• Title/Summary/Keyword: Metal color

Search Result 550, Processing Time 0.026 seconds

Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

  • Suputtamongkol, Kallaya;Tulapornchai, Chantana;Mamani, Jatuphol;Kamchatphai, Wannaporn;Thongpun, Noparat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.319-325
    • /
    • 2013
  • PURPOSE. The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS. Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at ${\alpha}$=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS. $L^*$, $a^*$, and $b^*$ values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ${\Delta}E{^*}_{ab}$ values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION. No significant differences were observed between the $L^*$, $a^*$, and $b^*$ values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ${\Delta}E{^*}_{ab}$ values.

Preparation of Dithizone Functionalized Polystyrene for Detecting Heavy Metal Ion (중금속 검지를 위한 디티존 기능화된 폴리스티렌 제조)

  • Shin, Hyeon Ho;Kim, Younghun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.243-246
    • /
    • 2015
  • Colorimetric sensors were usually used to detect specific metal ions using selective color change of solutions. While almost organic dye in colorimetric sensors detected single molecule, dithizone (DTZ) solution could be separately detected above 5 kinds of heavy metal ions by the change of clear color. Namely, DTZ could be used as multi-colorimetric sensors. However, DTZ was generally used as aqueous type and paper/pellet-type DTZ was not reported yet. Therefore, in this work, polystyrene (PS) was prepared to composite with DTZ and then DTZ/PS pellet was obtained, which was used to selectively detect 10 kinds of heavy metal ions. When 10 ppm of Hg and Co ions was exposed in DTZ/PS pellets, clear color change was revealed. It is noted that DTZ/PS pellet could be used in detecting of heavy metal ion as dry type.

Color Evolution in Single Crystal Colored Cubic Zirconias With Annealing Atmosphere and Temperature

  • Song, Jeongho;Noh, Yunyoung;Song, Ohsung
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.450-455
    • /
    • 2016
  • Color change in single-crystal, yellow, red, purple, and colorless cubic zirconias (CZs) was investigated as a function of annealing in vacuum and air atmosphere at $800-1400^{\circ}C$ for 30 min, for development of a damascene process of plugging a precious metal paste at the elevated temperature. Coloring-element contents of the CZs were evaluated using WD-XRF, and the color change determined visually by naked eye, and using a digital camera and UV-Vis-NIR color analyzer. WD-XRF showed that all of the CZs had cubic-phase stabilizer elements and coloring elements. All CZs that underwent vacuum annealing exhibited a slight color change at $<900^{\circ}C$, while their colors began to change to black at $1100^{\circ}C$, and became opaque black at $1400^{\circ}C$. After air annealing, there was almost no color change up to $1400^{\circ}C$. Since red and purple CZs showed greater color difference (CD) values than the others, the degree of CD is likely to depend on the original color of the CZ due to the different stabilities of their coloring elements during annealing. Based on our results, it is suggested that annealing in air at $<900^{\circ}C$ is advantageous, and assorted colored CZs can be used for precious metal damascene.

The Effect of Repeated Firing on the Color Difference of a Metal-Ceramic System with Different Porcelain Powder (다른 특성을 가지는 도재가 반복소성에 따라 색조변화에 미치는 영향)

  • Hwang, Jae-Sun
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.23-36
    • /
    • 2009
  • The goal of esthetic restoration is to achieve morphologic, optical, and biologic acceptance. Creation of a natural looking ceramic restoration, which blends harmoniously with surrounding dentition, is not always achieved. A successful color match is an important aspect of any esthetic dental restoration. Since natural enamel has inherent translucency, it is important that ceramic restorations reproduce the translucency and color of the natural teeth. However, the final color match of porcelain crowns to adjacent natural dentition remains some problem. Difficulties related to color matching arise from the structural differences that exist between metal ceramic crowns and natural teeth, the limited range of available ceramic shades, inadequate shade guides, different types of metal alloys, repeated firing, the condensation technique, and varying compositions of ceramic materials. Many factors contribute to the esthetic success of dental restoration: optical properties such as color and its elements of hue, value, and chroma; translucency and opacity; light transmission and scattering; and metamerism and fluorescence. The purpose of this study was to determine the color changes of metal-ceramic system with different veneering porcelain powder after repeated firing. The objectives of this in vitro study were to measure the lightness($L^*$), chromaticity($a^*$), chromaticity($b^*$), chroma($C^*$), hue(h), reflectance(%), color difference(${\Delta}E$). The following conclusions were obtained: 1. An increase in the number of firings resulted in decrease in lightness($L^*$) but increase in chromacticity($a^*$) with all porcelain. After the second sintering resulted in decrease in chromacticity($b^*$) with opaque-dentin porcelain and dentin porcelain but in increase with enamel porcelain and translucency porcelain. And after the second sintering resulted in decrease in chroma($C^*$) with opaque-dentin porcelain and dentin porcelain, but on the whole side in decrease with enamel porcelain and translucency porcelain. 2. After the second firing, a increase in the number of firings resulted in decrease reflectance(%) in all wavelength. 3. There were noticeable color differences(${\Delta}E$) between first sintering and multiple firings(dentin porcelain: 5.29~8.15, opaque-dentin porcelain: 4.83~8.2, enamel porcelain: 8.93~13.15, translucency porcelain: 9.37~12.91), but the color difference(${\Delta}E$) after second sintering were down to 4.87 in all porcelain. 4. Given the NBS Criteria, a 'trace' was not found this study but a 'slight' was found 2-3, 3-5 in dentin porcelain, 2-3 in opaque-dentin porcelain, 3-5, 5-10 in enamel porcelain and translucency porcelain, a 'noticeable' was 2-5, 3-10, 5-10 in dentin porcelain and opaque-dentin porcelain, 2-3, 2-5, 3-10 in enamel porcelain 2-3, 3-10 in translucency porcelain, an 'appreciable' was 1-2, 1-3, 2-10 in dentin porcelain 1-2, 1-3, 2-10, 3-10 in opaque-dentin porcelain, 2-10 in enamel porcelain, 2-5, 2-10 in translucency porcelain, a 'much' was 1-5, 1-10 in dentin porcelain and opaque-dentin porcelain, 1-2, 1-3, 1-5 in enamel porcelain 1-2, 1-3, 1-5, 1-10 in translucency porcelain, a 'very much' was 1-10 in enamel porcelain.

  • PDF

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

  • Jang, Dae-Eun;Lee, Ji-Young;Jang, Hyun-Seon;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.278-287
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

Correlation between optimized thicknesses of capping layer and thin metal electrode for efficient top-emitting blue organic light-emitting diodes

  • Hyunsu Cho;Chul Woong Joo;Byoung-Hwa Kwon;Chan-mo Kang;Sukyung Choi;Jin Wook Sin
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1056-1064
    • /
    • 2023
  • The optical properties of the materials composing organic light-emitting diodes (OLEDs) are considered when designing the optical structure of OLEDs. Optical design is related to the optical properties, such as the efficiency, emission spectra, and color coordinates of OLED devices because of the microcavity effect in top-emitting OLEDs. In this study, the properties of top-emitting blue OLEDs were optimized by adjusting the thicknesses of the thin metal layer and capping layer (CPL). Deep blue emission was achieved in an OLED structure with a second cavity length, even when the transmittance of the thin metal layer was high. The thin metal film thickness ranges applicable to OLEDs with a second microcavity structure are wide. Instead, the thickness of the thin metal layer determines the optimized thickness of the CPL for high efficiency. A thinner metal layer means that higher efficiency can be obtained in OLED devices with a second microcavity structure. In addition, OLEDs with a thinner metal layer showed less color change as a function of the viewing angle.

Color Stability of the Bioplastic containing Sorghum Extract Chelated by Fe(II) and Cu(II) (Fe(II)와 Cu(II)에 의해 킬레이트화 된 수수추출물 함유 바이오플라스틱의 색상 안정성)

  • Lee, Ga Hyun;Lee, Sung June;Jeong, Sang Won;Kim, Hyun-Chul;Choi, Jin Hyun;Bae, Do Gyu;Han, Sang Ik;Lee, Se Geun
    • Textile Coloration and Finishing
    • /
    • v.27 no.1
    • /
    • pp.62-69
    • /
    • 2015
  • To improve the color stability of the bioplastic containing sorghum extract, sorghum extract was chelated by a metal ion. The chelating activity was quantitatively evaluated under the various conditions. Chelation of sorghum extract by Cu(II) was determined by reaction with pyrocatechol violet, whereas Fe(II) chelation was investigated by forming complexes with ferrozine. Chelation of sorghum extract was increased rapidly with increasing concentrations of metal salt and sorghum extract. At a 0.1g/L metal salt addition level, the chelating activity of Fe(II) and Cu(II) were 66.7% and 54.2%, respectively. According to the chelation pH conditions, the sorghum extract was chelated almost 100% by Fe(II) above the pH 6.5. It was confirmed that Fe(II) was a strong chelator of sorghum extract than Cu(II). The sorghum extract chelated with metal salt exhibit higher thermal stability. The bioplastic containing chelated sorghum extract showed relatively less color change than the control.

EFFECT OF SECOND GENERATION POPULATIONS ON THE INTEGRATED COLOR OF METAL-RICH GLOBULAR CLUSTERS IN EARLY-TYPE GALAXIES

  • Chung, Chul;Lee, Sang-Yoon;Yoon, Suk-Jin;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.30.2-30.2
    • /
    • 2013
  • The mean color of globular cluster (GCs) systems in early-type galaxies (ETGs) is, in general, bluer than the integrated color of field stars in their host galaxies. Recently, Goudfrooij & Kruijssen (2013) reported that even red GCs in the ETGs show bluer colors than their host field stars and suggested the different initial mass function (IMF) for red GCs and field stars to explain the observed offset in color. Here we suggest an alternative scenario that explains the observed color offsets between red GCs in ETGs and the field stars in the parent galaxies without invoking to the variation of the IMF. We find that the inclusion of second-generation (SG) helium-enhanced populations in the model fully explains the observed color offset between red GCs and field stars in the host galaxies. We have also tested the effect of the IMF slope on our models, but the effect is relatively small compared to the effect of the SG population. Our new model suggests that, in order to explain far-UV strong metal-rich GCs in M87 and the observed color offset between metal-rich GCs and the field stars in ETGs simultaneously, the inclusion of the SG populations with enhanced helium abundance is a more natural solution than the model that only adopted variations in the IMF.

  • PDF

A Study on the Sensibility Evaluation on the Color Temperatures of Electrodeless HID Lamp (무전극 HID 램프의 색온도 감성평가에 관한 연구)

  • Pak, Hyensou;Park, Bonjour;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.9-15
    • /
    • 2014
  • An experiment was carried out to evaluate the emotion and sensibility evoked from the different color temperatures(CCT) of electrodeless HID (ELHID) lamp. For this purpose, three ELHID lamps and a metal halide lamp were used as the experimental light sources and thirty Korean adjectives related to the lighting affectiveness were selected for the evaluation. The results showed that ELHID lamps induced different sensibilities according to their color temperature. In particular, 6500 K ELHID was similar to metal halide which has the CCT of 5600 K in the evaluation. Based on the results, we suggested some Korean adjectives and their corresponding English ones which are thought to be suitable for the verbal descriptions of ELHID lamps.

Technical Trend of Plating & Surface Treatment for Eco-environment (친환경 도금표면처리 기술동향)

  • Kang, Kae-Myung;Kim, Yu-Sang
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.6
    • /
    • pp.301-310
    • /
    • 2009
  • Recently, it has been increasing for the eco-environment plating and surface treatment of eco-environment to decrease hazardous materials. Particular eco-environment can be applied to electronics or automotive parts of industry. In the case of mobile phone, if there were fired, the products bearing dye may be contaminated with the hazardous and wasted. we can obtain the original metal color by electro coloring by metal salt, get rid of hazardous gas, decrease the wasted sludges. Now, the industrial patent number is increasing in Korea, we can accomplish the development of green industry by supporting technical trend of the plating and surface treatment in eco-environment.