2.81%), and solid content of sample 1~5(3.1~3.8) was lower than 6(10.25%), 7(10.09%). 4. The result of sensory test as measured as lemone yellow of sample 6 and milky of sample 7, and weetness, flavor, color, traditional texture and sensory value for sample 1~5(3.1~3.8) was lower degree than that for 6(4.5), 7(4.0). 5. Among the heavy metals analyzed from sample cans, tin, iron and lead content for sample 1~5 were 31.95~36.71ppm, 5.84~6.39ppm and 0.075~0.09ppm while their content of sample 6.7, tin, 32.91ppm, 32.87ppm, iron 5.51ppm, 5.41ppm and lead, 0.074ppm, 0.079ppm.

  • PDF

Physicochemical Properties and Antioxidant Activities of High-Sugar Fermented Pinus koraiensis Cone Extract (잣송이 추출물의 이화학적 특성 및 항산화 활성)

  • Jang, Ki-Hyo;Surh, Jeonghee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.1
    • /
    • pp.140-145
    • /
    • 2017
  • Pinus koraiensis cone (PKC) extract was prepared by mixing PKC with sugar at a weight ratio of 1:1 and then removing PKC after incubating the mixture at room temperature for 100 days. The resulting PKC extract was examined for its physicochemical properties and antioxidant activities using Prunus mume fruit extract, which is similar to PKC extract in terms of preparation procedure and product usage, as a control. PKC extract consisted mainly of moisture (21.76%) and sugar (70.03%), leading to high viscosity. PKC extract was apparently yellowish, and therefore its browning index and color intensity were appreciably lower than the control (P=0.0000), indicating that Maillard reaction was not facilitated during fermentation. Compared with the control, PKC extract was not appreciably different in terms of total flavonoid content, whereas its organic acid content and total reducing capacity were significantly lower. Nevertheless, its metal-chelating activity and DPPH radical scavenging activity were comparable to those of the control. In addition, SOD-like activity of PKC extract was 2-fold higher than that of 6.6 mM quercetin, which had a higher total flavonoid content than PKC extract. This indicates that PKC extract contains certain flavonoids with higher antioxidant activities than quercetin. The results show that PKC extract provides antioxidant activity as well as characteristically different sensory properties due to its higher sugar and lower organic acid contents compared with Prunus mume fruit extract.

A Quality-control Experiment Involving an Optical Televiewer Using a Fractured Borehole Model (균열모형시추공을 이용한 광학영상화검층 품질관리 시험)

  • Jeong, Seungho;Shin, Jehyun;Hwang, Seho;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.17-30
    • /
    • 2020
  • An optical televiewer is a geophysical logging device that produces continuous high-resolution full-azimuth images of a borehole wall using a light-emitting-diode and a complementary metal-oxide semiconductor image sensor to provide valuable information on subsurface discontinuities. Recently, borehole imaging logging has been applied in many fields, including ground subsidence monitoring, rock mass integrity evaluation, stress-induced fracture detection, and glacial annual-layer measurements in polar regions. Widely used commercial borehole imaging logging systems typically have limitations depending on equipment specifications, meaning that it is necessary to clearly verify the scope of applications while maintaining appropriate quality control for various borehole conditions. However, it is difficult to directly check the accuracy, implementation, and reliability for outcomes, as images derived from an optical televiewer constitute in situ data. In this study, we designed and constructed a modular fractured borehole model having similar conditions to a borehole environment to report unprecedented results regarding reliable data acquisition and processing. We investigate sonde magnetometer accuracy, color realization, and fracture resolution, and suggest data processing methods to obtain accurate aperture measurements. The experiment involving the fractured borehole model should enhance not only measurement quality but also interpretations of high-resolution and reliable optical imaging logs.

PEMOCVD of Ti(C,N) Thin Films on D2 Steel and Si(100) Substrates at Low Growth Temperatures

  • Kim, Myung-Chan;Heo, Cheol-Ho;Boo, Jin-Hyo;Cho,Yong-Ki;Han, Jeon-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.211-211
    • /
    • 1999
  • Titanium nitride (TiN) thin films have useful properties including high hardness, good electrical conductivity, high melting point, and chemical inertness. The applications have included wear-resistant hard coatings on machine tools and bearings, decorative coating making use of the golden color, thermal control coatings for widows, and erosion resistant coatings for spacecraft plasma probes. For all these applications as feature sizes shrink and aspect ratios grow, the issue of good step coverage becomes increasingly important. It is therefore essential to manufacture conformal coatings of TiN. The growth of TiN thin films by chemical vapor deposition (CVD) is of great interest for achieving conformal deposition. The most widely used precursor for TiN is TiCl4 and NH3. However, chlorine impurity in the as-grown films and relatively high deposition temperature (>$600^{\circ}C$) are considered major drawbacks from actual device fabrication. To overcome these problems, recently, MOCVD processes including plasma assisted have been suggested. In this study, therefore, we have doposited Ti(C, N) thin films on Si(100) and D2 steel substrates in the temperature range of 150-30$0^{\circ}C$ using tetrakis diethylamido titanium (TDEAT) and titanium isopropoxide (TIP) by pulsed DC plamsa enhanced metal-organic chemical vapor deposition (PEMOCVD) method. Polycrystalline Ti(C, N) thin films were successfully grown on either D2 steel or Si(100) surfaces at temperature as low as 15$0^{\circ}C$. Compositions of the as-grown films were determined with XPS and RBS. From XPS analysis, thin films of Ti(C, N) with low oxygen concentration were obtained. RBS data were also confirmed the changes of stoichiometry and microhardness of our films. Radical formation and ionization behaviors in plasma are analyzed by optical emission spectroscopy (OES) at various pulsed bias and gases conditions. H2 and He+H2 gases are used as carrier gases to compare plasma parameter and the effect of N2 and NH3 gases as reactive gas is also evaluated in reduction of C content of the films. In this study, we fond that He and H2 mixture gas is very effective in enhancing ionization of radicals, especially N resulting is high hardness. The higher hardness of film is obtained to be ca. 1700 HK 0.01 but it depends on gas species and bias voltage. The proper process is evident for H and N2 gas atmosphere and bias voltage of 600V. However, NH3 gas highly reduces formation of CN radical, thereby decreasing C content of Ti(C, N) thin films in a great deal. Compared to PVD TiN films, the Ti(C, N) film grown by PEMOCVD has very good conformability; the step coverage exceeds 85% with an aspect ratio of more than 3.

  • PDF

Manufacture of paste opaque porcelains using glycols as a solvent and evaluation of their physical properties (글리콜을 용매로 제조한 연고형 불투명 도재의 물성)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.41-62
    • /
    • 2003
  • In this research, we manufactured the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent, and compared the composition of solvents, the coefficient of thermal expansion, the particle size distribution, the viscosity and bonding strength to metal, and the tone with those of the commercial products(Duceram Plus, Duceram GmbH; VMK 95, Vita Co.; Noritake EX-3, Noritake Co.)used in the clinical field. The results of the research were as follows: 1. The result of solvent analysis indicated that the solvents included in the paste opaque porcelains of the control group were mainly composed of Glycols. 2. From the Coefficient of thermal expansion measurement, we drew out the following results; testing group: $14.0\times10^{-6}/^{\circ}C$, Duceram Plus: $13.9\times10^{-6}/^{\circ}C$, VMK 95: $14.3\times10^{-6}/^{\circ}C$, and Noritake EX-3: $13.3\times10^{-6}/^{\circ}C$. 3. Seen from the result of particle size distribution measurement, the experimental group was similar to the control group in 1$\mu m$ below, but the experimental group marked the highest distribution of 61% in the case of between 1$\mu m$ and 5$\mu m$. Between 5$\mu m$ and 10$\mu m$, they showed relatively similar distribution, and Noritake EX-3 was turned out the highest distribution of 29% in 10$\mu m$ above. 4. From the result of viscosity measurement, Duceram plus showed the highest viscosity throughout all the measurements followed by Noritake Ex-3, experimental group and VMK 95 in decreasing order. 5. The result of bonding strength measurement was EX 35.53 $\beta\acute{A}$, DU 40.88 $\beta\acute{A}$, VM 39.43 $\beta\acute{A}$, and NO 35.39 $\beta\acute{A}$, and no significant difference was found between the experimental group and the control groups(P>0.05). 6. The measurement of the tone indicated that the $L^*$ value of the experimental group was 86.89 0.63 in average, which is higher than the control group in its brightness. In the case of the $a^*$ value, Duceram Plus, VMK 95 and EX-3 showed positive value, whereas the testing group was turned out negative value. In $b^*$ value, Duceram Plus proved the highest. From the results of this research, the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent did not make differences from the commercial products that are actually used in the clinical fields. Therefore, it is possible to utilize Propylene Glycol (PG) and Buthylene Glycol (BG) for the paste opaque porcelains of P.F.M crown. It is also recommended that further researches concerning the compositions and forms of powder, the types of organic solvent components and the ratio of mixture proceeded in order to improve the level of productivity in the future.

  • PDF

A Study on the Characteristics of Smartphone Camera as a Medical Radiation Detector (의료 방사선 검출기로써 스마트폰 카메라의 특성에 관한 연구)

  • Kang, Han Gyu;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.143-151
    • /
    • 2016
  • The aim of this study is to investigate the optimal algorithm to extract medical radiation induced pixel signal from complementary metal-oxide semiconductor (CMOS) sensors of smartphones camera. The pixel intensity and pixel number of smartphone camera were measured as the X-ray dose was increased. The front camera of the smartphone camera has low noise property and excellent dose response as compared to the back camera of the smartphone. The indirect method which uses scintillation crystal in front of the smartphone camera, couldn't improve the X-ray detection efficiency as compared to the direct method which does not use any scintillator in front of the smartphone camera. When we used the algorithm which employing threshold level on the pixel intensity and pixel number, the dose linearity was more higher for the pixel intensity rather for the pixel number. The use of pixel intensity of Y color component which represents the grey scale, would be efficient in terms of the radiation detection efficiency and reducing the complexity of the image processing. We expect that the radiation dose monitoring can be managed effectively and systematically by using the proposed radiation detection algorithm, thus eventually will contribute to the public healthcare.

Full-mouth rehabilitation with pressed ceramic technique using provisional restorations (Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례)

  • Roh, Hyun-Sik;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • With the introduction of dental implants, restoration of missing teeth with conventional fixed or removable partial dentures is being replaced with implants. Especially, with young patients, not only longevity but also esthetic factors need to be considered. Implant restorations provide long-term success functionally but, esthetic complications such as, marginal exposure due to gingival recession, loss of the papilla and dark color of metal abutments may occur. Recently, zirconia restorations with CAD/CAM technology provide functional, biocompatible and esthetic restorations possible. All-ceramic restorations using the pressed ceramic technique show better fracture toughness values than those of the conventional porcelain veneering technique. Pressed ceramic technique creates the veneer design in wax and the lost wax technique is used to create the restoration. The final contour of the restoration may be controlled during wax-up. A 22-year old female patient was restored with dental implants and zirconia restorations using the pressed ceramic technique presenting short-term but optimistic prognosis.

To Compare and Analyze Costumes in the Film "The Great Gatsby" and Y&Kei Collection (영화 "The Great Gatsby" 의상과 Y&Kei 컬렉션 비교 분석)

  • O, Ji-Hye;Lee, In-Seong
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.6
    • /
    • pp.1050-1063
    • /
    • 2008
  • A movie is a fiction made on a basis of an author's and a writer's imagination, but all sorts of properties mixed with each other and most realistically expresses the era which becomes the background of a movie and acts as a carrier that connects designers with consumers. Thus, this study was carried out to review how the fashion products that designer's intention and commercial value added are expressed in collections by comparing and analysing the costumes in the movie "The Great Gatsby" that described the life of America's upper-class in 1920s and the 04 S/S Y&Kei collection which were proceeding after getting inspiration from this movie. For this, literature materials were inspected in order to make a theoretical review on social and cultural background and costumes history background in 1920s and the photo materials on movie costume were collected and analysed using DVD video captures, as well as the photo materials on 04 S/S Y&Kei were collected and analyzed through the institute providing domestic fashion information. The following conclusion was deduced through this study. First, in 1920s which becomes the background of this study, the slim shape of Flapper which looks like a young and boy became an ideal figure condition and the straight silhouette with low waist line and the short skirt that rose to knee was popular. Second, as a result of analysing movie costume by classifying it in silhouette, colors, and materials, straight silhouette of low waistline with a near colored - tone seen in the pastel series, including white, beige, pink, and gray was mainly constituted and the metal colors like silver and gold were used. As a material, chiffon, satin, velvet, flower patterned prints, and beads were used, which represented luxurious life of women in the upper classes. Third, as a result of comparing and analysing, it turned out that there was a similarity. However, in dress collection for a heroine, some dissimilarity differentiated from a movie costumes was found out in that the dresses in collection expressed moderate beauty and modernism and elegant beauty at the same time by matching a variety of materials and using black color.

  • PDF

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Chemical Cleaning of Iron Stains on Ceramics (화학세척제를 이용한 도자기의 철산화물 제거 특성 연구)

  • Park, Dae-Woo;Jang, Sung-Yoon;Nam, Byeong-Jik;Ham, Chul-Hee;Lim, Seong-Tae
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.345-356
    • /
    • 2011
  • To remove metal stains of the ceramics, chemical cleaning is essential case by case. This study investigated the removal characteristics of iron stains by oxalic acid and citric acid including their application methods of soaking and poultice. The soaking method in cleaning agents showed removal process by color difference and released iron contents from iron stains on ceramics. Iron stains were removed successfully from ceramics, which soaked in oxalic acid for 60 hours. However, it is recommendable to soak in 0.25M oxalic acid for one to three hours because most iron stains were disappeared in 3 hours soaking. Citric acid is less effective than oxalic acid in removing iron stains because of heavy molecular weight and low acidity. Poultices (bentonite, sepiolite, activated carbon fiber and celite) with oxalic acid were applied on contaminated ceramics. After ten hours, iron stains on ceramics were removed successfully by poultice. Among them, bentonite and sepiolite have better application. Therefore, sepiolite with 0.25M oxalic acid was applied on the iron stains of whiteware and celadon from Ma Island, and then stains were removed. However, it is judged that the application methods can be varied according to the form and depth of contaminant. In addition, the residues of poultice on the ceramics will be considered for preventing contamination.